Martel
Temperature Calibrators
TC100 Precision Thermocouple Calibrator ---
|
-
High accuracy - ±0.3°C
-
(Type J T/C - all errors combined)
-
Ten (10) common T/C types plus mV
-
Accepts both T/C mini-plug and bare T/C wires
-
Simple decade control of output
-
Three (3) setpoints for each T/C type
-
MIN/MAX recall in measure mode
-
Input protection to 240 VAC
|
The Martel Electronics TC-100 Thermocouple Calibrator provides high
accuracy source and measurement of ten common thermocouples, as well as
mV. The TC-100's accuracy of ±0.3°C for Type J T/Cs includes
all errors, at resolutions of ±0.01°C or °F in measure mode
and ±0.1°C or °F in source mode. Features including MIN/MAX
recall in measure mode, three setpoints per thermocouple range, a large
knob for decade control of the output in source mode, and the ability to
accept bare T/C wires in addition to mini-plug inputs, makes the TC-100
an accurate, easy-to-use instrument for all your thermocouple calibration
needs.
| General Specifications: |
| (1 year at 23°C ±5°C;
% of reading unless otherwise noted) |
| Output Voltage |
| |
Range: |
-10 to +75.000 mV |
| Resolution: |
1 µV |
| Accuracy: |
±0.007 % of reading,
±10 µV |
| Output Impedance: |
&Mac178;1 Ohm |
| Input Voltage: |
| |
Range: |
-10 to +75.000 mV |
| Resolution: |
1 µV |
| Accuracy: |
±0.007 % of reading,
±10 µV |
| Output Impedance: |
Input Impedance > 1 MegOhm |
| Thermocouple
Source/Measure: |
| |
Types: |
J, K, T, E, R, S, B, L,
U, C |
| Range: |
mV |
| Resolution |
|
Source: |
±0.1°C or °F |
|
Measure |
±0.01°C or °F |
| Accuracy: |
| J |
±0.5 °C; -210
°C to -100 °C
±0.3 °C; -100 °C to +1,200 °C |
| K |
±0.6 °C; -200
°C to -100 °C
±0.35 °C; -100 °C to +1,000 °C
±0.5 °C; +1,000 °C to +1,372 °C |
| T |
±0.7 °C; -200
°C to -150 °C
±0.3 °C; -150 °C to +400 °C |
| E |
±0.5 °C; -200
°C to -100 °C
±0.3 °C; -100 °C to +1,000 °C |
| R |
±1.8 °C; 0 °C
to 250 °C
±1.0 °C; 250 °C to +1,767 °C |
| S |
±1.8 °C; 0 °C
to 250 °C
±1.0 °C; 250 °C to +1,767 °C |
| B |
±1.7 °C; 600
°C to 1,000 °C
±1.2 °C; 1,000 °C to 1,820 °C |
| L |
±0.5 °C; -200
°C to -100 °C
±0.4 °C; -100 °C to +900 °C |
| U |
±0.7 °C; -200
°C to 0 °C
±0.3 °C; 0 °C to +600 °C |
| C |
±0.4 °C; 0 to
°C 1,000 °C
±0.7 °C; 1,000 °C to +1,800 °C
±1.2 °C; +1,800 °C to +2,316 °C |
| CJC
Temperature Offset: |
±0.05 °C/°C outside
of 23±5 °C |
| Warm-up
Time: |
1 minute to specification |
| Environmental: |
| |
Operating: |
-10 °C to +55 °C |
| Storage: |
-20 °C to +70 °C |
| Power Requirements: |
| Battery: |
9 Volt alkaline; 006P/ IEC
6F22/ NEDA1604
Optional NiCad
Optional AC adapter/charger |
| Mechanical
Dimensions: |
5.7" x 3.15" x 1.43"
(14.47 cm x 8.00 cm x 3.63 cm) |
| Weight: |
12 ounces (340 grams) |
| Notes: |
| 1. Temperature
standard ITS-90. |
|
PTC8001 High Accuracy Temperature Calibrator
---
"Smart" Transmitter Compatible
|
-
High accuracy ±0.4°C J T/C and ±0.3°C 4W PT385
RTD all errors included
-
10 T/C types and 8 RTD types including PT 385 (1000 ohm) and cu (10
ohm)
-
Direct keyboard entry or scroll control of output
-
Nema 4 rated case, rugged design
-
RTD simulation works with all pulsed (smart) transmitters
-
YSI 400 series thermistor range for medical applications
-
Standard mini-plug or banana jack connections for T/C
-
Store up to nine setpoints for each output function
-
RS232 Interface
|
The Martel PTC-8001 Precision Temperature Calibrator is an ideal device
to handle all of your temperature calibration needs in a truly rugged,
low cost package. It combines virtually all widely used thermocouples and
RTDs in one device—you’ll never have to worry about finding a temperature
device you can’t calibrate.
This is especially true when calibrating “smart” or pulsed RTD transmitters
where many other calibra-tors fail to work or operate at reduced accuracy
specs. The PTC-8001 handles those applications with ease.
