Contact the closest office: 1-800-358-5525

 

Newport Strain Gage Meters / Controllers

 i-Series 1/8 DIN Strain Gage Panel Meters and Controllers
 i-Series 1/32 DIN Strian Gage Panel Meter and Controllers

 Infinity Series 1/8 DIN Strain Gage Panel Meters

 Model 2003B 1/8 DIN Strain Gage Panel Meter


  -iS8 Series  ---

1/8 DIN Strain/Process Meters & Controllers

- 1/8 DIN

Buy It Now ! Ordering Info

  • Extended 5-year Warranty 
  •  High Accuracy, ±0.03% Rdg 
  •  Full Autotune PID Control (Optional) 
  •  User Friendly, Simple to Configure 
  •  Free Software, Active X Controls 
  •  Largest Display (21mm LED’s) of Any 1/8 DIN Instrument 
  •  Universal Inputs: Strain and Process Voltage/Current 
  •  First 1/8 DIN Instrument with Totally Programmable Color Displays (Standard) 
  •  First 1/8 DIN Instrument Offering Both RS-232 and RS-485 Serial Communications in One Instrument (Optional) 
  •  First 1/8 DIN Instrument with Built-in Excitation, 10 or 5 Vdc Standard 
  •  2 Control or Alarm Outputs (Optional)
    • dc Pulse
    • Solid State Relays (SSR's)
    • Mechanical Relays
    • Analog Voltage and Current 
  •  NEMA-4, IP65 Front Bezel 
iS800      Monitor only (no control outputs) 1/8 DIN
i8SL00    Monitor only (no control outputs) 1/8 DIN with 10pt. linearization 

CONTROL OUTPUTS #1 & #2 Direct (Cool) or Reverse (Heat) Acting 
iS8 (*) (*)     Two control outputs 1/8 DIN
i8SL (*) (*)   Two control outputs 1/8 DIN with 10 point linearization
(*) (*)
2 2 Two solid state relays (SSR's): 0.5 A @ 120/240 Vac continuous 
2 3 SSR and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac
2 4 SSR and pulsed 10 Vdc @ 20 mA (for use with external SSR) 
3 3 2 Relays: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac 
4 2 Pulsed 10 Vdc @ 20 mA (for use with external SSR) and SSR 
4 3 Pulsed 10 Vdc @ 20 mA (for use with external SSR) and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac 
4 4 Two pulsed 10 Vdc @ 20 mA (for use with external SSR) 
5 2 Analog Output selectable as either control or retransmission of process value; 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and SSR 
5 3 Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and Relay
5 4 Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and Pulse 10 Vdc

 NETWORK OPTIONS:
-EI Ethernet with Embedded Web Server
-C24 Isolated RS-232 and RS-485/422. 300 to 19.2k Baud *1
-C4EI Ethernet with Embedded Web Server + Isolated RS-485/422 hub for up to 31 devices *1

POWER SUPPLY :
* Standard power input: 90 to 240 Vac/dc, 50 to 400 Hz (no entry required)
-DC 12-36 Vdc, 24 Vac *1

FACTORY SETUP :
-FS Factory Setup and Configuration (requires -C24 Serial Communication option)

ORDERING EXAMPLE :

iS833 is a 1/8 DIN PID Controller with 2 relays
*1 -DC, -C24 or -C4EI not available with excitation.


  -iS32 Series  ---

1/32 DIN Strain/Process Meters & Controllers

- 1/32 DIN

Buy It Now ! Ordering Info

  • Extended 5-year Warranty 
  •  High Accuracy ±0.03% Rdg 
  •  Full Autotune PID Control (Optional) 
  •  User Friendly, Simple to Configure 
  •  Free Software, Active X Controls 
  •  Universal Inputs: Strain and Process Voltage/Current 
  •  First 1/32 DIN Instrument with Totally Programmable Color Displays (Standard) 
  •  First 1/32 DIN Instrument Offering Both RS-232 and RS-485 Serial Communications in One Instrument (Optional) 
  •  First 1/32 DIN Instrument with Built-in Excitation, 10 or 5 Vdc, Standard 
  •  2 Control or Alarm Outputs (Optional)
    • dc Pulse
    • Solid State Relays (SSR's)
    • Mechanical Relays
    • Analog Voltage and Current 
  •  NEMA-4, IP65 Front Bezel 
  •  Front Removable and Plug Connectors
iS3200   Monitor only (no control outputs) 1/32 DIN 

CONTROL OUTPUTS #1 & 2 Direct (Cool) or Reverse (Heat) Acting 
iS32 (*) (*)Two control outputs 1/32 DIN Strain or Process
 
