Contact the closest office: 1-800-358-5525

  Eurotherm Controls 

Barber- Colman Industrial Controls 

2000 Series Indicators / Alarms

 2132i 1/32 DIN Compact Indicator and Alarm Unit
 2116i 1/16 DIN Compact Indicator and Alarm Unit
 2108i 1/8 DIN Horizontal Indicator and Alarm Unit
 2408i 1/8 DIN Horizontal Universal Indicator and Alarm Unit
 2216 FM 1/16 DIN Factory Mutual Approved Alarm Unit
 2208 FM 1/8 DIN Factory Mutual Approved Alarm Unit
 2204 FM 1/4 DIN Factory Mutual Approved Alarm Unit


Model 2132i and 2116i Indicator / Alarm Units --- 

Ideal For 

  • Temperature indication 
  • 4-20mA process inputs 
  • Over-temperature protection 
  • Process value trip unit 
  • Nema 4x, IP65 
The 2132i/2116i are compact high performance four digit units with large, bright green LEDs for measurement and display of temperature and other process variables in standard 1/32 and 1/16 DIN panel sizes. 
Both models include an optional alarm relay output and logic connection for either a second external alarm relay or alarm acknowledge input.

The universal input employing patented Instant Accuracy™ technology accepts a wide range of two wire temperature sensors and process inputs. 

An optional external output module can be ordered to convert the logic output to a relay.  An external precision resistor input adapter can accept 4-20mA process inputs.
 

Features: 

  • Universal input: covers a wide range of temperature and process inputs 
  • Three software alarm setpoints: separate warning and shut-down limits 
  • One or two alarm outputs: alarm alert and shut-down outputs 
  • Front panel configuration: easy, on-site set-up 
  • Wide-range: 85-264Vac, or 20-29Vac/dc supply can be installed world-wide 
  • Plug-in from front: rapid replacement, reducing downtime 
Display: 

Supply voltage:

Operating ambient: 

Panel Sealing:

Inputs: 

Sample rate:

Relay output rating:

Green four digit 10mm LED

 85-264Vac 20-29Vac/dc, 15watts maximum 

 0-55°C, 5-95%RH non-condensing 

 NEMA 4X, IP65, plug-in 

 nine standard thermocouple types, Pt100, Linear mV/mA 

 5Hz 

 2A, 264Vac resistive 


Model 2108i Indicator / Alarm Units --- 

The 2108i provides accurate four digit measurement and display of temperature and other process variables in a standard 1/8 DIN horizontal format. Two alarm relay outputs are provided from up to three internal soft alarms. External digital keylock and alarm acknowledge inputs are standard.

The 2108i employs patented Instant Accuracy™ technology and accepts outputs from all popular temperature, pressure, flow and level measurement sensors. 

Ideal For 

  • Temperature indication 
  • 4-20mA process inputs 
  • Over-temperature protection 
  • Process value trip unit 

Features: 

  • Universal input: covers a wide range of temperature and process inputs 
  • Two software alarm setpoints: for operator alert and plant protection 
  • Wide-range 85-264Vac, supply: can be installed world wide 
  • Plug-in from front: rapid replacement, reducing downtime 
  • Front panel configuration: easy, on-site set-up 
  • Tactile buttons: friendly operation 


 

Display: 

Supply voltage: 

Operating ambient: 

Panel Sealing: 

Inputs: 

Sample rate: 

Output ratings: 

Red or green four digit 15.9mm LED 

100–240Vac 15%, +10% 

0-55°C, 5-95%RH non-condensing 

IP65, plug-in 

nine standard thermocouple types, Pt100,Linear mV/mA 

5Hz 

Relay output rating: 2A, 264Vac resistive 


Model 2408i Universal Process Inidcator / Alarm Unit --- 

Accurate stable measurement of temperature, pressure, level, flow and other process variables are provided by the 2408i universal indicator.  An optional second process value input allows the average, difference, minimum or maximum of two values to be displayed. 
  Temperature linearization functions for nine thermocouple types and Pt100 resistance thermometers are selectable.   Other input linearizations can be factory downloaded. 

Strain gauge and presssure sensor inputs can be energized from an internal 5 or 10Vdc supply.  An automatic calibration routine is provided to remove zero and span offsets.
 
 

For flow measurements, square root extraction is available as standard.

The 2408i employs patented Instant Accuracy™ technology in its universal input.  Large bright red or green displays ensure good visibility in high or low ambient lighting conditions.

Features: 

  • Four alarm setpoints: for alert and plant protection 
  • Serial communications: for supervisory control and data acquisition 
  • DC retransmission: fully isolated retransmission to remote control and monitoring equipment 
  • Second PV input: for monitoring auxiliary signals 
  • Strain guage input: for pressure monitoring 
Ideal For: 
  • Temperature indication 
  • Pressure, flow and level monitoring 
  • Differential measurement 
  • Process protection/monitoring 
  • Strain gauge input 


Factory Mutual (FM) Approved Alarm Units --- 

The Model 2216e is an accurate indicator and alarm unit with one, FM compliant, alarm relay output fitted as standard.  It has two optional outputs 1 and 2. Output 2 can be fitted with a second FM alarm relay. Output 1 can be fitted with either: dc retransmission of PV, an additional alarm relay output, or an alarm acknowledge input.  A communications option is also available.

The 2208e and 2204e FM alarm units have two FM compliant, alarm relay outputs fitted as standard. In addition they has two optional outputs 1 and 2.  Output 1 can be fitted with either: dc retransmission of PV, an additional alarm relay output, or an alarm acknowledgement input.  Output 2 can be fitted with an additional, non–FM compliant alarm relay output.  A communications option is also available.  The FM compliant relay outputs are configurable as absolute high or low alarms.  They are fixed as latching alarms, de-energised in the alarm state.  It is not possible to configure them otherwise. 


Universal Input 
A universal input circuit employing patented Instant Accuracy™ technology with an advanced analog to digital convertor samples the input and continuously corrects it for drift. This gives high stability and rapid response to process changes. High noise immunity is achieved by rejection of 50/60Hz pick-up and other sources of noise. The input covers all thermocouple types, Pt100 RTD linear millivolts or milliamps or DC volts. Input filtering from 1.0 to 999.9 seconds is included.

Features: 

  • Standard 1/4, 1/8, 1/16. 1/32 DIN panel cutout 
  • Independent alarm outputs 
  • Customized operator interface 
  • Digital input for alarm reset 
  • Modbus RTU Communications 
  • Plug-in from the front 
  • Simple front panel acknowledgment and reset of alarms 
  • FM approved operation 
  • Compliant with European EMC and low voltage safety directives 
  • IP65/NEMA 4x 

  •  


About...  |  Table of Contents  | Manufacturer Index  | What's New

Send Inquiries to:

Copyright © 2009 Davis Instruments. All rights reserved.