Each Unit Includes: Test leads, carrying case, 4 AA alkaline batteries,
NIST Certificate, and instruction manual.
Note: For T/C please order
T/C cable kit; Model 80029 for $89.00
| General Specifications: |
| T/C Ranges: |
J, K, T, E, R, S, N, B,
L, U including – 10 to 70 mV range |
| RTD Ranges: |
Pt 385 (100, 200, 500, 1000
ohms)
Pt 392, JIS, Ni 120, CU10, YSI 400 |
| Ohms Ranges: |
0 to 400.00 and 400.0 to
4000.0 |
| Accuracy: |
T/C Type J: ±.3°C
±10
V (±0.6°C total error)
RTD PT100: ±.1°C ±.075
(±0.3°C total error)
Ohms (400): ±0.1
Ohms (4000): ±1.0  |
| RTD IEX-range: |
0.01 mA to 3 mA |
| RTD Frequency Response: |
10 mS – works with all pulsed XMTR’s |
| Oper. Temp: |
-10°C to 50°C |
| Storage Temp: |
-20°C to 60°C |
| Power Supply: |
4 AA Alkaline Cells, 30
hours typical operating time |
| Size: |
7.5" x 4" x 1.5" |
|
| Range: |
Min |
Max |
Accuracy |
|
| Ohms Read 4w
(low): |
0.00 |
400.00 |
0.1 ohm |
|
| Ohms Read 4w
(high): |
400.0
1500.0 |
1500.0
4000.0 |
0.5 ohm
1.0 ohm |
|
| Ohms Ranges: |
|
|
|
|
| Range: |
Min |
Max |
Excitation Current |
Accuracy |
| Ohms Source
(low): |
5.00
5.00 |
400.00
400.00 |
0.1 to 0.5 mA
0.5 to 3 mA |
0.15 ohm
0.1 ohm |
| Ohms Source
(high): |
400.0
1500.0 |
1500.0
4000.0 |
0.05 to 0.8 mA
0.05 to 0.4 mA |
0.5 ohm
1.0 ohm |
|
| RTD Read and Source |
| Range: |
Min |
Max |
Accuracy |
| Ni120 (672) |
-80.0 |
260.0 |
0.2°C |
| Pt100 (385) |
-200.0 |
800.0 |
0.33°C |
| Pt100(3926) |
-200.0 |
630.0 |
0.3°C |
| Pt100(3916) |
-200.0 |
630.0 |
0.3°C |
| Pt200(385) |
-200.0
100.0 |
630.0 |
0.8°C |
| Pt500(385) |
-200.0
500.0 |
500.0
630.0 |
0.3°C
0.4°C |
| Pt1000(385) |
-200.0
100.0 |
100.0
630.0 |
0.2°C
0.3°C |
| Cu10 |
-100.0 |
250.0 |
2.2°C |
| YSI400 |
15.00 |
50.00 |
0.05°C |
|
| Thermocouple Read and
Source (All errors included) |
| Range: |
Min |
Max |
Accuracy |
| J Thermocouple |
-200.0
0.0 |
0.0
1200.0 |
0.6°C
0.4°C |
| K Thermocouple |
-200.0
0.0 |
0.0
1370.0 |
0.8°C
0.5°C |
| T Thermocouple |
-200.0
0.0 |
0.0
400.0 |
0.8°C
0.5°C |
| E Thermocouple |
-200.0
0.0 |
0.0
950.0 |
0.5°C
0.4°C |
| R Thermocouple |
-20
0
50.0 |
0.0
500
1750 |
2.4°C
1.7°C
1.3°C |
|
| Range: |
Min. |
Max. |
Accuracy |
| S Thermocouple |
-20
0
500 |
-20
0
1750 |
2.4°C
1.7°C
1.4°C |
| B Thermocouple |
600
8000
1000 |
800
1000
1800 |
2.1°C
1.7°C
1.3°C |
| L Thermocouple |
-200.0
0.00 |
0.0
900.0 |
0.45°C
0.4°C |
| U Thermocouple |
-200.0
0.00 |
0.0
400.0 |
0.7°C
0.45°C |
| N Thermocouple |
-200.0
0.00 |
0.0
1300.0 |
1.1°C
0.6°C |
| mV Read/Source |
-10.00 |
75.00 |
0.015% ±
2 |
|
PTC9002 Precision Temperature Calibrator
---
with Simultaneous mA Input Capability
|
-
High Accuracy on 4 T/C and 3 RTD Ranges
-
Direct Keyboard Entry of Data
-
63 Point Calibration Memory
-
Simultaneous Display of Temperature Output and 4-20 mA Input
-
Built-in 24 Volt Loop Power Supply
|
The Martel PTC-9002 is a full func-tion thermocouple/RTD calibrator
com-bined with the ability to simultaneously read and display a 4 to 20
mA current loop. These features make it ideal for calibrating all types
of temperature measuring devices and transmitters.
Housed in a rugged hand-held case, the PTC-9002 features 0.5°C accuracy
on the most commonly used T/C and RTD ranges. Up to nine (9) setpoints
can be stored in non-volatile memory for each of the seven ranges. An auto-step
function allows the user to automatically step through each of the stored
setpoints for a particular range at a predetermined interval.
Resolution is .1°C/.1°F on all tem-perature ranges and .001mA
on the mil-liamp range. An internal 24 volt loop power supply allows the
user to power a two-wire transmitter and read the out-put current. No external
loop power is required.
Each Unit Includes: Test leads, carrying case, 4 alkaline AA batteries,
instruction manual, and NIST Certificate.
| General Specifications: |
| Pressure Ranges: |
Various ranges in 29 different
pressure modules – see Pressure Module Ranges: Specifications |
| T/C Ranges: |
J,K,T,E,R,S,N,B,L,U including
-10 to70 mV |
| RTD Ranges: |
Pt 385 (100, 200, 500, 1000
ohms)
Pt 392, JIS, Ni120, CU10, YSI400 |
| Ohms Ranges: |
0 to 400.00 and 400.0 to
4000.0 |
| mA Range: |
0 to 24.000 mA |
| Voltage: |
(Low) Read 0-20.000 VDC
Source 0-10.000 VDC
(High) Read only 0-250 VDC or VAC |
| Frequency: |
0-1000.0 CPM
0-1000.0 Hz
0-10.00 KHz |
| Continuity: |
0 to 400.0 ohms, audible
tone when under 10 ohms |
| Accuracy: |
T/C Type J: ±.3°C
±10 m V
(±0.4°C total error)
RTD PT100: ±.1°C ±.075
(±0.3°C total error)
Ohms (400): ±0.1
Ohms (4000): ±1.0  |
| mA Compliance: |
Up to 1000
load |
| Voltage Drive
Capability: |
1 mA |
| RTD IEX-range: |
0.01 mA to 3 mA |
| RTD Frequency
Response: |
10 mS – works with all pulsed
XMTR’s |
| Oper. Temp: |
-10°C to 50°C |
| Storage Temp: |
-20°C to 70°C |
| Loop Power: |
4 AA alkaline batteries,
25 hours typical operating time |
| Size: |
7.5" x 4" x 1.5" |
|
Tuff-Tools - T120 / T130
Single Function Thermocouple & RTD Calibrators
---
T120 - Thermocouple
T130 - RTD
|
The Tuff-Tools line of calibrators is designed to give the technician
laboratory grade accuracy in a family of rugged, easy to use instruments.
Operation of these calibrators is made easy through the use of a sealed
membrane keypad with simple controls. The outputs are set through the use
of step and ramp keys which allows both large and small output changes
to be made with ease.
Each Unit Includes: Test leads, carrying case, 9V battery, NIST Certificate,
and instruction manual.
Note: For T120 please order
T/C cable kit for test leads.
-
High Accuracy/Source and Read Capability
-
Rugged, Dust Tight, Water Resistant Case
-
Easy to Read Super-Twist LCD
-
Intuitive Controls make operation Easy even for infrequent users
-
Powered by a common 9 Volt battery
|
| Thermocouple - T120 |
| Range: |
J
K
T
E |
-100 to 1000°C
-100 to 1200°C
-100 to 400°C
-100 to 950°C
Selectable °C or °F |
| Resolution: |
1°C or °F |
| Accuracy¹ : |
±1°C
above 0°C
±2°Cbelow 0°C manual |
| Operating Temp.: |
0 to 50°C |
| Storage Temp.: |
-20 to 60°C |
| Temperature Stability: |
.01% F.S./°C |
| Step Size: |
100°C/100°F |
| Scroll Size: |
1°C/1°F |
| Weight: |
12 oz. |
| Size: |
1.43" x 3.15"
x 5.7" |
Note 1: 18°C
to 28°C
Note 2: 0 to 18°C and 28°C to 50°C |
|
| RTD - T130 |
| Range: |
Pt
385
Pt 392
Ni 120
JIS 392 |
-200 to 850°C
-200 to 850°C
-80 to 320°C
-200 to 850°C
Selectable °C or °F |
| Resolution: |
1°C or °F |
| Accuracy¹ : |
±1°C |
| Operating Temp.: |
0 to 50°C |
| Storage Temp.: |
-20 to 60°C |
| Temperature Stability: |
.01% F.S./°C |
| Step Size: |
100°C/100°F |
| Scroll Size: |
1°C/1°F |
| Excitation Range: |
0.125 mA to
2 mA
continuous DC |
| Weight: |
12 oz. |
| Size: |
1.43" x 3.15"
x 5.7" |
Note 1: 18°C
to 28°C
Note 2: 0 to 18°C and 28°C to 50°C |
|
Thermocouple Kit ---
 |
Ideal for use with MC-1000, PTC-8001 and T120 calibrators. Martel part
number 80029.
All cables are terminated with a standard mini-connector on one end
and bbare leads on the other.
80029 KIT INCLUDES:
-
Type J T/C cable
-
Type T T/C cable
-
Type K T/C cable
-
Type E T/C cable
|
|