Newport Process Input Panel Meters, Controllers, and Transmitters
i-Series 1/8 DIN Meters and PID Controllers
i-Series 1/8 DIN Meters and Controllers - Compact
Case
i-Series 1/8 DIN Dual Display Vertical PID
Contollers
i-Series 1/8 DIN Dual Display Horizontal
PID Controllers
i-Series 1/16 DIN Single and Dual Display Meters
and PID Controllers
i-Series 1/32 DIN Meters and PID Controllers
Remote Display for i-Series Products
Infinity Series 1/8 DIN Panel Meters
Infinity C Series 1/8 DIN Process Meter
/ Controller
IDP 1/8 DIN Process Panel Meter
Micro Infinity 1/16 DIN Process PID
Controller
Model 205 3/64 DIN Process Meter
Model 202A 3.5 digit Panel Meter
Model 2002B 4.5 digit Panel Meter
5XX Series Display / transmitters
- i8 Series ---
1/8 DIN Temperature & Process Meters & PID
Controllers
Specifications:
-
Extended 5-year Warranty
-
High Accuracy ±0.5°C (0.9°F), 0.03% Reading
-
Full Autotune PID Control (Optional)
-
User Friendly, Simple to Configure
-
Embedded Ethernet
-
Free Software, Active X Controls
-
Largest Display (21mm LED’s) of Any 1/8 DIN Instrument
-
Universal Inputs: Thermocouple, RTD, Process Voltage/Current
-
Totally Programmable Color Displays
-
Built-in Excitation, 24 Vdc, Standard
-
2 Control or Alarm Outputs (Optional)
-
dc Pulse
-
Mechanical Relays
-
Analog Voltage and Current
-
±0.04°C /°C RTD and ±0.05°C /°C TC
@ 25°C (77°F)
-
NEMA-4, IP65 Front Bezel
-
Front Removable and Plug Connectors
|
- 1/8 DIN
Ordering Info
|
-i8C Series (Compact Case) ---
-
Compact 1/8 DIN Meter and Controller
-
Big Display with Color Changing Feature
-
Built-in Excitation
-
NEMA 4 (iP65) Bezel
-
RS-232, RS 422/485 or Modbus Communication, Menu Selectable
|
 |
ORDERING INFORMATION:
i800 Monitor
only (no control outputs) 1/8 DIN
i8C00 Monitor only (no control
outputs) 1/8 DIN Compact Case *2
i8A00 Monitor with Isolated
Analog Output 1/8 DIN
CONTROL OUTPUTS #1 & #2 Direct (Cool) or
Reverse (Heat) Acting
i8 (*) (*)
Two control outputs 1/8 DIN
i8C (*) (*)
Two control outputs 1/8 DIN Compact Case
i8A (*) (*)
Isolated Analog Output with one control and one alarm output
| (*) |
(*) |
|
| 2 |
2 |
Two solid state relays (SSR's): 0.5 A @ 120/240
Vac continuous |
| 2 |
3 |
SSR and relay: Form “C” SPDT 3 A @ 120 Vac, 3
A @ 240 Vac |
| 2 |
4 |
SSR and pulsed 10 Vdc @ 20 mA (for use with external
SSR) |
| 3 |
3 |
2 Relays: Form “C” SPDT 3 A @ 120 Vac, 3 A @
240 Vac |
| 4 |
2 |
Pulsed 10 Vdc @ 20 mA (for use with external
SSR) and SSR |
| 4 |
3 |
Pulsed 10 Vdc @ 20 mA (for use with external
SSR) and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac |
| 4 |
4 |
Two pulsed 10 Vdc @ 20 mA (for use with external
SSR) |
| 5 |
2 |
Analog Output selectable as either control or
retransmission of process value; 0 to 10 Vdc or 0-20 mA @ 500 ohm max.
and SSR |
| 5 |
3 |
Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm
max. and Relay |
| 5 |
4 |
Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm
max. and Pulse 10 Vdc |
NETWORK
OPTIONS:
| -EI |
Ethernet with Embedded Web Server |
| -C24 |
Isolated RS-232 and RS-485/422. 300 to 19.2k
Baud *3 |
| -C4EI |
Ethernet with Embedded Web Server + Isolated
RS-485/422 hub for up to 31 devices *3 |
POWER SUPPLY :
| * |
Standard power input: 90 to 240 Vac/dc, 50 to
400 Hz (no entry required) |
| -DC |
12-36 Vdc, 24 Vac *3 |
FACTORY SETUP :
| -FS |
Factory Setup and Configuration (requires -C24
Serial Communication option) |
ORDERING EXAMPLE :
i8A00 is a 1/8 DIN Meter with isolated
scalable analog retransmission of the process value
*1
Analog Output (Option 5) and Ethernet Options are not available for the
i8A controller.
