Contact the closest office: 1-800-358-5525

   Newport Process Input Panel Meters, Controllers, and Transmitters

 i-Series 1/8 DIN Meters and PID Controllers
 i-Series 1/8 DIN Meters and Controllers - Compact Case
 i-Series 1/8 DIN Dual Display Vertical PID Contollers
 i-Series 1/8 DIN Dual Display Horizontal PID Controllers
 i-Series 1/16 DIN Single and Dual Display Meters and PID Controllers
 i-Series 1/32 DIN Meters and PID Controllers
 Remote Display for i-Series Products

 Infinity Series 1/8 DIN Panel Meters
 Infinity C Series 1/8 DIN Process Meter / Controller

 IDP 1/8 DIN Process Panel Meter

 Micro Infinity 1/16 DIN Process PID Controller

 Model 205 3/64 DIN Process Meter
 Model 202A 3.5 digit Panel Meter
 Model 2002B 4.5 digit Panel Meter

 5XX Series Display / transmitters


   - i8 Series ---

1/8 DIN Temperature & Process Meters & PID Controllers

Specifications:

  •  Extended 5-year Warranty 
  •  High Accuracy ±0.5°C (0.9°F), 0.03% Reading 
  •  Full Autotune PID Control (Optional) 
  •  User Friendly, Simple to Configure 
  •  Embedded Ethernet 
  •  Free Software, Active X Controls 
  •  Largest Display (21mm LED’s) of Any 1/8 DIN Instrument 
  •  Universal Inputs: Thermocouple, RTD, Process Voltage/Current 
  •  Totally Programmable Color Displays
  •  Built-in Excitation, 24 Vdc, Standard 
  •  2 Control or Alarm Outputs (Optional)
    • dc Pulse
    • Mechanical Relays
    • Analog Voltage and Current 
  •  ±0.04°C /°C RTD and ±0.05°C /°C TC @ 25°C (77°F) 
  •  NEMA-4, IP65 Front Bezel 
  •  Front Removable and Plug Connectors
- 1/8 DIN

Buy It Now ! Ordering Info

  -i8C Series (Compact Case) ---


 
  • Compact 1/8 DIN Meter and Controller
  • Big Display with Color Changing Feature 
  •  Built-in Excitation 
  •  NEMA 4 (iP65) Bezel 
  •  RS-232, RS 422/485 or Modbus Communication, Menu Selectable

ORDERING INFORMATION:

i800      Monitor only (no control outputs) 1/8 DIN
i8C00   Monitor only (no control outputs) 1/8 DIN Compact Case *2
i8A00   Monitor with Isolated Analog Output 1/8 DIN

CONTROL OUTPUTS #1 & #2 Direct (Cool) or Reverse (Heat) Acting 
i8 (*) (*)     Two control outputs 1/8 DIN
i8C (*) (*)  Two control outputs 1/8 DIN Compact Case
i8A (*) (*)   Isolated Analog Output with one control and one alarm output
 
(*) (*)
2 2 Two solid state relays (SSR's): 0.5 A @ 120/240 Vac continuous 
2 3 SSR and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac
2 4 SSR and pulsed 10 Vdc @ 20 mA (for use with external SSR) 
3 3 2 Relays: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac 
4 2 Pulsed 10 Vdc @ 20 mA (for use with external SSR) and SSR 
4 3 Pulsed 10 Vdc @ 20 mA (for use with external SSR) and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac 
4 4 Two pulsed 10 Vdc @ 20 mA (for use with external SSR) 
5 2 Analog Output selectable as either control or retransmission of process value; 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and SSR 
5 3 Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and Relay
5 4 Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and Pulse 10 Vdc

 NETWORK OPTIONS:
 
-EI Ethernet with Embedded Web Server
-C24 Isolated RS-232 and RS-485/422. 300 to 19.2k Baud *3
-C4EI Ethernet with Embedded Web Server + Isolated RS-485/422 hub for up to 31 devices *3

POWER SUPPLY :
 
* Standard power input: 90 to 240 Vac/dc, 50 to 400 Hz (no entry required)
-DC 12-36 Vdc, 24 Vac *3

FACTORY SETUP :
 
-FS Factory Setup and Configuration (requires -C24 Serial Communication option)

ORDERING EXAMPLE :

i8A00 is a 1/8 DIN Meter with isolated scalable analog retransmission of the process value

*1 Analog Output (Option 5) and Ethernet Options are not available for the i8A controller.
*2 Isolated Analog Output and Ethernet options are not available in the compact case.
*3 -DC, -C24, or -C4EI not available with excitation.


