Martel Voltage, Frequency, Current Calibrators
T110 Voltage Calibrator ---
|
-
High Accuracy/Source and Read Capability
-
Rugged, Dust Tight, Water Resistant Case
-
Easy to Read Super-Twist LCD
-
Intuitive Controls make operation
-
Easy even for infrequent users
-
Powered by a common 9 Volt battery
|
The Tuff-Tools line of calibrators is designed to give the technician
laboratory grade accuracy in a family of rugged, easy to use instruments.
The Tuff-Tools family consists of 3 Process Signal calibrators (mA,
Volts, Frequency), 2 Temperature calibrators (T/C, RTD) and a Pressure
calibrator available in several ranges (200" H 2 O, 30 PSI, 100 PSI).
Operation of these calibrators is made easy through the use of a sealed
membrane keypad with simple controls. The outputs are set through the use
of step and ramp keys which allows both large and small output changes
to be made with ease.
Each Unit Includes: Test leads, carrying case, 9V battery, NIST Certificate,
and instruction manual.
| Voltage - T110 |
| Range: |
0.0
to 100.0 mV
0.00 to 10.00 V |
| Operating Modes: |
Read or Source |
| Accuracy¹ : |
± 0.025%
FS ± 1 LSD |
| Operating Temp.: |
0 to 50°C |
| Storage Temp.: |
-20 to 60°C |
| Temperature Stability²: |
.01% F.S./°C |
| Step Size: |
10 mV or 1 V
(10 per range) |
| Scroll Size: |
.1 mV or .01
V |
| Load Capacity: |
± 1 mA |
| Weight: |
12 oz. |
| Size: |
1.43" x 3.15"
x 5.7" |
Note 1: 18°C
to 28°C
Note 2: 0 to 18°C and 28°C to 50°C |
|
T150 Frequency Calibrator ---
|
-
High Accuracy/Source and Read Capability
-
Rugged, Dust Tight, Water Resistant Case
-
Easy to Read Super-Twist LCD
-
Intuitive Controls make operation
-
Easy even for infrequent users
-
Powered by a common 9 Volt battery
|
| Frequency - T150 |
| Range: |
0-100.0
kHz
0-1000.0 Hz
0-1000.0 CPM |
| Accuracy¹ : |
± 0.01%
F.S. ± 1 LSD |
| Max Load Driving: |
5 mA (1 Kohm load min) |
| Operating Temp.: |
0 to 50°C |
| Storage Temp.: |
-20 to 60°C |
| Temperature Stability²: |
.005% F.S./°C |
| Output Signal: |
5 V p-p square
wave |
| Input Signal: |
1 V to 100 V
p-p |
| Step Size: |
10% of range |
| Scroll Size: |
.1% of Range |
| Weight: |
12 oz. |
| Size: |
1.43" x 3.15"
x 5.7" |
Note 1: 18°C
to 28°C
Note 2: 0 to 18°C and 28°C to 50°C |
|
T100 Milliamp Calibrator ---

Ordering Info
|
-
High Accuracy/Source and Read Capability
-
Rugged, Dust Tight, Water Resistant Case
-
Easy to Read Super-Twist LCD
-
Intuitive Controls make operation
-
Easy even for infrequent users
-
Powered by a common 9 Volt battery
|
| Milliamp - T100 |
| Range: |
0.00
to 24.00 mA
25.0% to 125.0% |
| Operating Modes: |
Source, Simulate,
Read, Read/Power |
| Accuracy¹ : |
± 0.01%
F.S. ± 1 LSD |
| Operating Temp.: |
0 to 50°C |
| Storage Temp.: |
-20 to 60°C |
| Temperature Stability²: |
.01% F.S./°C |
| Loop Power: |
24V DC |
| Step Size: |
4 mA (0, 4,
8, 12, 16, 20 and 24) Input Signal: 1 V to 100 V p-p |
| Scroll Size: |
.01 mA |
| Weight: |
12 oz. |
| Size: |
1.43" x 3.15"
x 5.7" |
Note 1: 18°C
to 28°C
Note 2: 0 to 18°C and 28°C to 50°C |
|
IVC-222HPII Voltage / Current Calibrator ---

Ordering Info
|
The all new IVC-222HPII is a general-purpose current and voltage source
that can be used in engineering, manufacturing; test and process control
applications. It combines the latest digital and analog circuitry to achieve
it’s rated specifications in a small, reliable package.
This unit has the capability to store and recall up to two values in
the set-points provided by the SP1 and SP2 keys.
The IVC-222HPII has a RS-232 port which can be accessed via a custom
cable available from Martel allowing the unit to be computer controlled
for automated testing.
-
Remarkable 0.015% of reading accuracy
-
Four ranges; 200 mV, 2 V, 20 V, and 24 mA
-
Intuitive, easy to use controls
-
RS-232 interface - can be computer controlled
-
Built-in 24 volt supply can drive 4 to 20 mA loops over 1000 ohms
-
Rugged, lightweight, hand-held case
Each Unit Includes: Test leads, carrying case, 9V battery, NIST Certificate,
and instruction manual. |
| General Specifications: |
| |
Voltage Output |
mA Output |
| Output Range: |
200 mV 2 V 20 V |
24 mA |
| Resolution: |
0.01 mV 0.1 mV 1 mV |
mA |
| Accuracy 18°C to 28°C: |
±0.015% of Reading
±2 count |
|
| Temperature Stability: |
0 to 18°C
28 to 50°C |
|
| Load Capability: |
±1 mA for rated accuracy |
1000 ohms |
| Capacitive Load: |
No limitations |
N/A |
| Output Protection: |
Current limited Internal
Resett |
|
| Power: |
9V Alkaline battery or optional
NiCd |
|
| Case Dimensions: |
1.43" x 3.15" x 5.7" |
|
| Weight: |
12 oz. |
|
| Size: |
1.43" x 3.15" x 5.7" |
|
|
| Range |
Min. |
Max. |
Accuracy (% of reading
± counts) |
| mV |
0.00 |
200.00 |
0.015% ± 2 |
| V |
0.0000
0.000 |
2.0000
20.000 |
0.015% ± 2
0.015% ± 2 |
| mA |
0.000 |
24.000 |
0.015% ± 2 |
|
Optional Accessories:
| Model |
Description |
| C232SJ |
RS-232 Cable |
| 1002-9V |
NiCd Battery |
| 1001-9V |