*2
Isolated Analog Output and Ethernet options are not available in the compact
case.
*3
-DC, -C24, or -C4EI not available with excitation.
-i8DV and i8DH ---
Dual Display Vertical and Dual Display Horizontal
1/8 DIN Temperature & Process Meters & PID
Controllers
Specifications:
-
Extended 5-year Warranty
-
High Accuracy ±0.5°C (0.9°F), 0.03% Reading
-
Full Autotune PID Control (Optional)
-
User Friendly, Simple to Configure
-
Embedded Ethernet
-
Free Software, Active X Controls
-
Largest Display (21mm LED’s) of Any 1/8 DIN Instrument
-
Universal Inputs: Thermocouple, RTD, Process Voltage/Current
-
Totally Programmable Color Displays
-
Built-in Excitation, 24 Vdc, Standard
-
2 Control or Alarm Outputs (Optional)
-
dc Pulse
-
Mechanical Relays
-
Analog Voltage and Current
-
±0.04°C /°C RTD and ±0.05°C /°C TC
@ 25°C (77°F)
-
NEMA-4, IP65 Front Bezel
-
Front Removable and Plug Connectors
|
i8DH
i8DV
|
ORDERING INFORMATION :
CONTROL OUTPUTS #1 & #2 Direct (Cool) or
Reverse (Heat) Acting :
i8DH (*)
(*) Two Control Outputs only 1/8 DIN Dual
Display Horizontal
i8DV (*)
(*) Two Control Outputs only 1/8 DIN Dual
Display Vertical
| (*) |
(*) |
|
| 2 |
2 |
Two solid state relays (SSR's): 0.5 A @ 120/240
Vac continuous |
| 2 |
3 |
SSR and relay: Form “C” SPDT 3 A @ 120 Vac, 3
A @ 240 Vac |
| 2 |
4 |
SSR and pulsed 10 Vdc @ 20 mA (for use with external
SSR) |
| 3 |
3 |
2 Relays: Form “C” SPDT 3 A @ 120 Vac, 3 A @
240 Vac |
| 4 |
2 |
Pulsed 10 Vdc @ 20 mA (for use with external
SSR) and SSR |
| 4 |
3 |
Pulsed 10 Vdc @ 20 mA (for use with external
SSR) and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac |
| 4 |
4 |
Two pulsed 10 Vdc @ 20 mA (for use with external
SSR) |
| 5 |
2 |
Analog Output selectable as either control or
retransmission of process value; 0 to 10 Vdc or 0-20 mA @ 500 ohm max.
and SSR |
| 5 |
3 |
Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm
max. and Relay |
| 5 |
4 |
Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm
max. and Pulse 10 Vdc |
NETWORK
OPTIONS :
| -EI |
Ethernet with Embedded Web Server |
| -C24 |
Isolated RS-232 and RS-485/422. 300 to 19.2k
Baud *3 |
| -C4EI |
Ethernet with Embedded Web Server + Isolated
RS-485/422 hub for up to 31 devices *3 |
POWER SUPPLY :
| * |
Standard power input: 90 to 240 Vac/dc, 50 to
400 Hz (no entry required) |
| -DC |
12-36 Vdc, 24 Vac *3 |
FACTORY SETUP :
| -FS |
Factory Setup and Configuration (requires -C24
Serial Communication option) |
ORDERING EXAMPLE :
i8A22 is a 1/8 DIN Controller with Isolated
scalable analog retransmission of the process value with two SSR
.
*1
Analog Output (Option 5) and Ethernet Options are not available for the
i8A controller.
*2
Isolated Analog Output and Ethernet options are not available in the compact
case.
*3
-DC, -C24, or -C4EI not available with excitation.