  -i8DV and i8DH ---

Dual Display Vertical and Dual Display Horizontal

1/8 DIN Temperature & Process Meters & PID Controllers

Specifications:

  •  Extended 5-year Warranty 
  •  High Accuracy ±0.5°C (0.9°F), 0.03% Reading 
  •  Full Autotune PID Control (Optional) 
  •  User Friendly, Simple to Configure 
  •  Embedded Ethernet 
  •  Free Software, Active X Controls 
  •  Largest Display (21mm LED’s) of Any 1/8 DIN Instrument 
  •  Universal Inputs: Thermocouple, RTD, Process Voltage/Current 
  •  Totally Programmable Color Displays
  •  Built-in Excitation, 24 Vdc, Standard 
  •  2 Control or Alarm Outputs (Optional)
    • dc Pulse
    • Mechanical Relays
    • Analog Voltage and Current 
  •  ±0.04°C /°C RTD and ±0.05°C /°C TC @ 25°C (77°F) 
  •  NEMA-4, IP65 Front Bezel 
  •  Front Removable and Plug Connectors
i8DH

i8DV
 

ORDERING INFORMATION :

CONTROL OUTPUTS #1 & #2 Direct (Cool) or Reverse (Heat) Acting :
i8DH (*) (*) Two Control Outputs only 1/8 DIN Dual Display Horizontal
i8DV (*) (*) Two Control Outputs only 1/8 DIN Dual Display Vertical
 
(*) (*)
2 2 Two solid state relays (SSR's): 0.5 A @ 120/240 Vac continuous 
2 3 SSR and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac
2 4 SSR and pulsed 10 Vdc @ 20 mA (for use with external SSR) 
3 3 2 Relays: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac 
4 2 Pulsed 10 Vdc @ 20 mA (for use with external SSR) and SSR 
4 3 Pulsed 10 Vdc @ 20 mA (for use with external SSR) and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac 
4 4 Two pulsed 10 Vdc @ 20 mA (for use with external SSR) 
5 2 Analog Output selectable as either control or retransmission of process value; 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and SSR 
5 3 Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and Relay
5 4 Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and Pulse 10 Vdc

 NETWORK OPTIONS :
 
-EI Ethernet with Embedded Web Server
-C24 Isolated RS-232 and RS-485/422. 300 to 19.2k Baud *3
-C4EI Ethernet with Embedded Web Server + Isolated RS-485/422 hub for up to 31 devices *3

POWER SUPPLY :
 
* Standard power input: 90 to 240 Vac/dc, 50 to 400 Hz (no entry required)
-DC 12-36 Vdc, 24 Vac *3

FACTORY SETUP :
 
-FS Factory Setup and Configuration (requires -C24 Serial Communication option)

ORDERING EXAMPLE :
i8A22 is a 1/8 DIN Controller with Isolated scalable analog retransmission of the process value with two SSR
.
*1 Analog Output (Option 5) and Ethernet Options are not available for the i8A controller.
*2 Isolated Analog Output and Ethernet options are not available in the compact case.
*3 -DC, -C24, or -C4EI not available with excitation.


