Amprobe Digital Clamp-On
Meters
ACD-10 Series Digital
Clamp-On Multimeters
ACD-10 Pro
* ACD-10 TRMS Pro
* ACD-14
Ordering Info
|
FEATURES
-
AC and DC Voltage to
600V
-
AC Current to 400A
-
Resistance to 40MOhm
with Continuity Buzzer
-
Capacitance to 3000µF
-
Frequency measurement
-
Diode test
-
Hold and Maximum reading
functions
-
Accommodates conductors
up to 1.02” (26mm) in diameter
-
Auto Ranging
-
Auto power off and low
battery indication
-
Rubber over-molded case
-
Overload protected
|
SPECIFICATIONS
AC Voltage:
4.000V, 40.00V, 400.0V, 600V ±(1.5% Rdg + 5 LSD)
@ 4.000V, 40.00V, 400.0V**
DC Voltage:
0-400.0mV, 4.000V, 40.00V, 400.0V, 600V ±(0.5% Rdg
+ 3 LSD) @ 4.000V, 40.00V, 400.0V**
AC Current:
0-40.00A, 400.0A ±(1.9% Rdg + 8 LSD)**
Resistance with
Continuity Buzzer: 0-400.0Ohm,
4.000kOhm, 40.00kOhm, 400.0kOhm, 0-4.000MOhm, 40.00MOhm ±(0.6% Rdg
+ 4 LSD) @ 4.000kOhm, 40.00kOhm, 400.0kOhm**
Capacitance:
500.0nF, 5.000µF, 50.00µF, 500.00µF, 3000µF
±(3.5% Rdg + 6 LSD)
Frequency (Using
Jaw or Test Leads):
ACD-10:
40-400Hz with Jaw, 10Hz to 2kHz with test leads ±(0.5% Rdg + 4 LSD)
ACD-14:
5Hz - 100kHz ±(0.5% Rdg + 4 LSD)
TRMS measurement:
(ACD-10 TRMS Pro Only)
Temperature (Type-K)
: (ACD-14 Only) - 4°F to 572°F
(-20°C to 300°C) ±(2.0% Rdg + 6°F)
ACD-330T Digital AC
Clamp-On Multimeters
ACD-330T ---
|
FEATURES
-
TRMS sensing
-
Dynamic Min/Max/Avg
Recording
-
In-rush Peak Current
capture (1mS response)
-
Dual Display of Frequency
with Current or Voltage
-
Continuity Buzzer and
Diode Test
-
Reading Hold function
-
Maximum jaw opening
2.04" (52mm)
-
Auto/Manual ranging
-
Auto power off
-
Low Battery indicator
-
Overload protection
on all ranges
|
SPECIFICATIONS:
AC/DC
Voltage: 0-399.9, 1000V
±(1% Rdg + 3 LSD)
AC Current:
0-399.9, 1000A ±(1.5% Rdg + 3 LSD)
Resistance:
0-399.9, 4000 Ohm ±(3% Rdg + 5 LSD) @ 65-400Hz,
400-700A
Continuity Buzzer:
<10.0 Ohm ±(3.5% Rdg + 6 LSD)
Frequency Measurements:
10.00-99.99Hz, 1000.0Hz ±(0.2% Rdg + 4 LSD)
ACD-11 AC Clamp Ons
--
|
FEATURES
-
AC Volts to 600
-
AC Amps to 1000
-
Ohms to 40K
-
Continuity Buzzer
-
Maximum jaw opening
2.14" (54.5 mm)
-
Reading Hold function
-
Auto Ranging
|
SPECIFICATIONS
AC Voltage:
0-400.0, 600V ±(1.2% Rdg + 3 LSD)
AC Current:
0-400.0, 1000A ±(2% Rdg + 5 LSD) @0-400.0A±(2.5%
Rdg + 5 LSD) @ 400.0 - 1000A
Resistance:
200-4000 Ohm, 4.00k-40.00 kOhm ±(2% Rdg + 5 LSD)
@ 200 Ohm - 40.00 kOhm
Continuity Buzzer:
<100 Ohm ±(3.5% Rdg + 6 LSD)
ACDC-620T Digital AC/DC
Clamp-On Multimeter --
|
FEATURES
-
TRMS Measurement
-
Dynamic Min/Max/Avg.
