Contact the closest office: 1-800-358-5525 |
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
MH101RFTRANS Radio Frequency Receiver |
FEATURES
|
The MH101RFTRANS is a wireless receiver for MadgeTech's RF series data transmitters. The interface cable enables users to receive and analyze data in real-time from a wireless transmitter. It interfaces with the MadgeTech software via a standard RS-232 9-pin serial port.
Interface RS-232, DB-9 female serial connector
RF Carrier Frequency 418 MHz
Radio Type Amplitude Modulating (AM)
Power 7V to 18V DC, wall adapter included
Range up to 120 ft line of sight
Approvals US (FCC), CA (IC)
Software Windows 95/98/NT/ME/2000/XP based software
Operating Environment 0 °C to +70 °C, 10 to 90 %RH non-condensing
Dimensions 0.8 x 1.7 x 2.3 + cable (20mm x 42mm x 59mm + cable)
MH101-RF |
FEATURES
|
The MH101-RF is a battery powered temperature recorder and wireless transmitter. It combines the features from the standard product line and adds the convenience of a wireless transmitter. When enabled, the wireless transmitter will transmit readings back to the host computer where the data can be analyzed in real time. These readings are also logged to the device's memory for added data security.
| Temperature Sensor | Semiconductor |
| Temperature Range | -30 °C to +70 °C |
| Temperature Resolution | 0.1 °C |
| Calibrated Accuracy | ±0.5 °C (0 to +50 °C) |
| Start Time | Software programmable start time. Up to six months in advance. |
| Real-time Recording | May be used with PC to monitor and record data in real time |
| Reading Interval | 1 reading every 30 seconds to one reading every 12 hours |
| Memory | 8,191 readings |
| Calibration | Digital calibration through software |
| Calibration Date | Automatically recorded within device |
| RF Baud Rate | 4,800 baud |
| RF Carrier Frequency | 418 MHz |
| Range | up to 120 ft line of sight |
| Approvals | US (FCC), CA (IC) |
| Power | 3.6V lithium battery included |
| User Replaceable Battery | 1 year typical (1 min reading rate @ 25 ºC) |
| Data Format | Date and time stamped °C, °F, °K, °R |
| Time Accuracy | ±1 minute/month (at 20 ºC to 30 ºC) |
| Computer Interface | PC serial or RS232C COM (interface cable required); 57,600 baud |
| Software | Windows 95/98/NT/ME/2000/XP based software |
| Operating Environment | -30 °C to +70 °C, 5 to 95 %RH non-condensing |
| Dimensions | 0.8 x 1.7 x 2.3 (20mm x 42mm x 59mm) |
| Weight | 2 oz (60 g) |
MH4000TC-RF |
FEATURES
|
The MH4000TC-RF is a battery powered thermocouple recorder and wireless transmitter. It combines the features from the standard product line and adds the convenience of a wireless transmitter. When enabled, the wireless transmitter will transmit readings back to the host computer where the data can be analyzed in real time. These readings are also logged to the device's memory for added data security.
| Internal Channel Temperature Range |
-30 °C to +70 °C |
| Temperature Resolution | 0.1 °C |
| Calibrated Accuracy | ±0.5 °C @ 25 ºC |
| Remote Channel Thermocouple Types |
J,K,T,E,R,S,B,N |
| Thermocouple Connection | Female subminiature (SMP); Others available upon request |
| Cold Junction Compensation |
Automatic, based on internal channel |
| Start Time | Software programmable start time. Up to six months in advance. |
| Real-time Recording | May be used with PC to monitor and record data in real time |
| Reading Interval | 1 reading every 30 seconds to one reading every 12 hours |
| Memory | 4,095 readings per channel |
| Calibration | Digital calibration through software |
| Calibration Date | Automatically recorded within device |
| RF Baud Rate | 4,800 baud |
| RF Carrier Frequency | 418 MHz |
| Range | up to 120 ft line of sight |
| Approvals | US (FCC), CA (IC) |
| Power | 3.6V lithium battery included |
| User Replaceable Battery | 1 year typical (1 min reading rate @ 25 ºC) |
| Data Format | Date and time stamped °C, °F, °K, °R; V, mV, µV |
| Time Accuracy | ±1 minute/month (at 20 ºC to 30 ºC) |
| Computer Interface | PC serial or RS232C COM (interface cable required); 57,600 baud |
| Software | Windows 95/98/NT/ME/2000/XP based software |
| Operating Environment | -30 °C to +70 °C, 5 to 95 %RH non-condensing |
| Dimensions | 0.8 x 1.7 x 2.3 (20mm x 42mm x 59mm) |
| Weight | 2 oz (60 g) |
MH101RTD-RF |
FEATURES
|
The MH101RTD-RF is a battery powered precision temperature recorder and wireless transmitter. It combines the features from the standard product line and adds the convenience of a wireless transmitter. When enabled, the wireless transmitter will transmit readings back to the host computer where the data can be analyzed in real time. These readings are also logged to the device's memory for added data security.