-i16 Series ---
1/16 DIN Temperature & Process Meters & PID
Controllers
Specifications:
-
5-year Warranty
-
High Accuracy ±0.5°C (0.9°F), 0.03% Reading
-
Full Autotune PID Control
-
User Friendly, Simple to Configure
-
Free Software, Active X Controls
-
Emedded Ethernet Connectivity
-
Universal Inputs: Thermocouple, RTD, Process Voltage/Current
-
First 1/16 DIN Controller with Totally Programmable Color Displays
(Standard)
-
First 1/16 DIN Controller with Built-in Excitation, 24 Vdc, Standard
-
First 1/16 DIN Instrument Offering Both RS-232 and RS-485 Serial
Communications in One Instrument (Optional)
-
First 1/16 DIN Instrument with Analog Output Selectable as a Control
Output or as a Calibrated Retransmission of Process Variable
-
2 Control or Alarm Outputs (Optional)
-
DC Pulse
-
Solid State Relays (SSR's)
-
Mechanical Relays
-
Analog Voltage and Current
-
±0.04°C /°C RTD and ±0.05°C /°C TC
@ 25°C (77°F)
-
NEMA-4, IP65 Front Bezel
-
Front Removable and Plug Connectors
|
- 1/16 DIN
i16
i16D
Ordering Info
|
ORDERING INFORMATION :
i1600 Monitor only (no control
outputs) 1/16 DIN
CONTROL OUTPUTS #1 & #2 Direct (Cool) or
Reverse (Heat) Acting :
i16 (*)
(*) Two control outputs 1/16 DIN
i16D (*)
(*) Two control outputs with dual display
1/16 DIN *1
| (*) |
(*) |
|
| 2 |
2 |
Two solid state relays (SSR's): 0.5 A @ 120/240
Vac continuous |
| 2 |
3 |
SSR and relay: Form “C” SPDT 3 A @ 120 Vac, 3
A @ 240 Vac |
| 2 |
4 |
SSR and pulsed 10 Vdc @ 20 mA (for use with external
SSR) |
| 3 |
3 |
2 Relays: Form “C” SPDT 3 A @ 120 Vac, 3 A @
240 Vac |
| 4 |
2 |
Pulsed 10 Vdc @ 20 mA (for use with external
SSR) and SSR |
| 4 |
3 |
Pulsed 10 Vdc @ 20 mA (for use with external
SSR) and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac |
| 4 |
4 |
Two pulsed 10 Vdc @ 20 mA (for use with external
SSR) |
| 5 |
2 |
Analog Output selectable as either control or
retransmission of process value; 0 to 10 Vdc or 0-20 mA @ 500 ohm max.
and SSR |
| 5 |
3 |
Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm
max. and Relay |
| 5 |
4 |
Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm
max. and Pulse 10 Vdc |
NETWORK
OPTIONS :
| -EI |
Ethernet with Embedded Web Server |
| -C24 |
Isolated RS-232 and RS-485/422. 300 to 19.2k
Baud *2 |
| -C4EI |
Ethernet with Embedded Web Server + Isolated
RS-485/422 hub for up to 31 devices *2 |
POWER SUPPLY :
| * |
Standard power input: 90 to 240 Vac/dc, 50 to
400 Hz (no entry required) |
| -DC |
12-36 Vdc, 24 Vac *2 |
FACTORY SETUP :
| -FS |
Factory Setup and Configuration (requires -C24
Serial Communication option) |
ORDERING EXAMPLE :
i16D44 is a 1/16 DIN dual display PID Controller
with two pulse control outputs
*1
Ethernet options are available for the i16D Controller only.
*2
-DC, -C24 or -C4EI not available with excitation.
