  McDonnell Miller Flow Switches 

FS4-3 Series General Purpose Flow Switches ---

  • Maximum pressure, 150 PSI 
  • Maximum temperature, 300°F 
  • Minimum temperature (fluid or ambient) 32°F 
  • Serves a wide variety of applications in air-conditioning, heating, water systems, and in processing work - wherever it is important to know when flow or no-flow occurs 
  • Switch: Single-pole, double throw Compact in size. Snap action assures dependable operation 
  • Adjusting Screw: Provides simple way to field adjust sensitivity to flow 
  • Packless: Monel bellows seals switch assembly from line 
  • 3-in-1 Paddle: Individual monel paddles are quickly adaptable for 1" to 3": pipe

FS7-4 Series Industrial Application Flow Switches ---

  • Now available in NEMA 4X (Watertight, Dust-tight, and Corrosion Resistant) Models; NEMA 7 and 9 Models (Hazardous Location); and Standard Models 
  • Available in either Brass or Stainless Steel construction 
  • Models FS7-4W and FS7-4SW (NEMA 4X) are ideal for outdoor use in ambient temperatures and/or fluid temperatures as low as -65°F 
  • Models FS7-4E and FS7-4E (NEMA 7 & 9) are Underwriters' Laboratories, Inc. Listed for use in Hazardous Locations 
  • Standard Models may be ordered in both single and double switch versions

FS8W Series General Purpose Flow Switch ---

  • Maximum pressure 150 PSI 
  • Maximum temperature, 225°F 
  • Minimum temperature (fluid or ambient) 32°F 
  • NEMA 4X (Watertight, Dust-tight, Corrosion Resistant) construction 
  • Particularly suited for use in areas of high humidity, and out-of-doors installation 
  • Individual paddles are adaptable for pipe 1" to 3", extended paddle for pipe to 6" is also included 
  • Installs in tee or welding neck in horizontal pipe; 1" threaded connection

AF1 Series Air Flow Switches for Duct Installation Medium and Higher Velocity ---

  • Maximum temperature 300°F; Minimum temperature 32°F 
  • Designed for medium and higher velocity systems 
  • AF1 units have a single-pole double-throw switch, can be wired to make one circuit, break a second circuit, when air flow starts or stops in a duct 
  • Can be installed in the side, top or bottom of a horizontal duct and, if necessary, in a vertical duct with upward air flow. If the only possible installation is in a vertical duct with downward air flow, contact Inotek for instructions, giving duct size and air flow velocities 
  • Stainless Steel; parts exposed to inside of duct are made of 18-8, 302 and 316 stainless steel, and Viton® (Registered trademark of DuPont Dow Elastomers) 
  • Switch compartment is sealed from duct by a Viton flexible rolling seal; this is a completely tight seal

FS1 Series High Sensitivity Flow Switches ---

  • FS1 offers an economical and dependable answer for many jobs inside buildings, such as air conditioning, heating/water systems and processing work 
  • FS1-W adds versatility to those characteristics by allowing use outdoors and in environments where humidity or airborn particles are a problem 
  • May be used with water, certain light, viscous liquids, fuel oil, and some oils 
  • Switch mechanism is magnetically activated and has no physical contact with the liquid 
  • Switch compartment is totally sealed from the liquid in the line and all wetted parts are brass, stainless steel, and Viton® (Registered trademark of DuPont Dow Elastomers) 
  • Threaded 1/2" on both inlet and outlet sides and requires no further pipe fittings 
  • FS1: Maximum pressure 100 PSI.; Maximum temperature 225°F; NEMA 1 Enclosure; Minimum Fluid/Ambient Temperature 32°F 
  • FS1-W: Maximum pressure 100 PSI.; Maximum temperature 225°F; NEMA 4X Enclosure; Minimum Fluid/Ambient Temperature 32°F