   Fluke AC Current Clamps

 AC Current Clamps
 AC/DC Current Clamps


Fluke AC Current Clamps

i200 200A Clamp, Current Output, Banana ---

Small sized, convenient-to-use current clamp

The i200 is a single range 200A ac current clamp with current output via safety shrouded banana plugs. The i200 is compatible with any Fluke multimeter or any other current measurement device that accepts shrouded banana plugs.
  • Measuring range: 0.5 to 240A 
  • The output signal is 1 mA/A
  • Safety shrouded banana plugs for use with DMMs or any other current measuring device which has banana inputs
  • Maximum current 240A ac
  • 40 Hz to 10 kHz frequency response
  • EN61010, CAT III 600V
  • One year warranty


i200s 200Amp AC Current Clamp, Voltage Output, BNC ---

The i200s is a dual range 20A and 200A ac current clamp with voltage output via a safety insulated BNC connector. A dual banana to BNC adapter is supplied to allow the i200s to be connected to multimeters with banana inputs.
 

  • Measuring range: 0.1 to 24A and 0.5 to 240A 
  • The output signal is 100 mV/A in the 20A range and 10 mV/A in the 200A range 
  • Includes BNC connector making it suitable for use with any oscilloscope, power analyzer or ScopeMeter" test tool having a compatible BNC input connector
  • Dual banana to BNC adapter is included for use with DMMs
  • Maximum current 240A ac
  • 40 Hz to 10 kHz frequency response
  • Jaw opening 21 mm
  • Maximum conductor size 20 mm dia. or busbar 20 x 5 mm
  • EN61010, CAT III 600V
  • One year warranty

80i-400 Clamp-On AC Current Probe ---

Measures ac current from 1A to 400A. Output to meter is 1mA/Amp ac. (1000 to 1 division ratio.) Maximum conductor size: one 1.18" (30 mm) or two each 0.98" (25 mm). Accuracy: ¤(3%+0.4A) from 48 Hz to 440 Hz.


80i-600A Clamp-On AC Current Probe ---

------------- Buy It Now !  Ordering Info

Measures ac current from 1A to 600A. Output to meter is 1mA/Amp ac. (Division ratio is 1000 to 1.) Maximum conductor size 2" (50 mm) in diameter. New straight, safety-shrouded plugs. Accuracy: ¤2%, 50 Hz to 1 kHz, ¤3% (typical) 30 Hz to 50 Hz or 1 kHz to 10 kHz. (Factory Mutual Approved)


i1000s Current Oscilloscope Clamp ---

  • 206 mm L X 105 mm W X 48 mm D, approximately 650g in weight 
  • 2A to 1000 A continuos AC Current Range (2000A peak) 
  • 0.5A to 1000A, 2% of reading; 0.1A to 10A, 3% of reading, (5 mA 
  • 5 Hz to 100 kHz usable frequency range 
  • 600V AC RMS working voltage 
  • 600V AC RMS output cable and connector to ground 
  • 1 mV/Amp, 10 mV/Amp, and 100 mV/Amp output levels 
  • One year warranty 

i 3000s Current Clamp ---

Measures ac current from 1A to 2400A RMS continuous. Accuracy 1-30A - 2% of reading + 0.1A, 1-300A - 2% of reading + 0.5A, 1-3000A - 2% of reading + 2A. PM9081/001 BNC to banana adapter included
.


i2000Flex Current Accessory ---

Features at a Glance:

  • Measures up to 2000A ac
  • Switchable between 200A and 2000A
  • Includes a 62 cm (24.4") circumference flexible probe with a connector for coupling and decoupling around a conductor
  • Includes BNC connector, making it suitable for use with any oscilloscope, power analyzer or ScopeMeter test tool having a compatible BNC input connector
  • Dual banana to BNC adapter is included for use with DMMs
  • CAT III 600V
  • The output signal is 10 mV/A in the 200A range and 1 mV/A in the 2000A range
  • Bandwidth (-3dB): 1 Hz to 20 kHz
  • 9V alkaline battery, installed 
  • At least 100 hour battery life
  • One year warranty
  • UL approval is pending

For current measurement on large and difficult to reach conductors


The i2000flex is a flexible, ac current probe for oscilloscopes and digital multimeters recommended for current measurement on large and difficult to reach conductors or grouped cables. 
 
 


Fluke AC / DC Current Clamps

80i-110s 70Amp AC / 100Amp DC Current Clamp ---


Battery-powered Hall-effect clamp-on probe measures ac current to 70A, dc current to 100A. Output is 10 mV/A, 100mV/A.  Maximum conductor size: 0.46" (11.8 mm). 

Accuracy: 

  • ±(3%+50mA), up to 1000A add 15%, up to 20kHz add 12%

i410 400Amp AC / DC Current Clamp ---

The i410 AC/DC Current Clamp allows multimeters to measure up to 400A DC.

  • Battery-powered Hall-effect clamp-on probe measures AC/DC current from 1A to 400A. 
  • Maximum conductor size: one 1.18" (30 mm) or two 0.98" (25 mm). 
  • Output: 1 mV per amp AC/DC. 
  • Accuracy: ± (3.5% + 0.5A), 1A to 400A, 45 Hz to 400 Hz.



i1010 600Amp AC / 1,000Amp DC Current Clamp ---

-------------

Battery-powered Hall-effect clamp-on probe measures ac current to 600A, dc current to 1000A. Output is 1 mV per amp dc or ac. Maximum conductor size: one 1.18" (30 mm) or two 0.98" (25 mm). 

Accuracy: 

  • ±(2%+0.5A), 1A to 1000A, 45Hz to 400Hz.
  • ±(3+0.5A), 1A to 600A, 400Hz to 2kHz sinewave.