-i32 Series ---
1/32 DIN Temperature & Process Meters & PID
Controllers
- 1/32 DIN
i32
Ordering Info
|
Specifications:
-
5-year Warranty
-
High Accuracy ±0.5°C (0.9°F), 0.03% Reading
-
Full Autotune PID Control
-
User Friendly, Simple to Configure
-
Free Software, Active X Controls
-
Universal Inputs: Thermocouple, RTD, Process Voltage/Current
-
First 1/32 DIN Instrument with Totally Programmable Color Displays
(Standard)
-
First 1/32 DIN Instrument Offering Both RS-232 and RS-485 Serial
Communications in One Instrument (Optional)
-
First 1/32 DIN Instrument with Analog Output Selectable as a Control
Output or as Retransmission of Process Variable
-
First 1/32 DIN Instrument with Built-in Excitation, 24 Vdc, Standard
-
2 Control or Alarm Outputs (Optional)
-
dc Pulse
-
Solid State Relays (SSR's)
-
Mechanical Relays
-
Analog Voltage and Current
-
±0.04°C /°C RTD and ±0.05°C /°C TC
@ 25°C (77°F)
-
NEMA-4, IP65 Front Bezel
-
Front Removable and Plug Connectors
|
ORDERING INFORMATION :
i3200 Monitor only (no control
outputs) 1/32 DIN
CONTROL OUTPUTS #1 & #2 Direct (Cool) or
Reverse (Heat) Acting :
i32 (*) (*)Two
control outputs 1/32 DIN
| (*) |
(*) |
|
| 2 |
2 |
Two solid state relays (SSR's): 0.5 A @ 120/240
Vac continuous |
| 2 |
3 |
SSR and relay: Form “C” SPDT 3 A @ 120 Vac, 3
A @ 240 Vac |
| 2 |
4 |
SSR and pulsed 10 Vdc @ 20 mA (for use with external
SSR) |
| 3 |
3 |
2 Relays: Form “C” SPDT 3 A @ 120 Vac, 3 A @
240 Vac |
| 4 |
2 |
Pulsed 10 Vdc @ 20 mA (for use with external
SSR) and SSR |
| 4 |
3 |
Pulsed 10 Vdc @ 20 mA (for use with external
SSR) and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac |
| 4 |
4 |
Two pulsed 10 Vdc @ 20 mA (for use with external
SSR) |
| 5 |
2 |
Analog Output selectable as either control or
retransmission of process value; 0 to 10 Vdc or 0-20 mA @ 500 ohm max.
and SSR |
| 5 |
3 |
Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm
max. and Relay |
| 5 |
4 |
Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm
max. and Pulse 10 Vdc |
NETWORK
OPTIONS :
| -C24 |
Isolated RS-232 and RS-485/422. 300 to 19.2k
Baud *1 |
| -EIS |
Ethernet-Serial; Bridge/Hub |
POWER SUPPLY :
| * |
Standard power input: 90 to 240 Vac/dc, 50 to
400 Hz (no entry required) |
| -DC |
12-36 Vdc, 24 Vac *1 |
FACTORY SETUP :
| -FS |
Factory Setup and Configuration (requires -C24
Serial Communication option) |
ORDERING EXAMPLE :
i3222-C24 is a 1/32 DIN PID Controller
with two solid state relays for PID control and serial communications,
both RS-232 and RS-485
*1
-DC or -C24 not available with excitation.
-Remote Display/Programmer ---
Compatible with all i-Series Meters and Controllers
Specifications:
-
1/8 DIN Panel Cutout or Surface Mount
-
Big LED’s 21 mm (.83")
-
Alarm Indicators, and Color change
-
Serial Input ASCII RS-232, RS-485 Menu selectable
-
NEMA-4 (IP65) 1/8 DIN Bezel
-
20 mm (0.80") Behind Panel and only 39 mm (1.6") over all
|
RD4
|
ORDERING INFORMATION :
RD4 - 4-Digit Remote Display for iSeries
Monitors and Controllers
OPTIONS :
CT485-Adap-110, 110 Volt Power
Supply
CT485-Adap-220, 220 Volt Power
Supply
INFU
Series ---
UNIVERSAL PANEL METER
Specifications
-
6 Digits
-
NEMA-4 (IP65) Front Bezel
-
Four Isolated Open Collector Outputs
-
Smart Filtering Detects the Difference Between
a Spike or Process Change (Patent Applied For)
-
Peak and Valley Detection and Memory
-
Digital Tare
-
1.5 to 11 or 24 Vdc Sensor Excitation
Options
-
Isolated Dual 7 Amp Form C Relays
-
Isolated Parallel BCD Output
-
Isolated Analog Output 0-10 Vdc, 0-5 Vdc, 1-5
Vdc, 0-20 mA dc and 4-20 mA dc
-
Isolated Serial RS-232
-
Isolated RS-485, Addressable up to 199 Units
|

Ordering Info
|
INFP
Series Process Meter ---
SPECIFICATIONS
-
6 Digit Display
-
Split Meter with Remote Display
-
Four Isolated Open Collector Outputs
-
Wide Selection of dc Voltage and Current Ranges
-
High Accuracy of ±0.005% of Reading
-
Large Digital Offset Capabilities Enabling Easy Scaling in Engineering
Units
-
Smart Filtering Detects the Difference Between a Spike or Process
Change (Patent Applied For)
-
Selectable Decimal Point and Read Rates of up to 13 Readings/Sec
-
Peak and Valley Detection and Memory
-
Configurable Via Front Pushbuttons or Via RS-232 or RS-485
OPTIONS
-
Isolated Dual 7 Amp Form C Relays
-
Isolated Parallel BCD Output
-
Isolated Analog Output of 0-10 Vdc, 0-5 Vdc, 1-5 Vdc, 0-20 mA dc
and 4-20 mA dc
-
Isolated Serial RS-232
-
Isolated RS-485, Addressable up to 199 Units
|
Six full digits and broad scaling capabilities make the INFP meter
ideal for demanding process control applications. Suited for even the most
hostile environments with a gasketed front bezel, this meter offers on-board
excitation to let you power virtually any sensor or transmitter.
