Hart Scientific Dry
Well Calibration Equipment
Hart Scientific 9009
Industrial Dual-Block Calibrator
 |
Feature Summary
-
Temperatures from –15°C to 350°C in
one unit
-
Two wells in each block for simultaneous comparison
calibrations
-
Rugged, lightweight, water-resistant enclosure
-
Controlled by precision Hart Scientific temperature
controller
Ordering Info
|
The Model 9009 includes two independently
controlled temperature blocks. The hot block provides temperatures
from 50°C to 350°C, while the cold block covers the range –15°C
to 110°C. Each block is controlled by a precision Hart Scientific
temperature controller. These aren’t some off-the-shelf controllers
we glued into a box. These are Hart Scientific controllers from the
leading temperature company in the world.
Each temperature block includes two wells
with removable inserts. You can calibrate four probes at once, or
you can calibrate two probes at the same time with an external reference
(like Hart’s Model 1521 LLK Thermometer), or you can use the two temperature
wells to get quick “zero” and “span” references for transmitter calibrations.
The 9009 is housed in a tough Pelican™
case that is both airtight and watertight. It’s a small package weighing
only 10 pounds, yet it fits everything you need, including a power cord
and four extra inserts. Inserts are available to accommodate sensors
of any size from 1/16" (1.6 mm) to 7/16” (11.1 mm). This rugged system
can go anywhere.
| Specifications |
Hot Block
|
Cold Block
|
| Range |
50°C to 350°C (122°F to
662°F)
|
–15°C to 110°C (5°F to
230°F)
(–8°C [18°F] with hot block at
350°C [662°F])
|
| Accuracy |
±0.6°C
|
±0.2°C
|
| Stability |
±0.05°C
|
| Well-to-Well
Uniformity |
±0.1°C
|
| Display
Resolution |
0.1°
|
| Heating
Times |
10 minutes from 25°C to 350°C
|
15 minutes from 25°C to 110°C
|
| Cooling
Times |
30 minutes from 350°C to 100°C
|
16 minutes from 25°C to –15°C
|
| Stabilization
Times |
8 minutes
|
| Well Depth |
4" (102 mm)
|
| Removable
Inserts |
Two 1/4” (6.4 mm) and 3/16” (4.8 mm)
inserts included; see Ordering Information for other available inserts
|
| Computer
Interface |
RS-232 included with free Interface-it
software
|
| Power |
115 VAC (±10%), 3 A, or
230 VAC (±10%), 2 A, specify,
50/60 Hz, 250 W
|
| Size |
7" H x 10.5" W x 9.75" D (178 x 267
x 248 mm)
|
| Weight |
10 lb. (4.5 kg)
|
| NIST-Traceable
Calibration |
Data at 50°C, 100°C, 150°C,
200°C, 250°C, 300°C, and 350°C
|
Data at –8°C, 0°C, 25°C,
50°C, 75°C, 100°C, and 110°C
|
Hart Scientific Field
Dry Well Calibrators
 |
Models 9103, 9140, and
9141
-
RS-232 and Interface-it software included
|
These three units beat every other comparable
dry-well in the industry in performance, size, weight, convenience, ease
of calibration, software, and price. In addition, the heating and
cooling rate of each of these dry-wells is adjustable from the front panel,
thermal switches can be checked for actuation testing, and multiple-hole
inserts are available for a variety of probe sizes.
Hart dry-wells are easy to calibrate.
You don’t even have to open the case. This means less maintenance
costs and less down time when they do need calibration.
Our Interface-it software lets you adjust
set-points and ramp rates, log dry-well readings to a file, create an electronic
strip chart, and perform thermal switch testing with data collection.
The software is written for Windows and has a great graphical interface.