Recording function
-
In-rush Peak Current
capture (1 mS response)
-
Temperature measurement
-
Dual Display of °F
& °C readings
-
Continuity Buzzer
-
Reading Hold function
-
Auto/Manual Ranging
-
Auto power off
-
Maximum jaw opening
2.04" (52mm)
-
Low Battery & Over-range
Indicators
-
Analog Bar Graph indicator
-
CATIII-600V
|
SPECIFICATIONS
AC/DC Voltage:
0-399.9, 1000V ±(1% Rdg + 3 LSD) @ 0-1000VDC**
±(1.5%
Rdg + 3 LSD) @45-400Hz, 0-1000VAC**
AC/DC Current:
0-399.9, 1000A ±(1.5% Rdg + 3 LSD) @0-400A DC**
±(2%
Rdg + 5 LSD) @ 45-65Hz, 40-400A AC**
Resistance:
0-399.9?, 4.000 kOhm, ±(1% Rdg + 3 LSD)
Capacitance:
0-399.9, 4000µF ±(3% Rdg + 4 LSD) @ 0-400µF**
Temperature:
-40°F to 2500°F (-40°C to 1372°C) ±(0.5%
Rdg + 6°F) (±0.5% Rdg + 3°C)
In-rush Peak
Current Max (AC or DC): 0-399.9,
1000A ±(2% Rdg + 43 LSD)
Continuity Buzzer:
<10.0 Ohm
Diode Test:
1.65mA/< 3.3V
Analog Rotary Scale
Clamp-On Multimeters
RS-1
* RS-3 * RS-3 Super
* RS-1007
Ordering Info
|
FEATURES
-
Works in wide range
of temperatures
-
Does not need battery
for measuring volts or amp
-
Easy to use rotary scale
-
Pointer lock
-
Recessed magnifying
window
-
Drop Proof to 5ft
|
| |
RS-1
|
RS-3
|
RS-3 Super
|
RS-1007
|
| AC Voltage: |
0-150 / 600V
±3% of full scale
|
0-150 / 300 / 600V
±3% of full scale
|
0-150 / 300 / 600V
±3% of full scale
|
0-150 / 300 / 750V
±3% of full scale
|
| AC Current: |
0-6 /15 /40 /100A
±3% of full scale
|
0-6 /15 /40 /100 /300A
±3% of full scale
|
0-6 /15
/40 /100 /300A
±3% of full scale
|
0-15 /40 /100 /300 /1000A
±3% of full scale
|
| Resistance: |
N / A
|
25 Ohm Midscale
±3% of arc
|
25 Ohm Midscale
±3% of arc
|
25 Ohm Midscale
±3% of arc
|
| Frequency: |
60Hz
±3% of full scale
|
60Hz
±3% of full scale
|
50-400Hz
±3% of full scale
|
60Hz
±3% of full scale
|
| Jaw Opening: |
1"
|
1"
|
1"
|
2"
|
Testmaster Kits
TM-43A * TM-43A Super * TM-63 * TM-63 Super
-
Clamp-On Meter
-
RS-3 with TM-43A and TM-63
-
RS-3 Super with TM-43A Super and TM-63 Super
-
Carrying Case
-
Model C with TM-43A Kits
-
Model AR with TM63 Kits
-
VLK-411R Extendo Test Leads
-
A-47L Line Splitter
-
VRC-320 Alligator Clips
-
OHB-3HE Ohmeter adapter
-
PSA-1 Phase Sequence Adapter in TM-43A
Kits
-
A50-1 Current Transformer in TM-43A Kits
|
Testmaster kits with
convenient carrying cases
|
Analog Flat Scale AC
Clamp-On Multimeter
FS-3L ---
|
FEATURES
-
AC Volts to 600
-
AC Amps to 300
-
Ohms to 100,000
-
Temperature (with optional
probe) to 225°F
-
Pointer lock
-
1" Diameter Jaw
-
Calibrated for use on
50 or 60Hz systems
-
Taut Band meter movement
-
Drop proof to 5ft
|
AC Volts:
0-150
/300 /600V ±3% of full scale
AC Amps:
6
/15 /40 /100 /300A ±3% of full scale
Resistance:
0-1000 Ohm, 0 - 100 000 Ohm ±3% arc
Temperature:
-25 to 225°F
|