| Temperature Measurement Range | -200 °C to +850 °C |
| Temperature Resolution | 0.01 °C |
| Calibrated Accuracy | ±0.05 °C @ 25 °C |
| Specified Accuracy Range | -200 °C to +850 °C |
| Resistance Nominal Range | 0 ohms to 5000 ohms |
| Resistance Resolution | 0.001 ohms |
| Calibrated Accuracy | ±0.015 ohms |
| Specified Accuracy Range | 0 to 500 ohms at 25 °C |
| Start Time | Software programmable start time. Up to six months in advance. |
| Real-time Recording | May be used with PC to monitor and record data in real time |
| Reading Interval | 1 reading every 30 seconds to one reading every 12 hours |
| Memory | 5,461 readings |
| Calibration | Digital calibration through software |
| Calibration Date | Automatically recorded within device |
| RF Baud Rate | 4,800 baud |
| RF Carrier Frequency | 418 MHz |
| Range | up to 120 ft line of sight |
| Approvals | US (FCC), CA (IC) |
| Power | 3.6V lithium battery included |
| User Replaceable Battery | 1 year typical (1 min reading rate @ 25 ºC) |
| Data Format | Date and time stamped °C, °F, °K, °R; ohms |
| Time Accuracy | ±1 minute/month (at 20 ºC to 30 ºC) |
| Computer Interface | PC serial or RS232C COM (interface cable required); 57,600 baud |
| Software | Windows 95/98/NT/ME/2000/XP based software |
| Operating Environment | -30 °C to +70 °C, 5 to 95 %RH non-condensing |
| Dimensions | 0.8 x 1.7 x 2.3 (20mm x 42mm x 59mm) |
| Weight | 2 oz (60 g) |
| **Temperature specifications based on 100 Ohm Pt RTD compliant with IEC 751 (1983) and ITS-90 | |
MH101RH-RF |
FEATURES
|
The MH101RH-RF is a battery powered humidity and temperature recorder with a wireless transmitter. It combines the features from the standard product line and adds the convenience of a wireless transmitter. When enabled, the wireless transmitter will transmit readings back to the host computer where the data can be analyzed in real time. These readings are also logged to the device's memory for added data security.
| Temperature Sensor | Semiconductor |
| Temperature Range | -30 °C to +70 °C |
| Temperature Resolution | 0.1 °C |
| Calibrated Accuracy | ±0.5 °C (0 to +50 °C) |
| Humidity Sensor | Semiconductor |
| Humidity Range | 0 to 100 %RH |
| Humidity Resolution | 0.5 %RH |
| Calibrated Accuracy | ±3 %RH (±2% RH typical at 25 ºC) |
| Start Time | Software programmable start time. Up to six months in advance. |
| Real-time Recording | May be used with PC to monitor and record data in real time |
| Reading Interval | 1 reading every 30 seconds to one reading every 12 hours |
| Memory | 5,461 readings |
| Calibration | Digital calibration through software |
| Calibration Date | Automatically recorded within device |
| RF Baud Rate | 4,800 baud |
| RF Carrier Frequency | 418 MHz |
| Range | up to 120 ft line of sight |
| Approvals | US (FCC), CA (IC) |
| Power | 3.6V lithium battery included |
| User Replaceable Battery | 1 year typical (1 min reading rate @ 25 ºC) |
| Data Format | Date and time stamped °C, °F, °K, °R; %RH, mg/ml water vapor concentration |
| Time Accuracy | ±1 minute/month (at 20 ºC to 30 ºC) |
| Computer Interface | PC serial or RS232C COM (interface cable required); 57,600 baud |
| Software | Windows 95/98/NT/ME/2000/XP based software |
| Operating Environment | -30 °C to +70 °C, 5 to 95 %RH non-condensing |
| Dimensions | 0.8 x 1.7 x 2.3 (20mm x 42mm x 59mm) |
| Weight | 2 oz (60 g) |
MH101V-RF |
FEATURES
|
The MH101V-RF is a battery powered voltage recorder and wireless transmitter. It combines the features from the standard product line and adds the convenience of a wireless transmitter. When enabled, the wireless transmitter will transmit readings back to the host computer where the data can be analyzed in real time. These readings are also logged to the device's memory for added data security.