  -i16 Series ---

1/16 DIN Temperature & Process Meters & PID Controllers

Specifications:

  •  5-year Warranty 
  •  High Accuracy ±0.5°C (0.9°F), 0.03% Reading 
  •  Full Autotune PID Control 
  •  User Friendly, Simple to Configure 
  •  Free Software, Active X Controls 
  •  Emedded Ethernet Connectivity 
  •  Universal Inputs: Thermocouple, RTD, Process Voltage/Current 
  •  First 1/16 DIN Controller with Totally Programmable Color Displays (Standard) 
  •  First 1/16 DIN Controller with Built-in Excitation, 24 Vdc, Standard 
  •  First 1/16 DIN Instrument Offering Both RS-232 and RS-485 Serial Communications in One Instrument (Optional) 
  •  First 1/16 DIN Instrument with Analog Output Selectable as a Control Output or as a Calibrated Retransmission of Process Variable 
  •  2 Control or Alarm Outputs (Optional)
    • DC Pulse
    • Solid State Relays (SSR's)
    • Mechanical Relays
    • Analog Voltage and Current 
  •  ±0.04°C /°C RTD and ±0.05°C /°C TC @ 25°C (77°F) 
  •  NEMA-4, IP65 Front Bezel 
  •  Front Removable and Plug Connectors
- 1/16 DIN

i16

i16D
 

Buy It Now ! Ordering Info

ORDERING INFORMATION :

i1600   Monitor only (no control outputs) 1/16 DIN

CONTROL OUTPUTS #1 & #2 Direct (Cool) or Reverse (Heat) Acting :
i16 (*) (*) Two control outputs 1/16 DIN
i16D (*) (*) Two control outputs with dual display 1/16 DIN *1
 
(*) (*)
2 2 Two solid state relays (SSR's): 0.5 A @ 120/240 Vac continuous 
2 3 SSR and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac
2 4 SSR and pulsed 10 Vdc @ 20 mA (for use with external SSR) 
3 3 2 Relays: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac 
4 2 Pulsed 10 Vdc @ 20 mA (for use with external SSR) and SSR 
4 3 Pulsed 10 Vdc @ 20 mA (for use with external SSR) and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac 
4 4 Two pulsed 10 Vdc @ 20 mA (for use with external SSR) 
5 2 Analog Output selectable as either control or retransmission of process value; 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and SSR 
5 3 Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and Relay
5 4 Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and Pulse 10 Vdc

 NETWORK OPTIONS :
 
-EI Ethernet with Embedded Web Server
-C24 Isolated RS-232 and RS-485/422. 300 to 19.2k Baud *2
-C4EI Ethernet with Embedded Web Server + Isolated RS-485/422 hub for up to 31 devices *2

POWER SUPPLY :
 
* Standard power input: 90 to 240 Vac/dc, 50 to 400 Hz (no entry required)
-DC 12-36 Vdc, 24 Vac *2

FACTORY SETUP :
 
-FS Factory Setup and Configuration (requires -C24 Serial Communication option)

ORDERING EXAMPLE :

i16D44 is a 1/16 DIN dual display PID Controller with two pulse control outputs

*1  Ethernet options are available for the i16D Controller only.
*2 -DC, -C24 or -C4EI not available with excitation.


  -i32 Series ---

1/32 DIN Temperature & Process Meters & PID Controllers

- 1/32 DIN
 
 

i32
 

Buy It Now ! Ordering Info

Specifications:

  •  5-year Warranty 
  •  High Accuracy ±0.5°C (0.9°F), 0.03% Reading 
  •  Full Autotune PID Control 
  •  User Friendly, Simple to Configure 
  •  Free Software, Active X Controls 
  •  Universal Inputs: Thermocouple, RTD, Process Voltage/Current 
  •  First 1/32 DIN Instrument with Totally Programmable Color Displays (Standard) 
  •  First 1/32 DIN Instrument Offering Both RS-232 and RS-485 Serial Communications in One Instrument (Optional) 
  •  First 1/32 DIN Instrument with Analog Output Selectable as a Control Output or as Retransmission of Process Variable 
  •  First 1/32 DIN Instrument with Built-in Excitation, 24 Vdc, Standard 
  •  2 Control or Alarm Outputs (Optional)
    • dc Pulse
    • Solid State Relays (SSR's)
    • Mechanical Relays
    • Analog Voltage and Current 
  •  ±0.04°C /°C RTD and ±0.05°C /°C TC @ 25°C (77°F) 
  •  NEMA-4, IP65 Front Bezel 
  •  Front Removable and Plug Connectors 

