Contact the closest office: 1-800-358-5525 |
|
![]() Available in compact 1/32 and 1/16 DIN panel sizes, the 2100 series uses advanced PID algorithms to give stable ‘straight line’ temperature control. Self tuning is included to optimize the control performance without the need for specialized knowledge or training. The operator interface can be customized to present only those parameters that an operator needs to see and adjust, while all other parameters are locked away under password protection. Heater failure can be detected when the controller is used with a TE10S Solid State Relay. Tactile buttons ensure positive operation. |
A universal input, employing patented Instant Accuracy™ technology,
allows selection of nine internally stored thermocouple types and the Pt100
resistance thermometer. Other input linearizations may be factory
downloaded. Linear inputs can be scaled to the desired display range.
Two outputs are configurable for heating, cooling or alarms. Three
internal alarm setpoints are provided, configurable as high, low or deviation
alarms. Alarms can be ‘blocked’ on start-up to prevent unnecessary operator
alerts.
An optional external output module can be ordered to convert the logic output to a relay. An external precision resistor input adapter can accept 4-20mA process inputs. Ramp-dwell programming
|
| Control modes:
Supply voltages:
Operating ambient: Inputs: Output ratings: |
PID or ON / OFF
85-264Vac, 5.0watts maximum
0-55°C, 0-90%RH non-condensing Nine standard thermocouple types. Pt100. 4-20mA linear. Custom input available 2 |
![]() Available in 1/16, 1/8 and 1/4 DIN panel sizes the 2200e series are
configurable for PID, On/ Off or motorized valve control for heat only
or heat/cool applications, satisfying both electrical and gas heating requirements.
Self-tuning and customized cooling algorithms are included to optimize
control performance. These units employ patented INSTANT ACCURACY™
technology on scaleable universal inputs accepting nine standard thermocouple
and RTD inputs, DC process inputs or downloadable custom inputs.
|
Modular heating and cooling outputs are provided, plus one or two alarm
relay outputs. The 1/8 and 1/4 DIN units have two digital inputs
to select auto/manual transfer, standby mode, second setpoint or alarm
acknowledge. The 1/4 DIN model 2204e has an additional 10 amp high
current output option.
Digital communications with Modbus® RTU or DeviceNet™ protocols are available for easy con- nection to PLC™ or PC based supervisory control and data logging systems. A simple ramp and hold profile can be programmed using the internal ramp generator and dwell timer. With custom cooling algorithms, these controllers are ideal for plastics extrusion. Eliminate ammeters using PDSIO® current monitoring facility. Heater current may be displayed and open and short circuit faults detected and alarmed.
|
| Control modes:
Supply voltages: Operating ambient: Inputs: Output ratings:
Communications: |
PID, ON / OFF or motorized valve control
85-264VAC, 10.0 watts maximum 0-55°C, 0-90%RH non-condensing Nine standard thermocouple types. Pt100. 4-20mA linear. Custom input available Relay: 2A, 264Vac resistive
Modbus®, ASCII, DeviceNet™ |
![]() The 2416 is a high stability programmable controller with an extensive range of options. Either PID, on/off or motorized valve control can be configured, for electrical and gas heating applications. Dual PID settings, advanced ‘one shot’ and continuously adaptive tuning are available. Programmer Functionality
|
The controller employs universal inputs with INSTANT ACCURACY™ and
accepts a range of plug-in modules for heating, cooling, analog retransmission,
second process value input and remote setpoint. High speed Modbus®
and ASCII communications provide easy connection to PLC™ or PC based supervisory
systems.
Multi-zone programming can be implemented using PDSIO® retransmission to deliver a master setpoint to one, two, or three client controllers, with holdback from any client if the temperature deviates from the setpoint by more than a set value. Up to four setpoint programs can be stored with 16 ramp-dwell segments and up to three event outputs. Eliminate ammeters using PDSIO® current monitoring facility. Heater
current may be displayed and open and short circuit faults detected.
|
| Control Modes:
Supply Voltages:
Operating Ambient: Panel Sealing: Communications: Inputs:
Output Ratings:
|
PID, On/Off or motorized valve control
85-264Vac, 15watts maximum
0-55°C, 0-90%RH non-condensing IP65, plug-in Modbus RTU, Ei-Bisynch ASCII Nine standard thermocouple types. Pt100. 4-20mA linear (1% sense resistor supplied, 0.1% 2.49 resistor available (order SUB2K/249R.1). Custom input available. Relay: 2A, 264Vac resistive
|
![]() Available in 1/16, 1/8 and 1/4 DIN panel sizes, the 2400 series are high stability controllers with an extensive range of options. Either PID, on/off or motorized valve control can be configured, satisfying both electrical and gas heating applications. Dual PID settings, advanced ‘one shot’ and continuously adaptive tuning are available to optimize control performance. The controllers employ universal inputs with Instant Accuracy™ and accept a range of plug-in modules for heating, cooling, analog retransmission, second process value input and remote setpoint. High speed Modbus® RTU, Profibus® DP, DeviceNet™, and Ei-Bisynch ASCII digital communications provide easy connection to PLC™, PC based supervisory control and data logging systems. |
Multi-zone programming can be implemented using PDSIO® retransmission
to deliver a master setpoint to one, two, or three client controllers,
with holdback from any client if the temperature deviates from the setpoint
by more than a set value. The 2408 and 2404 are available with Modbus®
RTU, Ei-Bisynch ASCII, or DeviceNet™ digital communications. The
2408f and 2404f models are available with Modbus® or Profibus®
DP digital communications.
One, four or 20 setpoint programs can be stored with 16 ramp-dwell segments and three or eight event outputs. Eliminate ammeters using PDSIO® current monitoring facility. Heater current may be displayed and open and short circuit faults detected. Ideal For:
|
| Control Modes:
Supply Voltages:
Operating Ambient: Panel Sealing: Communications: Inputs:
Output Ratings: |
PID, On/Off or motorized valve control
85-264Vac, 15watts maximum
0-55°C, 0-90%RH non-condensing IP65, plug-in Modbus® RTU, DeviceNet™, Profibus® DP, Ei_Bisynch ASCII Nine standard thermocouple types. Pt100. 4-20mA linear (1% sense resistor supplied, 0.1% 2.49 resistor available. Order SUB2K/249R.1). Custom input available Relay: 2A, 264Vac resistive
|
About... | Table of Contents | Manufacturer Index | What's New Send Inquiries to: |