| Input Connection | Removable screw terminal |
| Voltage Range | ±100 mV, -1.0 to 16.0 V, -2.0 to 32.0 V |
| Voltage Resolution | 5 µV, 0.5 mV, 1.0 mV |
| Calibrated Accuracy | ±0.01 (%FSR), ±0.10 (%FSR), ±0.10 (%FSR) |
| Start Time | Software programmable start time. Up to six months in advance. |
| Real-time Recording | May be used with PC to monitor and record data in real time |
| Reading Interval | 1 reading every 30 seconds to one reading every 12 hours |
| Memory | 8,191 readings |
| Calibration | Digital calibration through software |
| Calibration Date | Automatically recorded within device |
| RF Baud Rate | 4,800 baud |
| RF Carrier Frequency | 418 MHz |
| Range | up to 120 ft line of sight |
| Approvals | US (FCC), CA (IC) |
| Power | 3.6V lithium battery included |
| User Replaceable Battery | 1 year typical (1 min reading rate @ 25 ºC) |
| Data Format | Date and time stamped, V, mV, V, engineering units specified through software |
| Time Accuracy | ±1 minute/month (at 20 ºC to 30 ºC) |
| Computer Interface | PC serial or RS232C COM (interface cable required); 57,600 baud |
| Software | Windows 95/98/NT/ME/2000/XP based software |
| Operating Environment | -30 °C to +70 °C, 5 to 95 %RH non-condensing |
| Dimensions | 0.8 x 1.7 x 2.3 (20mm x 42mm x 59mm) |
| Weight | 2 oz (60 g) |
MH101MA-RF |
FEATURES
|
The MH101MA-RF is a battery powered current recorder and wireless transmitter. It combines the features from the standard product line and adds the convenience of a wireless transmitter. When enabled, the wireless transmitter will transmit readings back to the host computer where the data can be analyzed in real time. These readings are also logged to the device's memory for added data security.
| Input Connection | Removable screw terminal |
| Current Range | ±1 mA, ±25 mA, ±100 mA |
| Current Resolution | 0.05 µA, 1 µA, 5 µA |
| Calibrated Accuracy | ±0.5 (%FSR), ±0.10 (%FSR), ±0.10 (%FSR) |
| Input Resistance | 50 ohms, 10 ohms, 2 ohms |
| Start Time | Software programmable start time. Up to six months in advance. |
| Real-time Recording | May be used with PC to monitor and record data in real time |
| Reading Interval | 1 reading every 30 seconds to one reading every 12 hours |
| Memory | 8,191 readings |
| Calibration | Digital calibration through software |
| Calibration Date | Automatically recorded within device |
| RF Baud Rate | 4,800 baud |
| RF Carrier Frequency | 418 MHz |
| Range | up to 120 ft line of sight |
| Approvals | US (FCC), CA (IC) |
| Power | 3.6V lithium battery included |
| User Replaceable Battery | 1 year typical (1 min reading rate @ 25 ºC) |
| Data Format | Date and time stamped, A, mA, µA, engineering units specified through software |
| Time Accuracy | ±1 minute/month (at 20 ºC to 30 ºC) |
| Computer Interface | PC serial or RS232C COM (interface cable required); 57,600 baud |
| Software | Windows 95/98/NT/ME/2000/XP based software |
| Operating Environment | -30 °C to +70 °C, 5 to 95 %RH non-condensing |
| Dimensions | 0.8 x 1.7 x 2.3 (20mm x 42mm x 59mm) |
| Weight | 2 oz (60 g) |
MH101PH-RF |
FEATURES
|
The MH101PH-RF is a battery powered pH and temperature recorder with a wireless transmitter. It combines the features from the standard product line and adds the convenience of a wireless transmitter. When enabled, the wireless transmitter will transmit readings back to the host computer where the data can be analyzed in real time. These readings are also logged to the device's memory for added data security.
| Temperature Measurement Range | -200 °C to +850 °C |
| Temperature Resolution | 0.01 °C |
| Calibrated Accuracy | ±0.05 °C @ 25 °C |
| Specified Accuracy Range | -200 °C to +850 °C |
| pH Measurement Range | 0.00 to 14.00 pH (-1000 to +1000 mV) |
| pH Resolution | 0.01 pH (0.1 mV) |
| Calibrated Accuracy | ±0.1 pH (±1 mV) |
| pH Input Connection | Female BNC jack |
| Start Time | Software programmable start time. Up to six months in advance. |
| Real-time Recording | May be used with PC to monitor and record data in real time |
| Reading Interval | 1 reading every 30 seconds to one reading every 12 hours |
| Memory | 13,107 readings per channel |
| Calibration | Digital calibration through software |
| Calibration Date | Automatically recorded within device |
| RF Baud Rate | 4,800 baud |
| RF Carrier Frequency | 418 MHz |
| Range | up to 120 ft line of sight |
| Approvals | US (FCC), CA (IC) |
| Power | 3.6V lithium battery included |
| User Replaceable Battery | 1 year typical (1 min reading rate @ 25 ºC) |
| Data Format | Date and time stamped ºC, ºF, ºK, ºR, ohms; pH, V, mV, engineering units specified through software |
| Time Accuracy | ±1 minute/month (at 20 ºC to 30 ºC) |
| Computer Interface | PC serial or RS232C COM (interface cable required); 57,600 baud |
| Software | Windows 95/98/NT/ME/2000/XP based software |
| Operating Environment | -5 °C to +50 °C, 5 to 95 %RH non-condensing |
| Dimensions | 4.5 x 2.4 x 1.0 x (114mm x 61mm x 25mm) |
| Weight | 4 oz (120 g) |
| **Temperature specifications based on 100 Ohm Pt RTD compliant with IEC 751 (1983) and ITS-90 | |