ORDERING INFORMATION :

i3200   Monitor only (no control outputs) 1/32 DIN

CONTROL OUTPUTS #1 & #2 Direct (Cool) or Reverse (Heat) Acting :
i32 (*) (*)Two control outputs 1/32 DIN
 
(*) (*)
2 2 Two solid state relays (SSR's): 0.5 A @ 120/240 Vac continuous 
2 3 SSR and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac
2 4 SSR and pulsed 10 Vdc @ 20 mA (for use with external SSR) 
3 3 2 Relays: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac 
4 2 Pulsed 10 Vdc @ 20 mA (for use with external SSR) and SSR 
4 3 Pulsed 10 Vdc @ 20 mA (for use with external SSR) and relay: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac 
4 4 Two pulsed 10 Vdc @ 20 mA (for use with external SSR) 
5 2 Analog Output selectable as either control or retransmission of process value; 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and SSR 
5 3 Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and Relay
5 4 Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max. and Pulse 10 Vdc

 NETWORK OPTIONS :
 
-C24 Isolated RS-232 and RS-485/422. 300 to 19.2k Baud *1
-EIS Ethernet-Serial; Bridge/Hub

POWER SUPPLY :
 
* Standard power input: 90 to 240 Vac/dc, 50 to 400 Hz (no entry required)
-DC 12-36 Vdc, 24 Vac *1

FACTORY SETUP :
 
-FS Factory Setup and Configuration (requires -C24 Serial Communication option)

ORDERING EXAMPLE :

i3222-C24 is a 1/32 DIN PID Controller with two solid state relays for PID control and serial communications, both RS-232 and RS-485

*1 -DC or -C24 not available with excitation.


  -Remote Display/Programmer  ---

Compatible with all i-Series Meters and Controllers

Specifications:

  •  1/8 DIN Panel Cutout or Surface Mount 
  •  Big LED’s 21 mm (.83") 
  •  Alarm Indicators, and Color change 
  •  Serial Input ASCII RS-232, RS-485 Menu selectable 
  •  NEMA-4 (IP65) 1/8 DIN Bezel 
  •  20 mm (0.80") Behind Panel and only 39 mm (1.6") over all 
RD4
 
 

ORDERING INFORMATION :
RD4 - 4-Digit Remote Display for iSeries Monitors and Controllers

OPTIONS : 
CT485-Adap-110,   110 Volt Power Supply
CT485-Adap-220,   220 Volt Power Supply


INFU  Series  ---

UNIVERSAL PANEL METER 

Specifications 

  •  6 Digits 
  •  NEMA-4 (IP65) Front Bezel 
  •  Four Isolated Open Collector Outputs 
  •  Smart Filtering Detects the Difference Between a Spike or Process Change (Patent Applied For) 
  •  Peak and Valley Detection and Memory 
  •  Digital Tare 
  •  1.5 to 11 or 24 Vdc Sensor Excitation 

Options 

  •  Isolated Dual 7 Amp Form C Relays 
  •  Isolated Parallel BCD Output 
  •  Isolated Analog Output 0-10 Vdc, 0-5 Vdc, 1-5 Vdc, 0-20 mA dc and 4-20 mA dc 
  •  Isolated Serial RS-232 
  •  Isolated RS-485, Addressable up to 199 Units 

Buy It Now ! Ordering Info
 


INFP  Series Process Meter  ---

SPECIFICATIONS 

  •  6 Digit Display 
  •  Split Meter with Remote Display 
  •  Four Isolated Open Collector Outputs 
  •  Wide Selection of dc Voltage and Current Ranges 
  •  High Accuracy of ±0.005% of Reading 
  •  Large Digital Offset Capabilities Enabling Easy Scaling in Engineering Units 
  •  Smart Filtering Detects the Difference Between a Spike or Process Change (Patent Applied For) 
  •  Selectable Decimal Point and Read Rates of up to 13 Readings/Sec 
  •  Peak and Valley Detection and Memory 
  •  Configurable Via Front Pushbuttons or Via RS-232 or RS-485 

OPTIONS 

  •  Isolated Dual 7 Amp Form C Relays 
  •  Isolated Parallel BCD Output 
  •  Isolated Analog Output of 0-10 Vdc, 0-5 Vdc, 1-5 Vdc, 0-20 mA dc and 4-20 mA dc 
  •  Isolated Serial RS-232 
  •  Isolated RS-485, Addressable up to 199 Units 
Six full digits and broad scaling capabilities make the INFP meter ideal for demanding process control applications. Suited for even the most hostile environments with a gasketed front bezel, this meter offers on-board excitation to let you power virtually any sensor or transmitter.
 

