Contact the closest office: 1-800-358-5525

   Yokogawa Analog Panel Meters

 

Horizon Line AC Voltmeters/Ammeters, DC Voltmeters/Ammeters, AC Motor Load Indicators, & AC Frequency Meters --

  • Accuracy: All DC and AC iron-vane; ±2% of full-scale. AC rectifier type; ±3% of full scale (with 60 Hz sine wave at 25°C). When standard 60Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. 75%) may be experienced. Expanded-scale voltmeters; ±.5% of full scale value 
  • All meters meet ANSI Specifications C-39.1 
  • Overload: Voltmeters (AC and DC) -50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours 
  • Scale Data: 90 degree rotation 
  • Insulation Level: All meters (except 1 1/2"), 2600 VRMS Hi-pot, 1 1/2"-1500 VRMS Hi-pot 
  • Burden Data: AC ammeter-5 Amps, 0.5 va, max. 0.5 power-factor lagging. AC voltmeter-unity power factor 
  • Response Time and Overshoot: Response time: 3 seconds (max.) for 2 1/2", 3 1/2",4 1/2" size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 Seconds (max.) for AC ratings. Maximum of 40% overshoot 
  • Custom ranges and scaling are available 

Big Look AC Voltmeters/Ammeters, DC Voltmeters/Ammeters, AC Motor Load Indicators, & AC Frequency Meters --

  • Accuracy: All DC and AC iron-vane; ±2% of full-scale. AC rectifier type; ±3% of full scale (with 60 Hz sine wave at 25°C). When standard 60Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. 75%) may be experienced. Expanded-scale voltmeters; ±5% of full scale value.  All meters meet ANSI Specifications C-39.1
  • Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours 
  • Scale Data: 90 degree rotation 
  • Insulation Level: All meters (except 1 1/2"), 2600VRMS Hi-pot, 1 1/2"-1500VRMS Hi-pot 
  • Burden Data: AC ammeter-5 Amps, 0.5 VA, Max. 0.5 power-factor lagging; AC voltmeter - unity power factor 
  • Response Time and Overshoot: Response time: 3 seconds (max.) for 2 1/2", 3 1/2", 4 1/2" size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings. Maximum of 40% overshoot 
  • Custom ranges and scaling are available 


Type 185 Edgewise AC/DC Voltmeters/Ammeters --

  • Completely shielded, dust-tight case 
  • No special calibration required for panel material 
  • Stack mounting of meters is possible with all sides of meter case flush - Optional bezel/mounting bracket for 1-, 2-, or 3-unit stack (mounting hardware not included) 
  • Zero regulator provided in rear of case 
  • Accuracy: DC meters ±2% of full scale. AC rectifier type ±3% (60 Hz sine wave at 25°C) 
  • All meters meet ANSI Specification C-39.1 
  • Overload: Voltmeter: 50% momentary; 20% sustained Ammeter: 900% momentary. 20% sustained 
  • Scale Data: 53 degrees rotation. Length -1.785" 
  • Insulation Level: 1800 VRMS Hi-pot 
  • Response Time: 3 seconds (max.) for microammeters; 2 seconds (max.) for all other DC ratings; and 2.5 seconds (max.) for AC ratings 
  • Overshoot: Maximum of 40% 

Type 280 Thin Edgewise AC, DC Voltmeters/Ammeters --

  • Accuracy: ±2% of full scale, DC meters; ±3% with 60 Hz sine wave at 25šC for AC rectifier type meters 
  • Overload: DC voltmeters -20% momentary and sustained; DC ammeters (momentary) -10 times the rated current for 10 consecutive intervals of .5 second with 1 minute intervals between successive applications; DC ammeters (sustained) - 20% for 6 hours 
  • Dielectric (Hi-pot): 1500 VRMS for 1 1/2" and 2 1/2" sizes; 2600 VRMs for 3 1/2" size 
  • Response Time: 3 seconds max for meters, 2 seconds (max.) formA, A, mV, & V meters 
  • Pointer Color: red standard 
  • Bezel and Mounting Hardware included with meter 
  • Overshoot: 25% (max.) for 1 1/2" size, 40% (max.) for 2 1/2" and 3 1/2" sizes 
  • Scale Data: All three sizes designed for 53 degrees deflection. Scale lengths are: 1 1/2" size = 1.25", 2 1/2" size = 1.93", 3 1/2" size = 2.70". Note: All scales have linear distributions. 10V, 15V, 30V Rectifier scales will be non-linear 
  • All meters meet applicable sections of ANSI C39.1 
  • Custom ranges available 

Elapsed Time Meters --

  • New back-of-panel model 
  • 2 1/2" and 3 1/2" New Big Look models 
  • 2 1/2" and 3 1/2" round and square models 
  • UL recognition 
  • Conduit-case models available 
  • Optional 3 stud mounting available on 3 1/2" New Big Look type 240 meters 
  • Accuracy matches frequency control of power system 
  • Materials: clear Lexan case, Noryl frame, brass terminal studs, Lucite front covers 
  • Type 240 models available to operate on 120 or 208/240VAC, 50 or 60 Hz; and 480VAC, 60 Hz

About...  |  Table of Contents  | Manufacturer Index  | What's New

Send Inquiries to: