Contact the closest office: 1-800-358-5525

  

MadgeTech Wireless RF Data Loggers 

MH101RFTRANS

 

MH101RFTRANS Radio Frequency Receiver 

FEATURES

  • Compatible with all RF series Transmitters
  • Receive data from multiple units with single setup
  •  Fast and user friendly
  •  Real-Time operation
  •  FCC and IC approved
  • Connects to standard RS-232 DB9 serial port

The MH101RFTRANS is a wireless receiver for MadgeTech's RF series data transmitters. The interface cable enables users to receive and analyze data in real-time from a wireless transmitter. It interfaces with the MadgeTech software via a standard RS-232 9-pin serial port.

Interface           RS-232, DB-9 female serial connector
RF Carrier Frequency           418 MHz
Radio Type           Amplitude Modulating (AM)
Power           7V to 18V DC, wall adapter included
Range           up to 120 ft line of sight
Approvals           US (FCC), CA (IC)
Software           Windows 95/98/NT/ME/2000/XP based software
Operating Environment           0 °C to +70 °C, 10 to 90 %RH non-condensing
Dimensions           0.8 x 1.7 x 2.3 + cable (20mm x 42mm x 59mm + cable)


MH101-RF

 

MH101-RF

FEATURES

  • 0.1 ºC resolution, 0.5 ºC accuracy
  • 8,191 reading storage
  • Multiple transmitter configurations
  • Memory wrap around
  • Software configurable
  • Real-Time operation
  • Programmable start time
  • Miniature size
  • User friendly
  • N.I.S.T. Traceable

The MH101-RF is a battery powered temperature recorder and wireless transmitter. It combines the features from the standard product line and adds the convenience of a wireless transmitter. When enabled, the wireless transmitter will transmit readings back to the host computer where the data can be analyzed in real time. These readings are also logged to the device's memory for added data security.

Temperature Sensor Semiconductor
Temperature Range -30 °C to +70 °C
Temperature Resolution 0.1 °C
Calibrated Accuracy ±0.5 °C (0 to +50 °C)
Start Time Software programmable start time. Up to six months in advance.
Real-time Recording May be used with PC to monitor and record data in real time
Reading Interval 1 reading every 30 seconds to one reading every 12 hours
Memory 8,191 readings
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
RF Baud Rate 4,800 baud
RF Carrier Frequency 418 MHz
Range up to 120 ft line of sight
Approvals US (FCC), CA (IC)
Power 3.6V lithium battery included
User Replaceable Battery 1 year typical (1 min reading rate @ 25 ºC)
Data Format Date and time stamped °C, °F, °K, °R
Time Accuracy ±1 minute/month (at 20 ºC to 30 ºC)
Computer Interface PC serial or RS232C COM (interface cable required); 57,600 baud
Software Windows 95/98/NT/ME/2000/XP based software
Operating Environment -30 °C to +70 °C, 5 to 95 %RH non-condensing
Dimensions 0.8 x 1.7 x 2.3 (20mm x 42mm x 59mm)
Weight 2 oz (60 g)


MH4000TC-RF

 

MH4000TC-RF 

FEATURES

  • Accepts thermocouple types J,K,T,E,R,S,B,N
  • Female subminiature connection (SMP)
  • 4,095 reading storage per channel
  • Multiple transmitter configurations
  • Memory wrap around
  • Software configurable
  • Real-Time operation
  • Programmable start time
  • Miniature size
  • User friendly
  • N.I.S.T. Traceable

The MH4000TC-RF is a battery powered thermocouple recorder and wireless transmitter. It combines the features from the standard product line and adds the convenience of a wireless transmitter. When enabled, the wireless transmitter will transmit readings back to the host computer where the data can be analyzed in real time. These readings are also logged to the device's memory for added data security.

Internal Channel
Temperature Range
-30 °C to +70 °C
Temperature Resolution 0.1 °C
Calibrated Accuracy ±0.5 °C @ 25 ºC
Remote Channel
Thermocouple Types
J,K,T,E,R,S,B,N
Thermocouple Connection Female subminiature (SMP); Others available upon request
Cold Junction
Compensation
Automatic, based on internal channel
Start Time Software programmable start time. Up to six months in advance.
Real-time Recording May be used with PC to monitor and record data in real time
Reading Interval 1 reading every 30 seconds to one reading every 12 hours
Memory 4,095 readings per channel
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
RF Baud Rate 4,800 baud
RF Carrier Frequency 418 MHz
Range up to 120 ft line of sight
Approvals US (FCC), CA (IC)
Power 3.6V lithium battery included
User Replaceable Battery 1 year typical (1 min reading rate @ 25 ºC)
Data Format Date and time stamped °C, °F, °K, °R; V, mV, µV
Time Accuracy ±1 minute/month (at 20 ºC to 30 ºC)
Computer Interface PC serial or RS232C COM (interface cable required); 57,600 baud
Software Windows 95/98/NT/ME/2000/XP based software
Operating Environment -30 °C to +70 °C, 5 to 95 %RH non-condensing
Dimensions 0.8 x 1.7 x 2.3 (20mm x 42mm x 59mm)
Weight 2 oz (60 g)

MH101RTD-RF

 

MH101RTD-RF

FEATURES

  • 0.01 ºC resolution, ±0.05 ºC accuracy
  • -200 ºC to +850 ºC measurement range
  • 5,461 reading storage
  • Multiple transmitter configurations
  • Memory wrap around
  • Software configurable
  • Real-Time operation
  • Programmable start time
  • Miniature size
  • User friendly
  • N.I.S.T. Traceable

The MH101RTD-RF is a battery powered precision temperature recorder and wireless transmitter. It combines the features from the standard product line and adds the convenience of a wireless transmitter. When enabled, the wireless transmitter will transmit readings back to the host computer where the data can be analyzed in real time. These readings are also logged to the device's memory for added data security.

Temperature Measurement Range -200 °C to +850 °C
Temperature Resolution 0.01 °C
Calibrated Accuracy ±0.05 °C @ 25 °C
Specified Accuracy Range -200 °C to +850 °C
Resistance Nominal Range 0 ohms to 5000 ohms
Resistance Resolution 0.001 ohms
Calibrated Accuracy ±0.015 ohms
Specified Accuracy Range 0 to 500 ohms at 25 °C
Start Time Software programmable start time. Up to six months in advance.
Real-time Recording May be used with PC to monitor and record data in real time
Reading Interval 1 reading every 30 seconds to one reading every 12 hours
Memory 5,461 readings
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
RF Baud Rate 4,800 baud
RF Carrier Frequency 418 MHz
Range up to 120 ft line of sight
Approvals US (FCC), CA (IC)
Power 3.6V lithium battery included
User Replaceable Battery 1 year typical (1 min reading rate @ 25 ºC)
Data Format Date and time stamped °C, °F, °K, °R; ohms
Time Accuracy ±1 minute/month (at 20 ºC to 30 ºC)
Computer Interface PC serial or RS232C COM (interface cable required); 57,600 baud
Software Windows 95/98/NT/ME/2000/XP based software
Operating Environment -30 °C to +70 °C, 5 to 95 %RH non-condensing
Dimensions 0.8 x 1.7 x 2.3 (20mm x 42mm x 59mm)
Weight 2 oz (60 g)
**Temperature specifications based on 100 Ohm Pt RTD compliant with IEC 751 (1983) and ITS-90

MH101RH-RF

 

MH101RH-RF

FEATURES

  • 0.1 ºC resolution, ±0.5 ºC accuracy (0 to +50 ºC)
  • 0.5 %RH resolution, 3 %RH accuracy
  • 5,461 reading storage
  • Multiple transmitter configurations
  • Memory wrap around
  • Software configurable
  • Real-Time operation
  • Programmable start time
  • Miniature size
  • User friendly
  • N.I.S.T. Traceable

The MH101RH-RF is a battery powered humidity and temperature recorder with a wireless transmitter. It combines the features from the standard product line and adds the convenience of a wireless transmitter. When enabled, the wireless transmitter will transmit readings back to the host computer where the data can be analyzed in real time. These readings are also logged to the device's memory for added data security.

Temperature Sensor Semiconductor
Temperature Range -30 °C to +70 °C
Temperature Resolution 0.1 °C
Calibrated Accuracy ±0.5 °C (0 to +50 °C)
Humidity Sensor Semiconductor
Humidity Range 0 to 100 %RH
Humidity Resolution 0.5 %RH
Calibrated Accuracy ±3 %RH (±2% RH typical at 25 ºC)
Start Time Software programmable start time. Up to six months in advance.
Real-time Recording May be used with PC to monitor and record data in real time
Reading Interval 1 reading every 30 seconds to one reading every 12 hours
Memory 5,461 readings
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
RF Baud Rate 4,800 baud
RF Carrier Frequency 418 MHz
Range up to 120 ft line of sight
Approvals US (FCC), CA (IC)
Power 3.6V lithium battery included
User Replaceable Battery 1 year typical (1 min reading rate @ 25 ºC)
Data Format Date and time stamped °C, °F, °K, °R; %RH, mg/ml water vapor concentration
Time Accuracy ±1 minute/month (at 20 ºC to 30 ºC)
Computer Interface PC serial or RS232C COM (interface cable required); 57,600 baud
Software Windows 95/98/NT/ME/2000/XP based software
Operating Environment -30 °C to +70 °C, 5 to 95 %RH non-condensing
Dimensions 0.8 x 1.7 x 2.3 (20mm x 42mm x 59mm)
Weight 2 oz (60 g)

MH101V-RF

 

MH101V-RF

FEATURES

  • 100 mV, 15 V and 30 V ranges available
  • User definable engineering units
  • 8,191 reading storage
  • Multiple transmitter configurations
  • Memory wrap around
  • Software configurable
  • Real-Time operation
  • Programmable start time
  • Miniature size
  • User friendly
  • N.I.S.T. Traceable

The MH101V-RF is a battery powered voltage recorder and wireless transmitter. It combines the features from the standard product line and adds the convenience of a wireless transmitter. When enabled, the wireless transmitter will transmit readings back to the host computer where the data can be analyzed in real time. These readings are also logged to the device's memory for added data security.

Input Connection Removable screw terminal
Voltage Range ±100 mV, -1.0 to 16.0 V, -2.0 to 32.0 V
Voltage Resolution 5 µV, 0.5 mV, 1.0 mV
Calibrated Accuracy ±0.01 (%FSR), ±0.10 (%FSR), ±0.10 (%FSR)
Start Time Software programmable start time. Up to six months in advance.
Real-time Recording May be used with PC to monitor and record data in real time
Reading Interval 1 reading every 30 seconds to one reading every 12 hours
Memory 8,191 readings
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
RF Baud Rate 4,800 baud
RF Carrier Frequency 418 MHz
Range up to 120 ft line of sight
Approvals US (FCC), CA (IC)
Power 3.6V lithium battery included
User Replaceable Battery 1 year typical (1 min reading rate @ 25 ºC)
Data Format Date and time stamped, V, mV, V, engineering units specified through software
Time Accuracy ±1 minute/month (at 20 ºC to 30 ºC)
Computer Interface PC serial or RS232C COM (interface cable required); 57,600 baud
Software Windows 95/98/NT/ME/2000/XP based software
Operating Environment -30 °C to +70 °C, 5 to 95 %RH non-condensing
Dimensions 0.8 x 1.7 x 2.3 (20mm x 42mm x 59mm)
Weight 2 oz (60 g)


MH101MA-RF

 

MH101MA-RF

FEATURES

  • ±1 mA, ±25 mA and ±100 mA ranges available
  • User definable engineering units
  • 8,191 reading storage
  • Multiple transmitter configurations
  • Memory wrap around
  • Software configurable
  • Real-Time operation
  • Programmable start time
  • Miniature size
  • User friendly
  • N.I.S.T. Traceable

The MH101MA-RF is a battery powered current recorder and wireless transmitter. It combines the features from the standard product line and adds the convenience of a wireless transmitter. When enabled, the wireless transmitter will transmit readings back to the host computer where the data can be analyzed in real time. These readings are also logged to the device's memory for added data security.