 

Buy It Now ! Ordering Info
 
 


INFCP-B INFINITY® C Process Meter / Controller ---


 

  • 4-digit three color (Red, Green, Amber) Programmable LED display 
  •  Scaling in Wide Range of Engineering Units 
  •  Built-In Excitation 
  •  Analog Output Optional 
  •  Dual Relays Optional 
  •  Tare Button 
  •  Peak Memory 
INFCP-(*)00 B  Digital Process Meter with excitation, basic unit
INFCP-(*)01 B  Digital Process Meter with non-isolated analog output
INFCP-(*)10 B  Digital Process Meter with dual setpoint (5-Amp form "C" relays )
INFCP-(*)11 B  Digital Process Meter with non-isolated analog output
INFCP-(*)12 B  Digital Process Meter with setpoint and isolated Analog output

Power and Display Selection 

Order Code Power   Display
0 115 Vac Red
1 230 Vac Red
2 115 Vac Green
3 230 Vac Creen
4 10-32 Vdc Red
5 10-32 Vdc Green
6 26-56 Vdc Red
7 26-56 Vdc Green

Ordering Example: 
INFCP-010B, process meter with dual relays, red LED display, 115 Vac power


IDP PANEL MOUNT PROCESS METER  ---


 

  • Very easy scaling 
  •  Easily Scaled in Any Engineering Unit from -1999 to 9999 
  •  Full-Size 0.56" (14.2 mm) LED Display 
  •  Contains 24 Vdc or 10 Vdc for Transducer Excitation 
  •  Front Panel Min or Max and Tare Functions 
  •  External Display Hold and Tare Standard 
  •  Exceeds High Standards for Immunity and Emission 

Buy It Now ! Ordering Info

To Order: 
 
Model #  Power Display
IDP-0 115 Vac Red LED, 4-digit
IDP-1 230 Vac Red LED, 4-digit
IDP-2 115 Vac Green LED, 4-digit
IDP-3 230 Vac Green LED, 4-digit
IDP-4 10-32 Vdc Red LED, 4-digit
IDP-5 10-32 Vdc Green LED, 4-digit
Includes operator’s manual.

ACCESSORIES:
 
Suffix Description
-G Green LED display
-230 230 Vac power
-DC 9-32 Vdc Isolated power
-SPC4 NEMA-4 splash-proof lens with screw clamp
-SPC18 NEMA-4 splash-proof lens with spring clip
-BBZL Removable buttonless bezel

Ordering Example:
MODEL IDP-0-SPC4 meter with 115 Vac power and red LED display, with SPC4 optional NEMA-4 lens cover and CE rating