It’s the best dry-well software in the industry. Regardless of whether
you want basic software or a completely automated calibration system, we’ve
got what you want.
| Specifications |
9103
|
9140
|
9141
|
| Range |
–25°C to 140°C (–13°F
to 284°F)
at 23°C ambient
|
35°C to 350°C (95°F to
662°F)
|
50°C to 650°C (122°F to
1202°F)
|
| Accuracy |
±0.25°C
|
±0.5°C (holes greater than
1/4" [6.35 mm]: ±1°C)
|
±0.5°C to 400°C; ±1.0°C
to 650°C
(holes greater than 1/4": ±2°C)
|
| Stability |
±0.02°C at –25°C
±0.04°C at 140°C
|
±0.03°C at 50°C
±0.05°C at 350°C
|
±0.05°C at 100°C
±0.10°C at 500°C
±0.12°C at 650°C
|
| Well-to-Well
Uniformity |
±0.1°C between similarly
sized wells
|
±0.1°C with similarly sized
wells
|
±0.1°C below 400°C,
±0.5°C above 400°C with similarly sized wells
|
| Heating
Times |
18 minutes from ambient to 140°C
|
12 minutes from ambient to 350°C
|
12 minutes from ambient to 650°C
|
| Cooling
Times |
20 minutes from ambient to –25°C
|
15 minutes from 350°C to 100°C
|
25 minutes from 650°C to 100°C
|
| Stabilization
Time |
7 minutes
|
| Immersion
Depth |
4.875” (124 mm)
|
| Inserts |
Insert A, B, or C included (specify
when ordering)
|
| Computer
Interface |
RS-232 included with free Interface-it
software (Model 9930)
|
| Power |
115 VAC (±10%), 1.3 A or 230
VAC (±10%), 0.7 A, switchable, 50/60 Hz, 150 W
|
115 VAC (±10%), 4.4 A or 230
VAC (±10%), 2.2 A, switchable, 50/60 Hz, 500 W
|
115 VAC (±10%), 8.8 A or 230
VAC (±10%), 4.4 A, switchable, 50/60 Hz, 1000 W
|
| Size |
5.63" W x 10.25" H x 9.63" D
(143 x 261 x 245 mm)
|
6" W x 3.375" H x 7.75" D
(152 x 86 x 197 mm)
|
4.3" W x 9.3" H x 7.3" D
(109 x 236 x 185 mm)
|
| Weight |
12 lb. (5.7 kg)
|
6 lb. (2.7 kg)
|
8 lb. (3.6 kg)
|
| NIST-Traceable
Certificate |
Data at –25°C, 0°C, 25°C,
50°C, 75°C, 100°C, and 140°
|
Data at 50°C, 100°C, 150°C,
200°C, 250°C, 300°C, and 350°C
|
Data at 100°C, 200°C, 300°C,
400°C, 500°C, and 600°C
|
Hart Scientific High
Accuracy Dry-Wells
Model 9105 Low Temp
includes 1/4" insert
Model 9107 Ultra Low
Temp includes 1/4" insert
Model 9122 High Capacity
includes 1/8", 3/16", 3/8", and 1/4" inserts
Model 9107 High Speed
includes multi-hole insert (specify)
Features:
-
World’s best dry-wells—accurate to 0.1°C,
stable to ±0.005°C
-
Largest-capacity temperature wells
-
Model 9107 reaches lowest temperatures: –45°C
in 23°C ambient
-
Model 9122A provides temperatures to 700°C
| Specifications |
9105 |
9107 |
9122A |
9127 |
| Range |
–25°C to 140°C
(–13°F to 284°F)
at 23°C ambient |
–45°C to 140°C
(–49°F to 284°F)
at 23°C ambient |
50°C to 700°C†
(122°F to 1292°F) |
50°C to 600°C
(122°F to 1112°F) |
| Accuracy |
Center well:
±0.1°C |
Center well:
±0.1°C |
Center well:
±0.1°C at 100°C
±0.1°C at 300°C
±0.3°C at 660°C |
±0.1°C
at 100°C
±0.15°C at 300°C
±0.5°C at 600°C
|
| Stability |
±0.01°C |
±0.01°C
at –40°C
±0.005°C at 0°C
±0.005°C at 100°C |
±0.01°C
at 100°C
±0.02°C at 300°C
±0.05°C at 660°C |
±0.01°C
to 100°C