Input Connection Removable screw terminal
Current Range ±1 mA, ±25 mA, ±100 mA
Current Resolution 0.05 µA, 1 µA, 5 µA
Calibrated Accuracy ±0.5 (%FSR), ±0.10 (%FSR), ±0.10 (%FSR)
Input Resistance 50 ohms, 10 ohms, 2 ohms
Start Time Software programmable start time. Up to six months in advance.
Real-time Recording May be used with PC to monitor and record data in real time
Reading Interval 1 reading every 30 seconds to one reading every 12 hours
Memory 8,191 readings
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
RF Baud Rate 4,800 baud
RF Carrier Frequency 418 MHz
Range up to 120 ft line of sight
Approvals US (FCC), CA (IC)
Power 3.6V lithium battery included
User Replaceable Battery 1 year typical (1 min reading rate @ 25 ºC)
Data Format Date and time stamped, A, mA, µA, engineering units specified through software
Time Accuracy ±1 minute/month (at 20 ºC to 30 ºC)
Computer Interface PC serial or RS232C COM (interface cable required); 57,600 baud
Software Windows 95/98/NT/ME/2000/XP based software
Operating Environment -30 °C to +70 °C, 5 to 95 %RH non-condensing
Dimensions 0.8 x 1.7 x 2.3 (20mm x 42mm x 59mm)
Weight 2 oz (60 g)


MH101PH-RF

 

MH101PH-RF

FEATURES

  • 0.01 pH (0.1 mV) resolution
  • ±0.1 pH (1.0 mV) accuracy
  • 13,107 reading storage
  • Multiple transmitter configurations
  • Memory wrap around
  • Software configurable
  • Real-Time operation
  • Programmable start time
  • Miniature size
  • User friendly
  • N.I.S.T. Traceable

The MH101PH-RF is a battery powered pH and temperature recorder with a wireless transmitter. It combines the features from the standard product line and adds the convenience of a wireless transmitter. When enabled, the wireless transmitter will transmit readings back to the host computer where the data can be analyzed in real time. These readings are also logged to the device's memory for added data security.

Temperature Measurement Range -200 °C to +850 °C
Temperature Resolution 0.01 °C
Calibrated Accuracy ±0.05 °C @ 25 °C
Specified Accuracy Range -200 °C to +850 °C
pH Measurement Range 0.00 to 14.00 pH (-1000 to +1000 mV)
pH Resolution 0.01 pH (0.1 mV)
Calibrated Accuracy ±0.1 pH (±1 mV)
pH Input Connection Female BNC jack
Start Time Software programmable start time. Up to six months in advance.
Real-time Recording May be used with PC to monitor and record data in real time
Reading Interval 1 reading every 30 seconds to one reading every 12 hours
Memory 13,107 readings per channel
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
RF Baud Rate 4,800 baud
RF Carrier Frequency 418 MHz
Range up to 120 ft line of sight
Approvals US (FCC), CA (IC)
Power 3.6V lithium battery included
User Replaceable Battery 1 year typical (1 min reading rate @ 25 ºC)
Data Format Date and time stamped ºC, ºF, ºK, ºR, ohms; pH, V, mV, engineering units specified through software
Time Accuracy ±1 minute/month (at 20 ºC to 30 ºC)
Computer Interface PC serial or RS232C COM (interface cable required); 57,600 baud
Software Windows 95/98/NT/ME/2000/XP based software
Operating Environment -5 °C to +50 °C, 5 to 95 %RH non-condensing
Dimensions 4.5 x 2.4 x 1.0 x (114mm x 61mm x 25mm)
Weight 4 oz (120 g)
**Temperature specifications based on 100 Ohm Pt RTD compliant with IEC 751 (1983) and ITS-90


About...  |  Table of Contents  | Manufacturer Index  | What's New

Send Inquiries to:

Copyright © 2006 Davis Inotek Instruments, LLC. All rights reserved.