Dixson Nuclear Qualified Bargraph Indicators
AMETEK Dixson “PRO” (PROgrammable) Series bargraphs are the preferred choice
for new applications, or for replacement of switchboard meters, other common
size indicators, and setpoint controllers. The “PRO” Series is feature-enhanced,
and options are available to solve most common application problems.
Our nuclear-qualified bargraphs carry Class I (1E) or Class II (seismic
only) levels of qualification for all control room applications.
Class I (1E)
Includes all safety-related control loops and their various components
(models SA101P, SA202P, SH101P, SH202P, SN101P, and SN202P).
Class II (seismic only)
Includes all instruments mounted in close proximity to any Class I component.
If a component becomes detached from its mounting such that it could fall
onto Class I components, then that component must meet the requirements
of a Class II component (models BA101P, BA202P, BH101P, BH202P, BN101,
and BN202P).
Features:
(These are the same as our commercial application
Pro-Series models but with nuclear ratings.)
-
Mild-environment qualification to IEEE-323-1983
and IEEE-344-1987
-
QA programs include 10CFR50, Appendix B, audited
by a member of NUPIC
-
Single and dual bar models
-
Top of the line “Pro Series”
-
HI, LO, ALARM annunciators and three programmable
set points
-
Form C control relays
-
RS-422 communication
-
Programmable from front panel or PC serial
link
-
88,000-hour MTBF
Nuclear Rated Bargraphs
 |
Features
-
Mild-environment qualification to IEEE-323-1983 and IEEE-344-1987
-
QA programs include 10CFR50, Appendix B, audited by a member of NUPIC
-
Brilliant red LED display for excellent visibility
-
Minimum 88,000-hour MTBF
-
Rugged--high resistance to vibration and shock
-
Microprocessor-based design
-
Programmable configuration via front panel switches or PC serial link
-
Available with or without program switches on front*
-
Input signal ranges switch-selectable
-
Auto-calibration algorithm
-
Input signal linearization
-
Accurate square root extraction
-
Min/max signal memory
-
High resolution and accuracy
-
Single and dual models
-
Sizes interchangeable with most major manufacturers and panel cutouts
-
Front panel mounting (except SH202P)
-
Underrange/overrange indication
-
Modular design for flexibility and options
Options
-
Digital display, reading to ±10 percent underrange/overrange
-
Green or amber LEDs
-
On/off control via three setpoint relays**
-
Direct temperature measurement*
-
Auxiliary transducer power supply*
-
Two-wire, isolated retransmission, 4 to 20 mA*
-
RS-422 serial communication*
|
|