Contact the closest office: 1-800-358-5525 |
|
|
The 5100 Series Hall effect portable gaussmeters represent the most recent design from the world leader in |

Ordering Info |
Model
|
5060
|
5070
|
5080
|
|
Probe
Included
|
Yes
|
Yes
|
Yes
|
|
Auto
Zero
|
Yes
|
Yes
|
Yes
|
|
Min/Max
Hold
|
-
|
Yes
|
Yes
|
|
True
RMS
|
-
|
Yes
|
Yes
|
|
Auto
Range
|
-
|
Yes
|
Yes
|
|
True
Peak Hold
|
-
|
-
|
Yes
|
|
Relative
Mode
|
-
|
-
|
Yes
|
|
Outputs
(Analog)
|
-
|
-
|
Yes
|
|
Communication
Port
|
-
|
-
|
Yes
|
|
Model
|
5060
|
5070
|
5080
|
|
Basic
Accuracy
|
4%
|
2%
|
1%
|
|
Frequency
Bandwidth
|
dc
|
dc
- 10 kHz
|
dc
- 20 kHz
|
|
Sampling
Rate
|
-
|
10/sec
|
10/sec
|
|
Ranges
|
(2)
|
(2)
|
(3)
|
|
Low
Range
|
2
kG
|
200
G
|
300
G
|
|
Mid Range
|
-
|
2
kG
|
3
kG
|
|
High Range
|
20
kG
|
20
kG
|
30
kG
|
|
Resolution
|
|||
|
Low
Range
|
1.0
G (100 uT)
|
0.1
G (10 uT)
|
0.1
G (10 uT)
|
|
Mid Range
|
-
|
1.0
G (100 uT)
|
1.0
G (100 uT)
|
|
High Range
|
10
G (1 mT)
|
10
G (1 mT)
|
10
G (1 mT)
|
|
Display
|
LCD
|
LCD
|
LCD
|
|
Digits
|
3
1/2
|
3
1/2
|
3
3/4
|
|
Readings
|
Gauss
Tesla
|
GaussTesla
Ampere/Meters
|
GaussTesla
Ampere/Meters
|
|
Analog
Output
|
-
|
-
|
3V
F.S.
|
|
Communication
Port
|
-
|
-
|
RS-232
|
|
Model |
4090 4080 |
4070 |
|
# of Axes |
Three Three |
Single |
|
Auto Ranging |
Yes |
Yes |
No |
Available Options |
A, D, F20, X01,T F50,T |
F20,F50 |
|
Minimum Resolution |
0.1mG 0.1mG |
0.1mG |
|
Measuring Range |
0.1 to 1999 mG (std)
0.1 - 511 mG (std)
|
0.1 - 199.9 mG |
|
Typical Accuracy Error |
± (1% + 1 digit) ± (2% + 1 digit) |
± (1% + 1 digit) |
|
Frequency Response
±5%
-3 dB |
50-300 Hz
30/600 Hz 40-600 Hz
25/1000 Hz |
40-200 Hz
30/600 Hz |
|
Calibration Frequency |
55 Hz 60 Hz |
60 Hz * |
|
Display |
3 1/2 digit LCD 3 1/2 digit LCD |
3 1/2 digit LCD |
|
Measurement Type |
True RMS True RMS |
True RMS |
|
Battery Life (Typical) |
50 Hours 40 Hours |
250 Hours |
|
Operating Temperature |
-10°C to+50°C 0°C to+50°C |
0°C to+50°C |
|
Power Source |
9V alkaline 9V alkaline |
9V alkaline |
|
Weight |
7 oz. 5 oz. |
5 oz. |
|
Size |
5.9" H
3.2" W 1.2" D 4.7" H |
4.7" H
2.4" W 1.0" D |
Options Summary F20 - Extended Bandwidth This option extends the frequency response of the instrument to 20-2,000 Hz. This is useful if measurements are required for sources with high harmonic content.(*) F50 - 50 Hz Calibration For instruments for use outside of North America, this no-cost option changes the standard calibration frequency from 60 Hz to 50 Hz.A - Analog Output This option provides a buffered output for viewing the analog waveform on an oscilloscope, spectrum analyzer, or similar test equipment. This is useful for determining harmonic content and other waveform properties. (z -axis only)D- DC Output This option provides a voltage level proportional to the displayed level of the magnetic field. It is useful for driving chart recorders, data loggers, and other data acquisition equipment.X01 - Switchable Single Axis Mode This option allows users to display the vector components of the magnetic field. This option should be specified in applications that require the direction of the magnetic field to be known as well as the level. T - Microtesla Scale Instruments ordered with this option display the magnetic field in µT (instead of mG). |
|
|
Features
|
About... | Table of Contents | Manufacturer Index | What's New Send Inquiries to: |