Newport DIN-Rail Mount Signal Conditioners ---

Ordering Info
|
-
Models available for:
-
Strain
-
RTD
-
Thermocouple
-
AC Voltage & Current
-
Process Voltage & Current
-
Frequency / Pulse
-
Up to 1800 Vdc Isolation
-
DRN Series Provide 0-10 Vdc, 4-20 mA or 0-20 mA Output
-
DRX Series Provide RS-485 Output (Serial Protocol and
MODBUS Serial Protocol)
-
Free Setup and Configuration Software
-
Factory Setup and Configuration Available at No Charge (for DRN Analog
Output Models)
|
The DRN/DRX Series DIN rail mount signal conditioners represent state-of-the-art
signal conditioning technology, ideal for all process and power monitoring
applications. The intelligent microprocessor based modules provide
a wealth of features including high accuracy inputs, field programmable
ranges and 3-way electrical isolation. Models are available for most
process signals including thermocouples, RTDs process voltage, strain,
frequency, pulse, ac voltage and ac current measurement. Two base
styles are available, the DRN series which provides an output in an analog
voltage or current format, as well as RS-232, and the DRX series which
provides a digital RS-485 output.
DRN SERIES ANALOG OUTPUT
The DRN Series are the perfect front-end for a PLC or data acquisition
system. They feature an analog output signal which is directly proportional
to the input signal. The output, which is scalable, may be set for 0-10
V, 4-20 mA or 0-20 mA. The module is easily configured for different operating
parameters by connecting to a standard PC serial port and using the DRN-CONFIG
Windows-based software package. Once the module is configured, the parameters
are saved in non-volatile memory. The unit may be disconnected from the
PC and only needs to be connected to a PC again if an operating parameter
is to be changed.
DRX SERIES RS485 SERIAL OUTPUT
The DRX Series provide a complete sensor-to-computer solution. The
modules accept a variety of input signals and produce a RS-485 signal that
may be sent to a computer or virtually any other instrument containing
an RS-485 serial port. The DRX series may be used to create a comprehensive
distributed process monitoring network. Up to 32 modules may be interconnected
over a distance of 1200 m (4000 ft) on a single pair of wires. Through
the use of optional RS-485 repeaters, additional modules and distances
are easily accommodated. With repeaters, up to 254 modules may be connected
to a single RS-485 port. The modules feature a powerful, easy-to-use ASCII-based
command set. Because communication is accomplished by simply reading and
writing to and from the computer’s serial port, a program may be developed
using any language that provides serial port support. No special software
drivers or libraries are required.
SPECIFICATIONS :
Input Power Supply: 10 to 32 Vdc
DRX Output: 2-wire (half duplex) RS-485 (Omega® Serial Protocol
and Modbus Serial Protocol)
DRN Output: 0 to 10 V @ 10 mA max; 0 to 20 mA or 4 to 20 mA, 10 V compliance
Isolation: 1800 V peak
Typical Step Response to 99%: 1 second
Operating Ambient: -5 to 55°C (23 to 131°F)
Storage Temperature Range: -40 to 85°C (-40 to 185°F)
Mounting: 35 mm DIN rail
Dimensions: 75 x 22.5 x 151 mm (2.95 x 0.89 x 4.77")
Power Supplies :
24 Vdc Supply for DRN Modules
DRN-PS -1000 Switching Supply Powers up to 10 Units
INFINITY®SIGNAL
CONDITIONERS
RS-485
CONFIGURABLE WITH RS485 OUTPUT
|
Model
No.
|
PROCESS
VOLTAGE OR CURRENT DRX-PR |
|
DRX-PR
|
The
DRX-PR signal conditioner accepts process signal inputs within the spans
of 400mV, 1, 2, 5, 10V, and 20mA. Excitation of 10 or 14Vdc @ 20mA max.
is available for use with the input device. Accuracy is 0.1% with 13 bit
resolution and computer scalable via RS-485 using the DRX-CONFIG software
package. |
|
Model
No.
|
STRAIN
GAGE/BRIDGE OR MILLIVOLT |
|
DRX-ST
|
DRX-ST
The DRX-ST signal conditioner accepts strain gage/bridge or millivolt inputs
with ratiometric or absolute measurement. 10V excitation is standard. Input
spans of 30 or 100mV full scale. Accuracy is 0.1% with 13 bit resolution
and computer scalable via RS-485 using the DRX-CONFIG software package. |
|
Model
No.
|
THERMOCOUPLE
INPUT |
|
DRX-TC
|
DRX-TC
The DRX-TC signal conditioner accepts thermocouple types J, K, T, R, S,
B, N and J-DIN. The analog output is configurable for 0 to 10Vdc, 0 to
20mA or 4 to 20mA. Input and output configuration is via RS-485 using the
DRN-CONFIG software package. The DRX series features 3-way isolation to
1800V peak, ±1°C accuracy and resolution to 0.3°C above
-200°C. |
|
Model
No.
|
RTD
INPUT |
|
DRX-RTD
|
DRX-RTD
The DRX-RTD signal conditioner accepts 100, 500 or 1000 ohm RTDs with alpha
of 0.00385 or 0.00392. Input and output configuration is via RS-485 using
the DRX-CONFIG software package. The DRX series features 3-way isolation
to 1800V peak, ±1°C accuracy and resolution to 0.1°C. |
|
Model
No.
