Fluke Process Calibrators
Fluke 789 Process Meter ---
Ordering Info
Key new features:
-
24 V Loop power supply
-
HART mode setting with loop power (adds 250 ohm resistor)
-
100% larger dual display
-
1200 ohm drive capability on mA source
-
Enhanced backlight with two brightness settings
-
Improved battery performance (four AA batteries)
-
0-100% mA Span Check buttons to toggle between 4
and 20 mA
-
Infrared I/O serial port compatible with FlukeView®
Forms Software V 2.1 (available Feb. 2003)
-
Externally accessible battery for easy battery changes
Externally accessible fuses for easy replacement
787 features included in the 789:
-
DMM designed to meet 1000 volt IEC 1010 CAT III standards
-
Precision 1000 V, 440 mA True-rms digital multimeter
-
Measure ac and dc volts (0.05% dc current accuracy)
-
Frequency measurement to 20 kHz
-
Min/Max/Average/Hold/Relative modes
-
Diode Test and Continuity Beeper
-
Simultaneous mA and % of scale readout
-
20 mA dc current source / loop calibrator / simulator
-
Manual Step (100 %, 25 %, Coarse, Fine) plus Auto
Step and Auto Ramp
|
Includes:
TL71 premium test lead set
AC72 Alligator Clips
Four AA alkaline batteries
Users Manual
Product Overview
|
The Fluke 787 ProcessMeter was the first tool to combine a loop calibrator
with a DMM to give process technicians double the power in one tool. Now
it's even better – the ultimate loop calibration multimeter – the Fluke
789 ProcessMeter. The 789 has a display that's not only twice as
large, but also twice as bright with two levels of backlighting. With its
built-in, selectable 250 ohm HART resistor, it eliminates the need to carry
a separate resistor with you. Now process technicians can do a lot
more while carrying a lot less.
Fluke 787 Process Meter ---
|
-
DMM and loop calibrator in one tool
-
Precision 1000V, 440 mA digital multimeter
-
Measure ac and dc volts, ac and dc current, resistance, continuity, and
frequency
-
0.1% dc voltage accuracy
-
0.05% dc current accuracy, 1 ‘A resolution to 30 mA
-
Simultaneous mA and % of scale readout
-
True rms ac voltage measurement to 1 kHz
-
Frequency measurement to 20 kHz
-
Min/Max/Average/TouchHold/Relative modes
-
Diode test and continuity beeper
-
DC current source/loop calibrator
-
20 mA current source/simulator
-
Simultaneous mA and % of scale readout
-
Manual step (25%, coarse, fine) plus auto step and auto ramp
-
Clear LCD with backlight; 4,000 counts (30,000 counts for dc current)
-
Externally accessible battery for easy battery changes
-
1000V overload protection on V, ohms, frequency
-
150V overload protection on mA, backed-up by 440 mA 1000V fuse
-
Designed to meet 1000 volt IEC 1010 Cat III standards
|
The Fluke 787 ProcessMeterT puts a complete troubleshooting solution
in the palm of your hand. Get in touch with more information, faster and
easier with the newest member of the Fluke 80 Series, the 787 ProcessMeter.
The 787 gives you the measurement capabilities you expect from our rugged,
reliable DMMs plus the ability to source, simulate, or measure dc current
with 1 microamp resolution and accuracy of 0.05%. Put it all together
and you have the ideal tool for troubleshooting and calibrating current
loop applications. So if you're tired of always tracking down a calibrator,
lugging around two tools and switching back and forth, get the single best
solution for doubling your power. The 787 ProcessMeter from Fluke.
707
Loop Calibrator ---
-
Large display and simple, quick-click interface for
easy one-handed operation.
-
Simultaneous mA and % readout for quick, easy, interpretation
of readings.
-
mA accuracy of 0.015%, superior to other loop calibrators
in this price range.
-
1µA resolution for mA source, simulate and
measure.
-
Push button 25% steps for fast, easy linearity checks.
-
0-100% “span check” for fast confirmation of zero
and span.
-
Selectable slow ramp, fast ramp, and step ramp to
provide smooth outputs for valve slewing and loop functional tests.
-
24 volt internal loop supply, so you can power and
read a transmitter at the same time without carrying a DMM.
-
Measures V dc to 28 V.
-
Single 9 V battery that is easily changed.
-
0-20 mA or 4-20 mA default start up modes.
-
Innovative output adjustment dial with 1 µA
and 100 µA resolution.
-
HART™ mode connects 250 W resistor in series with
24 V loop for compatibility with HART communicators.
|
|
Fluke
707Ex Intrinsically Safe Loop Calibrator

|
ATEX Intrinsic Safe Certification for use in classified
areas.
The 707Ex is an intrinsically
safe loop calibrator for use in explosion endangered areas.
The Fluke 707Ex is certified
in accordance with the ATEX directive (Ex II 2 G Eex ia IIC T4) in Zones
1 and 2.
The 707Ex is also certified
to operate in accordance with Factory Mutual N.I. Class 1, Division 2 areas
Group A-D.
Ordering Info
|
-
Measure current
-
Measure current/Loop power
-
Measure voltage
-
Simulate current; manual adjust; scroll up/down
-
Simulate current; 25% steps; 0 - 100% steps
-
Simulate current; Auto ramp (smooth/step)
-
Source current; manual adjust; scroll up/down
-
Source current; 25% steps; 0 - 100% steps
-
Source current; Auto ramp (smooth/step)
Fluke 715 Volt /mA Calibrator ---
|
Features at a Glance
-
Measure loop current (0-20 mA, 4-20 mA) signals with 0.025% accuracy and
1 mA resolution
-
Measure voltage output process signals from PLCs, transmitters
-
Source or simulate 24 mA loop current
-
Source voltage to 100 mV or 10V
-
24V loop supply with simultaneous current measurement
|
Fluke 705 Loop Calibrator ---
|
For a powerful loop calibrator at a very affordable price, choose the
new Fluke 705 Loop Calibrator. This feature-rich solution to loop calibration,
maintenance and repair offers:
-
A large display and simple, pushbutton interface for ease of use.
-
Simultaneous mA and % readout for quick, easy interpretation of readings.
-
mA accuracy of 0.02%
-
Push button 25% steps for fast, easy linearity checks. Save time over traditional
knob type controls.
-
"Span Check" for fast confirmation of zero and span.
-
Selectable slow ramp, fast ramp, and step to provide smooth outputs for
valve slewing and loop functional tests.
-
24 volt internal loop supply, so you can power and read a transmitter at
the same time without carrying a DMM.
-
Single 9V battery that is easily changed.
-
0 - 20 mA or 4 - 20 mA default start up modes.
|
Fluke mA Process Clamp Meter
Troubleshoot 4-20mA without breaking the current loop
This innovative new Fluke-771 mA Clamp Meter is designed to measure, test and troubleshoot 4-20 mA control signals without breaking the mA loop. Make mA measurements in active control systems without disruption process control. Save time and money troubleshooting process control loops. |
|
|