Ordering Info
|
INFCP-B INFINITY®
C Process Meter / Controller ---
|
-
4-digit three color (Red, Green,
Amber)
Programmable LED display
-
Scaling in Wide Range of Engineering Units
-
Built-In Excitation
-
Analog Output Optional
-
Dual Relays Optional
-
Tare Button
-
Peak Memory
Ordering Info
|
INFCP-(*)00 B Digital Process Meter with excitation,
basic unit
INFCP-(*)01 B Digital Process Meter with
non-isolated analog output
INFCP-(*)10 B Digital Process Meter with
dual setpoint (5-Amp form "C" relays )
INFCP-(*)11 B Digital Process Meter with
non-isolated analog output
INFCP-(*)12 B Digital Process Meter with
setpoint and isolated Analog output
Power and Display Selection
| Order Code |
Power |
Display |
| 0 |
115 Vac |
Red |
| 1 |
230 Vac |
Red |
| 2 |
115 Vac |
Green |
| 3 |
230 Vac |
Creen |
| 4 |
10-32 Vdc |
Red |
| 5 |
10-32 Vdc |
Green |
| 6 |
26-56 Vdc |
Red |
| 7 |
26-56 Vdc |
Green |
Ordering Example:
INFCP-010B, process meter with dual relays,
red LED display, 115 Vac power
IDP PANEL MOUNT PROCESS METER
---
|
-
Very easy scaling
-
Easily Scaled in Any Engineering Unit from
-1999 to 9999
-
Full-Size 0.56" (14.2 mm) LED Display
-
Contains 24 Vdc or 10 Vdc for Transducer Excitation
-
Front Panel Min or Max and Tare Functions
-
External Display Hold and Tare Standard
-
Exceeds High Standards for Immunity and Emission
Ordering Info
|
To Order:
| Model # |
Power |
Display |
| IDP-0 |
115 Vac |
Red LED, 4-digit |
| IDP-1 |
230 Vac |
Red LED, 4-digit |
| IDP-2 |
115 Vac |
Green LED, 4-digit |
| IDP-3 |
230 Vac |
Green LED, 4-digit |
| IDP-4 |
10-32 Vdc |
Red LED, 4-digit |
| IDP-5 |
10-32 Vdc |
Green LED, 4-digit |
Includes operator’s manual.
ACCESSORIES:
| Suffix |
Description |
| -G |
Green LED display |
| -230 |
230 Vac power |
| -DC |
9-32 Vdc Isolated power |
| -SPC4 |
NEMA-4 splash-proof lens with screw clamp |
| -SPC18 |
NEMA-4 splash-proof lens with spring clip |
| -BBZL |
Removable buttonless bezel |
Ordering Example:
MODEL IDP-0-SPC4 meter with 115 Vac power
and red LED display, with SPC4 optional NEMA-4 lens cover and CE rating
Micro-Infinity™ Series
1/16 DIN ---
-
Autotune Temp./Process Controllers
-
NEMA 4 and NEMA 12 Models
-
Single and Dual Output Models Available
-
Dual 4-Digit LED Display with Indicators for Output and Alarm Status
-
Relay, SSR, DC Pulse, 0 to 10 V and 0 to 20mA Output Types
-
Ramp to Setpoint Feature Standard
-
Universal Power Supply, AC or DC
-
Thermocouple, RTD or Process Voltage/Current Input
-
Dual Output and Dual Alarm Capability
-
Optional RS-232, RS-485, Analog Output or Remote Setpoint Selection
-
Accuracy: ±0.5°C, 0.03% rdg, process
-
Resolution: 1°/0.1°, 10 µV process
-
Temperature Stability: 0.08°C/°C; 50 ppm/°C process
-
Power: 90 to 250V AC/DC, 50 to 400 Hz; 10 to 34V AC/DC power optional
MODEL
ICN77000
|
Model
No.