Micro-Infinity™ Series 1/16 DIN ---


 
  • Autotune Temp./Process Controllers 
  • NEMA 4 and NEMA 12 Models 
  • Single and Dual Output Models Available 
  • Dual 4-Digit LED Display with Indicators for Output and Alarm Status 
  • Relay, SSR, DC Pulse, 0 to 10 V and 0 to 20mA Output Types 
  • Ramp to Setpoint Feature Standard 
  • Universal Power Supply, AC or DC 
  • Thermocouple, RTD or Process Voltage/Current Input 
  • Dual Output and Dual Alarm Capability 
  • Optional RS-232, RS-485, Analog Output or Remote Setpoint Selection 
  • Accuracy: ±0.5°C, 0.03% rdg, process 
  • Resolution: 1°/0.1°, 10 µV process 
  • Temperature Stability: 0.08°C/°C; 50 ppm/°C process 
  • Power: 90 to 250V AC/DC, 50 to 400 Hz; 10 to 34V AC/DC power optional 
MODEL ICN77000
Model No.
PROCESS CONTROLLER, DUAL DISPLAY FOR THERMOCOUPLE, RTD, VOLTAGE OR CURRENT INPUTS IN A 1 /16 DIN CASE
ICN77
Dual displays for display of measured value and setpoint. Selectable preset tune, adaptive tune, auto-tune, PID, PI, PD. The control outputs are independently configurable for direct or reverse acting PID or ON/OFF operation. The ramp to setpoint feature defines the rate of rise to setpoint, minimizing thermal shock to the load during start-up. Max ramp and or Soak to 99.59 (HH.MM), Damping: 1 to 8 in unit steps. Input types include J, K, T, E, R, S, B, N, DIN-J, RTD 100ohm with alpha of 0.00385 or 0.00392 0-20mA, 0- 100mV, 0-1V, and 0-10Vdc. Standard Alarm 1 output includes SPST relay, 5A @ 120Vac, 3A @ 240Vac.
OPTIONS
DESCRIPTION
ROUND CUTOUT (1 3/4" DIA.)
*
Omit for standard square 1/16 DIN cutout 
R
Round cutout with detachable NEMA 1 faceplate for fast, easy installation. Cutout diameter is 1.75" (44 mm)
PACKAGE CONFIGURATION
3
INFINITY® style NEMA 12 1/16 DIN bezel 1.89 sq. and standard 1/16 DIN 1.772" (45mm) sq. panel cutout
CONTROL OUTPUT 1
2
2 Solid state relay SSR: 1A @ 120/240 Vac continuous
3
Relay: form “C” 5A @ 120Vac, 3A @ 240Vac
4
Pulsed 10Vdc @ 20mA (use for external SSR)
5
Non-isolated 1 to 10Vdc or 0 to 20mA @500 ohm max
CONTROL OUTPUT 2
0
Enter “0” if second output is not needed
2
Solid state relay SSR: 1A @ 120/240 Vac continuous
3
Relay: 5A @ 120Vac, 3A @ 240Vac
4
4 Pulsed 10Vdc @ 20mA (use for external SSR)
OPTIONAL OUTPUT
*
None
-A2
Second Alarm, SPST relay, 5A @ 120 Vac, 3A @ 240Vac
-C2
Isolated RS 232, 300 to 19.2k baud
-C4
Isolated RS 485, 300 to 19.2k baud
-PV
Isolated Analog Output (scaled from process variable)
-RSP
Remote Setpoint selection
POWER SUPPLY
*
90 to 250 Vac/dc, 50 to 400 Hz (Standard)
ADD-ON OPTIONS
RHS43
Arbored holesaw 43mm (1 11/16") for ICN77R meters
TP4
Trimplate adapter to install 1/16 DIN meter in existing 1/4 DIN panel cutout
TP6
Trimplate adapter to install 1/16 DIN meter in existing 1/8 DIN panel cutout
Ordering Example: ICN77R323,C2 $279: Round panel cutout with relay as second control output, RS-232 communication and solid state relay (SSR) as control output 1.
Note: The controller must be ordered completely configured. Options are not field installable.


Model 205 Miniature 3/64 DIN Panel Meter with Full Size Display ---

STANDARD FEATURES 
  •  Zero and Span Adjustments of 2,000 Counts Each 
  •  ±1,999 -Count Display Span 
  •  120 dB CMR, 56 dB NMR 
  •  Bright, 14.2 mm (0.56") LED Display 
  •  EMI/RFI Filter for ac Power 
  •  Removable Screw-Clamp Connector 
  •  Miniature DIN Case with 24 x 72 mm (0.94" x 2.83") Bezel 
  OPTIONS 
  •  Isolated Transmitter Excitation Supply 
  •  4-20 mA, 1-5 V, 0-10 V Signal Ranges 
  •  Red or Green LED Display 
  •  24, 100, 115 or 230 Vac Power 
  •  25 x 75 mm (0.98 x 2.96") Bezel Adapter 
  •  NEMA-4 Splash-Proof Lens Cover 


 

Buy It Now ! Ordering Info

To Order :
 
Model Number
Description
205
( * )
3/64 DIN case
305
( * )
1/8 DIN case with INFINITY bezel
Input
Range Code
Range°F
Range°C
Resolution