|
AC
VOLTAGE INPUT |
|
DRX-ACV
|
DRX-ACV
The DRX-ACV signal conditioner accepts AC voltage input ranges of 400mV,
4V, 40V and 400V. Accuracy is 0.2% with 13 bit resolution and computer
scalable via RS-485 using the DRX-CONFIG software package. The DRX series
features 3-way isolation to 1800V peak. |
|
Model
No.
|
AC
CURRENT INPUT |
|
DRX-ACC
|
DRX-ACC
The DRX-ACC signal conditioner accepts AC current input ranges of 10, 100mA,
1A or 5A. Accuracy is 0.2% with 13 bit resolution and computer scalable
via RS-485 using the DRX-CONFIG software package. The “DRX series features
3-way isolation to 1800V peak. |
|
Model
No.
|
FREQUENCY/PULSE
INPUT |
|
DRX-FP
|
DRX-FP
The DRX-FP signal conditioner accepts pulse inputs from NPN/PNP open collector,
TTL/CMOS, magnetic and NAMUR proximity sensor outputs. Excitation of 5,
8.2 or 12.5Vdc @ 25mA is available for the transducer. Frequency (0.2-50kHz)
or Totalize/Reset is standard. The Reset input can be reconfigured as a
second input to support A-B or Quadrature Totalize modes. |
| ACCESSORIES |
|
DB9-RJ12
|
DB9
TO RJ12 Connector Adaptor includes 7 ft |
|
DB25-RJ12
|
DB25
to RJ12 Connector Adaptor RJ12 Cord |
|
CAT-285
|
Bi-directional
RS-232/RS-485 converter for DRX |
|
DRN-PS-1000
|
Switching
Power supply, 95-240 Vac input, 24 Vdc output @850mA |
INFINITY®
SIGNAL CONDITIONERS
RS-232
CONFIGURABLE WITH ANALOG OUTPUT
|
Model
No.
|
PROCESS
VOLTAGE OR CURRENT DRX-PR |
|
DRN-PR
|
The
DRN-PR-C signal conditioner accepts process signal inputs within the spans
of 400mV, 1, 2, 5, 10V, and 20mA. Excitation of 10 or 14Vdc @ 20mA max.
is available for use with the input device. Accuracy is 0.1% with 13 bit
resolution and computer scalable via RS-232 using the DRN-CONFIG software
package. |
|
Model
No.
|
STRAIN
GAGE/BRIDGE OR MILLIVOLT |
|
DRN-ST
|
The
DRN-ST-C signal conditioner accepts strain gage/bridge or millivolt inputs
with ratiometric or absolute measurement. 10V excitation is standard. Input
spans of 30 or 100mV full scale. Accuracy is 0.1% with 13 bit resolution
and computer scalable via RS-232 using the DRN-CONFIG software package. |
|
Model
No.
|
THERMOCOUPLE
INPUT |
|
DRN-TC
|
DRX-TC
The DRX-TC signal conditioner accepts thermocouple types J, K, T, R, S,
B, N and J-DIN. The analog output is configurable for 0 to 10Vdc, 0 to
20mA or 4 to 20mA. Input and output configuration is via RS-485 using the
DRN-CONFIG software package. The DRX series features 3-way isolation to
1800V peak, ±1°C accuracy and resolution to 0.3°C above
-200°C. |
|
Model
No.
|
RTD
INPUT |
|
DRN-RTD
|
The
DRN-RTD-C signal conditioner accepts 100, 500 or 1000 ohm RTDs with alpha
of 0.00385 or 0.00392. Input and output configuration is via RS-232 using
the DRN-CONFIG software package. The DRN series features 3-way isolation
to 1800V peak, ±1°C accuracy and resolution to 0.1°C. |
|
Model
No.
|
AC
VOLTAGE INPUT |
|
DRN-ACV
|
The
DRN-ACV-C signal conditioner accepts AC voltage input ranges of 400mV,
4V, 40V and 400V. Accuracy is 0.2% with 13 bit resolution and computer
scalable via RS-232 using the DRN-CONFIG software package. The DRN series
features 3-way isolation to 1800V peak. |
|
Model
No.
|
AC
CURRENT INPUT |
|
DRN-ACC
|
The
DRN-ACC-C signal conditioner accepts AC current input ranges of 10, 100mA,
1A or 5A. Accuracy is 0.2% with 13 bit resolution and computer scalable
via RS-232 using the DRN-CONFIG software package. The DRN series features
3-way isolation to 1800V peak. |
|
Model
No.
|
FREQUENCY/PULSE
INPUT |
|
DRN-FP
|
DRX-FP
The DRX-FP signal conditioner accepts pulse inputs from NPN/PNP open collector,
TTL/CMOS, magnetic and NAMUR proximity sensor outputs. Excitation of 5,
8.2 or 12.5Vdc @ 25mA is available for the transducer. Frequency (0.2-50kHz)
or Totalize/Reset is standard. The Reset input can be reconfigured as a
second input to support A-B or Quadrature Totalize modes. |
| ACCESSORIES |
|
DB9-RJ12
|
DB9
TO RJ12 Connector Adaptor includes 7 ft |
|
DB25-RJ12
|
DB25
to RJ12 Connector Adaptor RJ12 Cord |
|
CAT-285
|
Bi-directional
RS-232/RS-485 converter for DRX |
|
DRN-PS-1000
|
Switching
Power supply, 95-240 Vac input, 24 Vdc output @850mA |
|
|