|
PROCESS
CONTROLLER, DUAL DISPLAY FOR THERMOCOUPLE, RTD, VOLTAGE OR CURRENT INPUTS
IN A 1 /16 DIN CASE |
|
ICN77
|
Dual
displays for display of measured value and setpoint. Selectable preset
tune, adaptive tune, auto-tune, PID, PI, PD. The control outputs are independently
configurable for direct or reverse acting PID or ON/OFF operation. The
ramp to setpoint feature defines the rate of rise to setpoint, minimizing
thermal shock to the load during start-up. Max ramp and or Soak to 99.59
(HH.MM), Damping: 1 to 8 in unit steps. Input types include J, K, T, E,
R, S, B, N, DIN-J, RTD 100ohm with alpha of 0.00385 or 0.00392 0-20mA,
0- 100mV, 0-1V, and 0-10Vdc. Standard Alarm 1 output includes SPST relay,
5A @ 120Vac, 3A @ 240Vac. |
|
OPTIONS
|
DESCRIPTION |
| ROUND
CUTOUT (1 3/4" DIA.) |
|
*
|
Omit
for standard square 1/16 DIN cutout |
|
R
|
Round
cutout with detachable NEMA 1 faceplate for fast, easy installation. Cutout
diameter is 1.75" (44 mm) |
| PACKAGE
CONFIGURATION |
|
3
|
INFINITY®
style NEMA 12 1/16 DIN bezel 1.89 sq. and standard 1/16 DIN 1.772" (45mm)
sq. panel cutout |
| CONTROL
OUTPUT 1 |
|
2
|
2
Solid state relay SSR: 1A @ 120/240 Vac continuous |
|
3
|
Relay:
form “C” 5A @ 120Vac, 3A @ 240Vac |
|
4
|
Pulsed
10Vdc @ 20mA (use for external SSR) |
|
5
|
Non-isolated
1 to 10Vdc or 0 to 20mA @500 ohm max |
| CONTROL
OUTPUT 2 |
|
0
|
Enter
“0” if second output is not needed |
|
2
|
Solid
state relay SSR: 1A @ 120/240 Vac continuous |
|
3
|
Relay:
5A @ 120Vac, 3A @ 240Vac |
|
4
|
4
Pulsed 10Vdc @ 20mA (use for external SSR) |
| OPTIONAL
OUTPUT |
|
*
|
None |
|
-A2
|
Second
Alarm, SPST relay, 5A @ 120 Vac, 3A @ 240Vac |
|
-C2
|
Isolated
RS 232, 300 to 19.2k baud |
|
-C4
|
Isolated
RS 485, 300 to 19.2k baud |
|
-PV
|
Isolated
Analog Output (scaled from process variable) |
|
-RSP
|
Remote
Setpoint selection |
| POWER
SUPPLY |
|
*
|
90
to 250 Vac/dc, 50 to 400 Hz (Standard) |
| ADD-ON
OPTIONS |
|
RHS43
|
Arbored
holesaw 43mm (1 11/16") for ICN77R meters |
|
TP4
|
Trimplate
adapter to install 1/16 DIN meter in existing 1/4 DIN panel cutout |
|
TP6
|
Trimplate
adapter to install 1/16 DIN meter in existing 1/8 DIN panel cutout |
Ordering
Example: ICN77R323,C2
$279:
Round panel cutout with relay as second control output, RS-232 communication
and solid state relay (SSR) as control output 1.