Iron-Constantan
JC1-R, C0
JC2-R, C0
JF1-R, C0
JF2-R, C0
-346 to 1400°F
-199.9 to 199.9°F 
-210 to 760°C
-199.9 to 199.9°C
1°C / 0.1°C
1°F / 0.1°F 

Chromel-Alumel
KC1-R, C0
KC2-R, C0
KF1-R, C0
KF2-R, C0
-157 to 1999°F
-199.9 to 199.9°F
-105 to 1372°C
-199.9 to 199.9°C
1°C / 0.1°C
1°F / 0.1°F

Copper-Constantan
TC1-R, C0
TC2-R, C0
TF1-R, C0
TF2-R, C0
-157 to 752°F
-199.9 to 199.9°F 
-105 to 400°C
-199.9 to 199.9°C
1°C / 0.1°C
1°F / 0.1°F

Chromel-Constantan
EC1-R, C0
EC2-R, C0
EF1-R, C0
EF2-R, C0
-157 to 1832°F
-199.9 to 199.9°F
-105 to 1000°C
-199.9 to 199.9°C
1°C / 0.1°C
1°F / 0.1°F

100 ohm Pt
MC1-R, C0
MC2-R, C0
MF1-R, C0
MF2-R, C0
-328 to 1562°F
-199.9 to 199.9°F
-200 to 850°C
-199.9 to 199.9°C
1°C / 0.1°C
1°F / 0.1°F
To order with green display, change R to G in model number, no additional cost.

Power Options: for non-isolated 9-26 Vdc, change C0 to C2A in model number, no additional cost.
Ordering Example: 305-KC1-R-C0, type K meter, with -105 to 1372°C range, 1° resolution


202A/2002B Process, Strain, Temperature & Resistance Indicators/Controllers  ---

  • Full-Size 0.56" (14.2mm) red or green LED Display 
  • Field-scalability for process or strain inputs 
  • Linearization of thermocouple or RTD inputs 
  • Display hold and test 
  • Auto polarity 
  • EMI/RMI filter for AC power 
  • Screw-terminal barrier strip for power and signal 
  • Short 1/8 DIN case 
  • 202A: ±1,999 count display span (3-1/2 digit) 
  • 2002B: ±19,999 count display span (41/2 digit) 
MOST POPULAR MODELS : 
202A-P   DC volt or mA process receiver
202A-E   DC volt or mA process receiver with sensor excitation
202A-S   Strain gage indicator w/sensor excitation
202A-JF1   Type J T/C indicator, 1° resolution 
202A-KF1   Type K T/C indicator, 1° resolution

2002B-P    DC volt or mA process receiver 
2002B-KF1    Type K T/C indicator, 1° resolution


500 Series Two-Wire, Loop-Powered Process Indicators

Model 508B   ---


 
STANDARD FEATURES :
  •  FM, CSA, BASEEFA Intrinsic Safety Certification 
  •  Powered by 1-5, 4-20 or 10-50 mA Signal 
  •  2.5 V Max Voltage Drop 
  •  0.35 in (8.9 mm) Liquid Crystal Display 
  •  2,000-Count Zero Suppression or Elevation 
  •  100 to 2,000 Count Span Adjust 
  •  Selectable Dummy Right-Hand Zero 
  •  –40°C to +85°C Operation 
  •  Compact, 2.9 in Diameter Die-Cast Housing 
  •  Waterproof to 35 kPa (5 psi) 
  •  Shock Resistant to 55 g 
OPTIONS
  •  CENELEC Intrinsic Safety Certification, FM, CSA
  •  1/2 EMT Conduit Fitting
  •  1/2 NPT Pipe Fitting
  •  Relay-Track Mounting Adapters
  •  External Explosion-Proof Housing
  •  Companion Current Transmitters


