Signet pH and ORP Sensors
2714/2716 pH Electrodes --
- Submersible & in-line mounting capability
- Integrated temperature sensor
- Adapts with Signet 2720 Pre-amplifier
- Fits pipes from 0.5 to 4"
- Double-junction combination electrode
-
Construction Materials: CPVC with Viton® O-rings
- Junction Type: Annular double junction porous HDPE
- Response Time: 10 seconds for 98% of pH step change @ constant temp./pressure
- Temperature Range: 32 to 185°F (0 to 85°C)
- Temp. Compensation: Automatic from 32-212°F (0-100°C)
2715/2717 ORP Electrodes --
- Submersible and in-line mounting capability
- Double-junction combination electrode
- Junction Material: porous HDPE
- Adapts with Signet 2720 pre-amplifier
- Construction Materials: CPVC with Viton O-rings
- Junction Electrolyte: (front) KNO3 (rear) 4M KCI
- Electrode: Platinum Rod
- Reference Electrode: Ag/AgCI
2720 Pre-amplifier --
- Compatible with lntelek-Pro™ controllers and Compak transmitters
- Unique mV and TC element connector configuration
- Submersible or in-line mounting
- Chemically resistant CPVC housing
- Features a 15 ft. shielded cable and easy to connect 0.75" FNPT threads
- CPVC electronics enclosure
- Operating Temperature: -4-185°F (-20-85°C)
- Gain: X1 (unity)
- Input Power: ±4.5 to ±8 VDC Dual Supply
- Input Impedance: >10" Ohms
|