Note: The
controller must be ordered completely configured. Options are not field
installable. |
Model 205 Miniature 3/64 DIN Panel
Meter with Full Size Display ---
STANDARD FEATURES
-
Zero and Span Adjustments of 2,000 Counts Each
-
±1,999 -Count Display Span
-
120 dB CMR, 56 dB NMR
-
Bright, 14.2 mm (0.56") LED Display
-
EMI/RFI Filter for ac Power
-
Removable Screw-Clamp Connector
-
Miniature DIN Case with 24 x 72 mm (0.94" x 2.83") Bezel
OPTIONS
-
Isolated Transmitter Excitation Supply
-
4-20 mA, 1-5 V, 0-10 V Signal Ranges
-
Red or Green LED Display
-
24, 100, 115 or 230 Vac Power
-
25 x 75 mm (0.98 x 2.96") Bezel Adapter
-
NEMA-4 Splash-Proof Lens Cover
|
Ordering Info
|
To
Order :
|
Model
Number
|
Description
|
|
205
|
( * )
|
3/64
DIN case |
|
305
|
( * )
|
1/8
DIN case with INFINITY bezel |
|
Input
|
Range
Code
|
Range°F
|
Range°C
|
Resolution
|
Iron-Constantan
|
JC1-R,
C0
JC2-R, C0
JF1-R, C0
JF2-R, C0
|
-346 to
1400°F
-199.9 to 199.9°F
|
-210 to
760°C
-199.9 to 199.9°C
|
1°C
/ 0.1°C
1°F / 0.1°F
|
Chromel-Alumel
|
KC1-R,
C0
KC2-R, C0
KF1-R, C0
KF2-R, C0
|
-157 to
1999°F
-199.9 to 199.9°F
|
-105 to
1372°C
-199.9 to 199.9°C
|
1°C
/ 0.1°C
1°F / 0.1°F
|
Copper-Constantan
|
TC1-R,
C0
TC2-R, C0
TF1-R, C0
TF2-R, C0
|
-157 to
752°F
-199.9 to 199.9°F
|
-105 to
400°C
-199.9 to 199.9°C
|
1°C
/ 0.1°C
1°F / 0.1°F
|
Chromel-Constantan
|
EC1-R,
C0
EC2-R, C0
EF1-R, C0
EF2-R, C0
|
-157 to
1832°F
-199.9 to 199.9°F
|
-105 to
1000°C
-199.9 to 199.9°C
|
1°C
/ 0.1°C
1°F / 0.1°F
|
100 ohm Pt
|
MC1-R,
C0
MC2-R, C0
MF1-R, C0
MF2-R, C0
|
-328 to
1562°F
-199.9 to 199.9°F
|
-200 to
850°C
-199.9 to 199.9°C
|
1°C
/ 0.1°C
1°F / 0.1°F
|
To order with
green display, change R to G in model number, no additional cost.
Power
Options: for
non-isolated 9-26 Vdc, change C0 to C2A in model number, no additional
cost.
Ordering
Example: 305-KC1-R-C0,
type K meter, with -105 to 1372°C range, 1° resolution
202A/2002B Process, Strain,
Temperature & Resistance Indicators/Controllers ---
-
Full-Size 0.56" (14.2mm) red or green LED Display
-
Field-scalability for process or strain inputs
-
Linearization of thermocouple or RTD inputs
-
Display hold and test
-
Auto polarity
-
EMI/RMI filter for AC power
-
Screw-terminal barrier strip for power and signal
-
Short 1/8 DIN case
-
202A: ±1,999 count display span (3-1/2 digit)
-
2002B: ±19,999 count display span (41/2 digit)
MOST POPULAR MODELS :
202A-P DC volt or mA process
receiver
202A-E DC volt or mA process
receiver with sensor excitation
202A-S Strain gage indicator
w/sensor excitation
202A-JF1 Type J T/C indicator,
1° resolution
202A-KF1 Type K T/C indicator,
1° resolution
2002B-P DC volt or mA
process receiver
2002B-KF1 Type K T/C
indicator, 1° resolution
500 Series Two-Wire, Loop-Powered
Process Indicators
Model 508B ---
|
STANDARD FEATURES :
-
FM, CSA, BASEEFA Intrinsic Safety Certification
-
Powered by 1-5, 4-20 or 10-50 mA Signal
-
2.5 V Max Voltage Drop
-
0.35 in (8.9 mm) Liquid Crystal Display
-
2,000-Count Zero Suppression or Elevation
-
100 to 2,000 Count Span Adjust
-
Selectable Dummy Right-Hand Zero
-
–40°C to +85°C Operation
-
Compact, 2.9 in Diameter Die-Cast Housing
-
Waterproof to 35 kPa (5 psi)
-
Shock Resistant to 55 g
OPTIONS
-
CENELEC Intrinsic Safety Certification, FM, CSA
-
1/2 EMT Conduit Fitting
-
1/2 NPT Pipe Fitting
-
Relay-Track Mounting Adapters
-
External Explosion-Proof Housing
-
Companion Current Transmitters
|
Model 509 ---
-
Integral square-root extraction
-
NEMA 4 die-cast metal housing, weatherproof to 5 PSI
-
Temperature range -40 to +85°C
MODELS
508B / 509
|
Model
No.
