Contact the closest office: 1-800-358-5525

 

Ashcroft Pressure Instruments

Handheld LCD Digital Calibrator Type ATE-100 Pressure, Temperature, Voltage and Current Measurement

  • Easily interchangeable "Quick Select"® pressure and temperature modules 
  • Dual Display - simultaneous measurement and display of pressure, temperature, voltage or current in any combination 
  • Pressure measurement accuracies of ±0.025%, 0.05% and 0.10% FS 
  • Pressure ranges from 0.25" H2O to 10,000 psi. 
  • Also measures temperature: supports most standard RTD probes and thermocouples 
  • Min/max, tare, flow, leak, programmable damping, percent function, RS232 output, battery check, switch test function, display hold, mA & Vdc measurement capability... all standard
  • Field calibration capability 
The Ashcroft ATE-100 is a measurement and calibration system with a vast array of capabilities. These capabilities extend far beyond those of precision pressure measurement.  The base unit contains a wide variety of application-specific firmware as well as the ability to measure both current and voltage inputs.  In addition, this unit has the ability to interface the system with a computer, data acquisition system or dumb terminal via the standard RS232 interface.


LCD Digital Indicator Type ST-2A Pressure, Temperature, Voltage and Current Measurement

Buy It Now !  Ordering Info

  • Dual Display - simultaneous measurement and display of pressure, temperature, voltage or current in any combination 
  • Pressure measurement accuracies of ±0.025%, 0.05% and 0.1% FS 
  • Pressure ranges from 0.25" H2O to 10,000 psi 
  • Easily interchangeable "Quick Select"® pressure and temperature modules 
  • Multiple engineering units - 12 User-defined engineering units - 1 
  • Temperature measurement with most standard RTDs and thermocouples 
  • Programmable damping 
  • Tare capability 
  • Display hold 
  • RS232 two-way communications 
  • Standard NIST-traceable certificate of calibration 
  • Field recalibration capability 
The ST-2A is the perfect bench companion product to the Ashcroft ATE-100 field handheld calibrator.  This bench top (or panel mounting) package shares the same pressure and temperature modules and interfaces with the same software packages as the Ashcroft ATE-100.  An intuitive, menu-driven user interface puts all of the ST-2A's power at the simple press of a key.  It uses the AQS (Ashcroft Quick-Select™) modular sensor system to provide the ultimate in measurement flexibility.


Pressure Tester Dual Display LCD Digital Pressure Indicator

Buy It Now !  Ordering Info

  • Can hold 2 sensors and display both readings simultaneously 
  • Ranges: 0.25" H20 to 10,000 psi 
  • Accuracies from 0.1 to 0.025% FS 
  • Push-button zero adjust 
  • Max/min memory 
  • Selectable engineering units 
  • Variable damping 
  • Tare 
  • Port select 
  • Push-to-print 
  • RS232 I/O 
  • Field calibration capability 
The Ashcroft PT indicator is an extremely versatile pressure measurement and test instrument.  It can simultaneously display the output of two pressure sensors, two RTD's or one of each.  It offers 12 standard user-selectable engineering units and one custom value.  Other dedicated front panel buttons make it easy to set zero, check max/min values, adjust measurement damping, select either or both ports for standard display, additive or differential display, print the display and configure the RS232 output.  All front panel features are accessible via the RS232 port for remote configuration or data acquisition.


Volume Controller Type AVC-1000 & 3000

Ashcroft® precision-pressure volume controllers provide a quick-and-easy method for precisely setting a pressure in a closed pneumatic system. They are ideal for use with Ashcroft Type 1082 Test Gauges for the calibration of other pressure-measurement and control devices.

The AVC unit consists of a volume chamber with an internal piston assembly. The piston seals across the diameter of the chamber. Once the AVC unit is connected to a pneumatic system, the volume of the chamber becomes part of the volume of the system.

The pressure-adjust knob at the front of the unit repositions the piston within the chamber through interaction with a precision-machined lead screw. Piston movement within the chamber increases or decreases the volume of the system, depending on the direction of movement. In a closed system where gas cannot leak out upon compression or be drawn in upon expansion, this volume change results in a change in the internal pressure. Increasing the volume by moving the piston toward the front of the AVC unit will decrease the pressure.
 

Conversely, decreasing the volume by moving the piston toward the rear of the unit will increase the pressure. The pressure change generated by a given amount of piston travel is proportional to the change in volume as compared to the total system volume.

AVC units are available for pressures up to 3000 psi. The AVC-1000 can be used to set pressures from vacuum through 1000 psi while the AVC-3000 can be used for pressures from vacuum through 3000 psi.

An integral balance valve provides a means for equalizing pressure on both sides of the piston prior to making the final adjustments when setting the pressure. This minimizes the resistance encountered when repositioning the piston and assures ease of pressure setting, even at 3000 psi. The balance valve also serves as a pressure-relief valve, assuring that the differential pressure across the piston does not reach unsafe levels.

AVC units can also be used without a compressed air source for the generation of moderate levels of positive pressure and vacuum. The high resolution of the AVC, combined with the ability to generate pressure and vacuum, make it an ideal tool for low-pressure (below 1 psi) calibration and test as well as higher pressure calibration and test activities.


About...  |  Table of Contents  | Manufacturer Index  | What's New

Send Inquiries to:

Copyright © 2009 Davis Instruments. All rights reserved.