±0.02°C to 300°C
±0.05°C to 600°C |
| Well-to-Well Uniformity |
Drilled wells:
±0.05°C |
Drilled wells:
±0.05°C |
Drilled wells:
±0.025°C at 100°C
±0.1°C at 300°C
±0.3°C at 660°C |
±0.05°C |
| Well Depth |
6" (152 mm)
|
| Computer Interface |
RS-232 Interface included
with Model 9930 Interface-it control software, IEEE optional |
| Heating Time to Max. |
10 minutes |
15 minutes |
75 minutes |
30 minutes |
| Cooling Time |
25°C to –25°C:
15 minutes |
25°C to –45°C:
35 minutes |
700°C to 100°C:
280 minutes |
600°C to 100°C:
125 minutes |
| Test Wells |
5 wells: 2 at
1/4" (6.35 mm), 1 at 3/16" (4.8 mm), 1 at 1/8" (3.2 mm), and 1 interchangeable
(3/4"/19.1 mm O.D.) |
5 wells: 2 at
1/4" (6.35 mm), 1 at 3/16" (4.8 mm), 1 at 1/8" (3.2 mm), and 1 interchangeable
(3/4"/19.1 mm O.D.) |
9 wells: 4 interchangeable
(3/4"/19.1 mm O.D.) and 5 at 1/4" (6.35 mm) |
1 interchangeable
well accommodates multi-hole insert (1.5"/38.1 mm O.D.) |
| Resolution |
0.01°C or °F |
| Display |
LED, °C or
°F, user-selectable |
| Size |
13.5" H x 7.8"
W x 11.9" D (343 x 198 x 302 mm) |
| Weight |
26 lb. (11.8 kg) |
22 lb. (10 kg) |
25 lb. (11.3 kg) |
25 lb. (11.3 kg) |
| Power |
115 VAC (±10%),
3 A or 230 VAC (±10%), 1.6 A, specify, 50/60 Hz, 350 W |
115 VAC (±10%),
4 A or 230 VAC (±10%), 3.15 A, specify, 50/60 Hz, 350 W |
115 VAC (±10%),
8.8 A or 230 VAC (±10%), 4.4 A, specify, 50/60 Hz, 1000 W |
115 VAC (±10%),
8.8 A or 230 VAC (±10%), 4.4 A, switchable, 50/60 Hz, 1000 W |
| NIST-Traceable
Calibration |
Data at –25°C,
0°C, 75°C, and 140°C |
Data at –45°C,
0°C, 75°C, and 140°C |
Data at 100°C,
200°C, 300°C, 400°C, 500°C, and 660°C |
Data at 100°C,
200°C, 300°C, 400°C, 500°C, and 600°C |
| †Calibrated to
660°C; reference thermometer recommended at higher temperatures. |
Hart Scientific Calibration
Furnace --- 1200 °C
 |
Thermocouple Furnace
Model 9150
-
Low-cost thermocouple furnace
-
NIST-traceable calibration included
-
RS-232 port standard
With a stability of ±0.5°C,
it has a temperature range to 1200°C and a display accuracy of ±5°C
across its entire range.
Ordering Info
|
With interchangeable temperature blocks,
you can check thermocouples as small as 1/16 of an inch in diameter. The
9150 works with 115 or 230 VAC power.
|
 |
| Specifications |
| Temperature
Range |
150°C to 1200°C
(302°F to 2192°F) |
| Display
Resolution |
0.1° to 999.9°
1° above 1000° |
| Stability |
±0.5°C |
| Display
Accuracy |
±5°C |
| Well Diameter |
1.25" (32 mm) |
| Well Depth |
4" (102 mm) |
| Heating
Time |
35 minutes to 1200°C |
| Cooling
Time |
140 minutes with block |
| Well-to-Well
Uniformity |
±0.5°C to ±1.0°C
(Insert “C” at 1200°C) |
| Stabilization |
20 minutes |
| Power |
115 VAC (±10%), 10.5
A or 230 VAC (±10%), 5.2 A, switchable, 50/60 Hz, 1200 W |
| Size |
12.4" H x 8.2" W x 12.4" D
(315 x 208 x 315 mm) |
| Weight |
28 lb. (13 kg) |
| NIST-Traceable
Calibration |
Data at 150°C, 300°C,
450°C, 600°C, 800°C, 1000°C, 1200°C |
|