|
TWO-WIRE,
FM APPROVED, PROCESS LOOP INDICATOR IN NEMA-4 HOUSING |
|
508B
|
Two-wire
current-loop indicator that accepts 4-20 mA or 10-50 mA process signals
and displays variables in percent or engineering units. Power is obtained
from current loop. Standard features include -2000 to +2000 zero adjust,
3 1/2 digit (±1999) liquid-crystal display plus selectable dummy
right-hand zero (±19990), -40 to +85°C operating temperature,
and waterproof die-cast metal housing. |
|
509
|
Same
as above except computes square root of the input and displays the process
variable in either percent or in engineering units. |
|
OPTIONS
|
DESCRIPTION |
| MECHANICAL
CONFIGURATION |
|
-1
|
For
mounting to flat surface or relay track. Connection via screw-terminal
barrier strip (TB) |
|
-2
|
For
mounting to EMT conduit. Connection via two 0.3 meter long #18 wires; 1/2-inch
EMT male pipe fitting |
|
-3
|
For
mounting to NPT pipe. Connection via two 0.3 meter long #18 wires; 1/2-inch
NPT male pipe fitting |
| MOUNTING
CONFIGURATION |
|
*
|
Case
alone for surface mount, for 63.5 mm (2.50 in) relay track or for use with
MXS1 and explosion-proof housings |
|
MAT1
|
Adapter
plate for surface mount or 69.9 mm (2.75 in) relay track |
|
MDT1
|
Rail
clamp for DIN relay track |
| CONFIGURATION
AND CALIBRATION |
|
*
|
Standard
setup (readout from 000.0 to 100.0 for 4-20 mA input) |
|
FS
|
Custom
configuration and calibration. Specify min input, min reading; max input,
max reading. Include decimal point and dummy right-hand zero (if selected) |
| SAFETY
CERTIFICATION |
|
*
|
FM
IS certification label (standard) |
|
IS1
|
CENELEC
EEx ia certification label (508-B only) |
| ACCESSORIES |
|
LB1
|
Loop
break connector adapter provides continuity when device is removed from
loop (508B-1 only) |
|
MXS1
|
Spring
retainers for 508B-1 or 509-1 in explosion-proof housing EPW1 or EPW3,
or 500 Series transmitter in explosion-proof housing EPW2 |
|
MXS2
|
Spring
retainers for 508B-1 or 509-1 in explosion-proof housing EPW2 |
|
EPW3
|
External
single height environmental enclosure with window for 508B-1 or 509-1,
rated NEMA-7 (explosion-proof) and NEMA-4 (waterproof). Certified by FM
and CENELEC. Includes internal mounting hardware MXS1 |
|
EPW2
|
External
double-height environmental enclosure with window for one 508A-1 or 509-1
and one 500 Series transmitter for indicating two-wire applications. Rated
NEMA-7 (explosion-proof) and NEMA-4 (water-proof). Includes FM and CENELEC
certification and internal mounting hardware MXS1 and MXS2 |
|
MOST
POPULAR MODEL
|
|
508B-1
|
3
1/2 digit LCD, 2-wire current loop indicator, configured to accept 4-20
mAdc input |
$325.00
|
|
Model 558B ---
|
STANDARD FEATURES :
-
Powered by 1-5 mA, 4-20 mA or 10-50 mA Signal
-
2.5 V Max Voltage Drop
-
Display to ±1,999, ±19,990 or ±199,900
-
0.5 inch (12.7 mm) Liquid-Crystal Display
-
100 to 2,000 Count Span Adjust
-
2,000-Count Zero Suppression or Elevation
-
Short 1/8 DIN Case
-
Simple 2-Wire Hook Up
-
Safe Plug-in Screw-Clamp Connector
OPTIONS:
-
Intrinsic Safety Certification
-
–40 to +85°C Operating Temperature
-
NEMA-4 Splash-Proof Lens Cover
|
MOST POPULAR MODELS :
558B
Two-wire current-loop indicator, 0 to +55° operating range
558B-ET Two-wire current-loop
indicator, -40 to +85° extended operating range
ADD-ON OPTIONS :
BL Lens
without Newport logo
FS Custom
configuration and calibration. Specify min input, min reading; max input,
max reading. Include decimal point and any dummy right-hand zeros
IS1 Intrinsic-safety
certification with CENELEC EEx ia certification label
|