(*) (*)
2 2 Two solid state relays (SSR's): 0.5 A @ 120/240 Vac continuous 
2 3 SSR and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac
2 4 SSR and pulsed 10 Vdc @ 20 mA (for use with external SSR) 
3 3 2 Relays: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac 
4 2 Pulsed 10 Vdc @ 20 mA (for use with external SSR) and SSR 
4 3 Pulsed 10 Vdc @ 20 mA (for use with external SSR) and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac 
4 4 Two pulsed 10 Vdc @ 20 mA (for use with external SSR) 
5 2 Analog Output selectable as either control or retransmission of process value; 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and SSR 
5 3 Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and Relay
5 4 Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and Pulse 10 Vdc

 NETWORK OPTIONS:
 
-IES Ethernet-Serial; Bridge/Hub
-C24 Isolated RS-232 and RS-485/422. 300 to 19.2k Baud *1

POWER SUPPLY :
 
* Standard power input: 90 to 240 Vac/dc, 50 to 400 Hz (no entry required)
-DC 12-36 Vdc, 24 Vac *1

FACTORY SETUP :
 
-FS Factory Setup and Configuration (requires -C24 Serial Communication option)

ORDERING EXAMPLE :

iS3222-C24 is a 1/32 DIN PID Controller with two solid state relays for PID control and serial communications, both RS-232 and RS-485

*1 -DC or -C24 not available with excitation. 


INFS  Strain Gage Meter  ---

Specifications 

  •  6 Digits 
  •  Optional Split Meter System 
  •  Four Isolated Open Collector Outputs 
  •  Wide Selection of dc Voltage and Current Ranges 
  •  Ratiometric Inputs 
  •  Tare 
  •  1.5 to 11 and 24 Vdc Sensor Excitation 
  •  Peak and Valley Detection and Memory 
  •  Large Digital Offset Capabilities Enabling Easy Scaling in Engineering Units 
  •  Smart Filtering Detects the Difference Between a Spike or Process Change (Patent Applied For) 
  •  Selectable Decimal Point and Read Rates of up to 13 Readings/Sec 
  •  Configurable Via Front Pushbuttons or Via RS-232 or RS-485 

Options 

  •  Isolated Dual 7 Amp Form C Relays 
  •  Isolated Parallel BCD Output 
  •  Isolated Analog Output 0-10 Vdc, 0-5 Vdc, 1-5 Vdc, 0-20 mA dc and 4-20 mA dc 
  •  Isolated Serial RS-232 
  •  Isolated RS-485, Addressable up to 199 Units 

 
MOST POPULAR MODEL :
INFS-0010-DC1 Strain gage indicator with analog output
 


INFCS-B  Strain Gage Meter  ---

Specifications 

  •  4-digit three color (Red, Green, Amber) Programmable LED display 
  •  Scaling in Wide Range of Engineering Units 
  •  Built-In Excitation 
  •  Analog Output Optional 
  •  Dual Relays Optional 
  •  Tare Button 
  •  Gross/Net Reading or Peak Reading Software Configurable 

 
To Order:

INFCS-( * )00 B  Digital Strain Meter with excitation, basic unit
INFCS-( * )01 B  Digital Strain Meter with non-isolated Analog output
INFCS-( * )10 B  Digital Strain Meter with dual (5-Amp from "C" relays )
INFCS-( * )11 B  Digital Strain Meter setpoint and non-isolated Analog output
INFCS-( * )12 B  Digital Strain Meter setpoint and isolated Analog output

Ordering Example: 
INFCS-010B, INFINITY® C strain meter with dual relays, red LED display, 115 Vac power

Power and Display Selection 

Order Code Power   Display
0 115 Vac Red
1 230 Vac Red
2 115 Vac Green
3 230 Vac Creen
4 10-32 Vdc Red
5 10-32 Vdc Green
6 26-56 Vdc Red
7 26-56 Vdc Green

Ordering Example: INFCS-011B, strain meter with 115 Vac power red LED display, analog output, dual relays


2003B Voltmeter for DC, AC RMS or Strain ---

STANDARD FEATURES 

  •  ­5,000 to +19,999-count display span 
  •  True-differential preamplifier 
  •  Isolated 5, 10, 15 Vdc excitation supply 
  •  2 Hz low-pass active filter, LA1 version 
  •  Peak-hold with external reset, LP1 version 
  •  1500 Vp CMV, 120 dB CMR 
  •  Parallel BCD output 
  •  0.1 mV/count analog output 
  •  Bright, 0.56 in (14.2 mm) LED display 
  •  115/230 V ac power 
  •  1/8 DIN case 

OPTIONS 

  •  NEMA-4 splash-proof lens cover 

About...  |  Table of Contents  | Manufacturer Index  | What's New

Send Inquiries to:

Copyright © 2009 Davis Instruments. All rights reserved.