Model 509   ---

  • Integral square-root extraction 
  • NEMA 4 die-cast metal housing, weatherproof to 5 PSI 
  • Temperature range -40 to +85°C 
MODELS 508B / 509
Model No.
TWO-WIRE, FM APPROVED, PROCESS LOOP INDICATOR IN NEMA-4 HOUSING
508B
Two-wire current-loop indicator that accepts 4-20 mA or 10-50 mA process signals and displays variables in percent or engineering units. Power is obtained from current loop. Standard features include -2000 to +2000 zero adjust, 3 1/2 digit (±1999) liquid-crystal display plus selectable dummy right-hand zero (±19990), -40 to +85°C operating temperature, and waterproof die-cast metal housing.
509
Same as above except computes square root of the input and displays the process variable in either percent or in engineering units.
OPTIONS
DESCRIPTION
MECHANICAL CONFIGURATION
-1
For mounting to flat surface or relay track. Connection via screw-terminal barrier strip (TB)
-2
For mounting to EMT conduit. Connection via two 0.3 meter long #18 wires; 1/2-inch EMT male pipe fitting
-3
For mounting to NPT pipe. Connection via two 0.3 meter long #18 wires; 1/2-inch NPT male pipe fitting
MOUNTING CONFIGURATION
*
Case alone for surface mount, for 63.5 mm (2.50 in) relay track or for use with MXS1 and explosion-proof housings
MAT1
Adapter plate for surface mount or 69.9 mm (2.75 in) relay track 
MDT1
Rail clamp for DIN relay track
CONFIGURATION AND CALIBRATION
*
Standard setup (readout from 000.0 to 100.0 for 4-20 mA input)
FS
Custom configuration and calibration. Specify min input, min reading; max input, max reading. Include decimal point and dummy right-hand zero (if selected)
SAFETY CERTIFICATION
*
FM IS certification label (standard)
IS1
CENELEC EEx ia certification label (508-B only)
ACCESSORIES
LB1
Loop break connector adapter provides continuity when device is removed from loop (508B-1 only) 
MXS1
Spring retainers for 508B-1 or 509-1 in explosion-proof housing EPW1 or EPW3, or 500 Series transmitter in explosion-proof housing EPW2
MXS2
Spring retainers for 508B-1 or 509-1 in explosion-proof housing EPW2
EPW3
External single height environmental enclosure with window for 508B-1 or 509-1, rated NEMA-7 (explosion-proof) and NEMA-4 (waterproof). Certified by FM and CENELEC. Includes internal mounting hardware MXS1
EPW2
External double-height environmental enclosure with window for one 508A-1 or 509-1 and one 500 Series transmitter for indicating two-wire applications. Rated NEMA-7 (explosion-proof) and NEMA-4 (water-proof). Includes FM and CENELEC certification and internal mounting hardware MXS1 and MXS2
MOST POPULAR MODEL
508B-1
3 1/2 digit LCD, 2-wire current loop indicator, configured to accept 4-20 mAdc input
$325.00


Model 558B ---


 
STANDARD FEATURES :
  •  Powered by 1-5 mA, 4-20 mA or 10-50 mA Signal 
  •  2.5 V Max Voltage Drop 
  •  Display to ±1,999, ±19,990 or ±199,900 
  •  0.5 inch (12.7 mm) Liquid-Crystal Display 
  •  100 to 2,000 Count Span Adjust 
  •  2,000-Count Zero Suppression or Elevation 
  •  Short 1/8 DIN Case 
  •  Simple 2-Wire Hook Up 
  •  Safe Plug-in Screw-Clamp Connector 
OPTIONS: 
  •  Intrinsic Safety Certification 
  •  –40 to +85°C Operating Temperature 
  •  NEMA-4 Splash-Proof Lens Cover 
MOST POPULAR MODELS :
558B         Two-wire current-loop indicator, 0 to +55° operating range
558B-ET   Two-wire current-loop indicator, -40 to +85° extended operating range

ADD-ON OPTIONS : 
BL      Lens without Newport logo
FS      Custom configuration and calibration. Specify min input, min reading; max input, max reading. Include decimal point and any dummy right-hand zeros
IS1      Intrinsic-safety certification with CENELEC EEx ia certification label
 


About...  |  Table of Contents  | Manufacturer Index  | What's New

Send Inquiries to:

Copyright © 2009 Davis Instruments. All rights reserved.