Contact the closest office: 1-800-358-5525

 

Action Instruments Ultra SlimPak II®

WebView Signal Conditioners -- Buy It Now !  Ordering Info

High quality products begin with a high quality, tightly controlled process.  Process signals need to be as error free as possible.  You should expect your process instrumentation to do more than just eliminate ground loops.  The WebView I/O series brings a new level of accuracy, functionality and ease of use to process instrumentation. 

The WV Series is the best signal conditioner family ever produced by Action Instruments.  Besides being as great signal conditioner, as a bonus, you can view your process data, or perform diagnostic checks over your company's intranet, with the optional WVC16 I/O Communications Interface.  With the Interface, email notification can be generated when signals are out of range.  Plus, the WV Series modules store the min/max temperature value as well as the current internal temperature of the module.  If scheduled calibration is required, a built-in timer can be programmed to notify the user when it is time for calibration checks.

WebView -- Traditional signal conditioners with some not so traditional features:

  • The Best Input/Output Accuracy and Stability Available
    • Input Accuracy of 0.015%
    • Output Accuracy of 0.05%
    • Stability of 100ppm
  • Field Configurable
  • Integral Diagnostic Capability
  • Versatile Alarm Capabilities
  • Can Provide E-mail Notification when Problems Occur

With Optional Ethernet Communications: 

  • View Process Data over your Intranet
  • Works with Internet Explorer or Netscape, No Special Software Necessary
  • A Timer will Notify User when it is time for Routine Maintenance
  • Store Min/Max Internal Temperature Values for Diagnostics 

WVC16 Communications Interface

  • Interface with up to 32 Signal Conditioning Modules
  • No Programming Required
  • Battery Backed Data

The Ultra SlimPak II Communications Interface adds functionality never before found in a signal conditioning system. A single WVC16 interfaces with as many as 32 Ultra SlimPak II devices by means of an internal infrared communications link. Through an Ethernet link in the WVC16, the information can then made available over the user's intranet. This powerful combination allows the user to view process data on a near real time basis, perform data logging functions on specified modules, view diagnostic information, and (under certain conditions) calibrate the modules remotely.

The WVC16 can send email messages to people who might need to be notified when an alarm condition exists. It can also send an email message letting maintenance personnel know when it's time to perform calibration checks. All of this functionality is made possible by a signed Java applet which is (transparently) downloaded to run on the client's computer. Using an applet rather than a traditional web page allows data to be updated in near real time. The applet provides access to the signal conditioner's data, which includes:

  • Module configuration summary
  • Module configuration editing
  • Diagnostic/warning status
  • Alarm setup & status
  • E-mail setup, editing & address book
  • Process variable viewing
  • Data logging capabilities

All memory to support the signal conditioner's historical data is battery backed. The web pages and all email messages are stored in non-volatile memory.

_____

The WV Series is the best signal conditioner family ever produced by Action Instruments. Besides being as great signal conditioner, as a bonus, you can view your process data, or perform diagnostic checks over your company's intranet, with the optional WVC16 I/O Communications Interface. With the Interface, email notification can be generated when signals are out of range. Plus, the WV Series modules store the min/max temperature value as well as the current internal temperature of the module. If scheduled calibration is required, a built-in timer can be programmed to notify the user when it is time for calibration checks.  

Smart Power

Smart Power adjusts the output voltage and current, depending on the power output required to drive the current load. A low impedance current loop will subsequently use less power than a high impedance current loop. Previous designs provide only a single supply at the highest voltage required to drive the highest impedance load. Smart Power can save as much as 1/2 Watt per unit and reduce the operating temperature as well.

Enhanced Diagnostic LEDs

Blinking LEDs communicate the following information:

GREEN

  • 2Hz when the input is under range
  • 8Hz when the input is over range
RED:
  • 2Hz when the output is under range
  • 8Hz when the output is over range

Configuration

In addition to the DIP switches and pushbutton, it is possible to remotely configure each module, using an Ethernet connection to the WVC16 and a remote PC-based web browser.

Integral Diagnostics

Besides the four diagnostic LED's, further diagnostic information can be obtained using a computer. All Ultra SlimPak II units can provide HI/LO and overtemperature soft alarms when used with a WVC16 communications interface.


Action Instruments Ultra SlimPak II® WebView Series Signal Conditioner Selection Guide

Input Selection Typical Application Description
Model
DC Voltage or Current
(V, mV, A, mA)
Voltage/current scaling, isolation, noise reduction and signal drive DC Input Field Configurable Isolator
DC motor/current limit, level/position control, Hi/Lo pressure alarm, power demand 2-channel comparitor DC Input Field Configurable Limit Alarm
RTD
(Types Pt, Ni, Cu)
Temperature control, monitoring and data acquisition RTD Input Field Configurable Isolator
Heater/cooler control, Hi/Lo temperature alarm, motor temperature monitor RTD Input Field Configurable Limit Alarm
Thermocouple
(Types E, J, K, R, S, T, B)
Temperature control, monitoring, and data acquisition Thermocouple Input Field Configurable Isolator
Heater/cooler control, Hi/Lo temperature alarm, motor temperature monitor Thermocouple Input Field Configurable Limit Alarm
Potentiometer 
(0-100 ohm to 0-100K ohm)
Tank level control, monitoring, data acquisition, resistance position sensor conditioning Potentiometer Input Field Configurable Signal Conditioner

Strain Gauge 
(± 5mV, ± 10mV, ±20mV, ± 50mV, ±100mV, ± 200mV input )

1 to 10V 120mA excitation

Pressure control, pressure status monitoring, weight, load cell conditioning and data acquisition Bridge Input Field Configurable Isolator
AC Voltage or Current
(V, mV, A, mA)
Voltage/current scaling, power monitoring, isolation, buffering AC Input Field Configurable Isolator
AC motor/current limit, AC power status monitor AC Input Field Configurable Limit Alarm
Frequency
(0-10KHz)
Flow/velocity control or monitoring, motor speed control, scaling, pulse accumulation, integration totalizing Frequency Input Field Configurable Isolator
24 Volt DC Power Supplies Supply 24VDC power to 2, 3, and 4-wire transmitters 24VDC, 500mA
24VDC, 200mA
24VDC, 1.0A
24VDC, 2.3A

DC Input Field Configurable Isolator

WV408

Provides a fully isolated DC output signal in proportion to a DC input
  • Lower Power Requirements with Smart Power Control

  • Improved Accuracy

  • LED Trip and Input Indicators

  • Optional E-mail Notification of Alarms



Buy It Now !  Ordering Info
The The Ultra SlimPak II model WV408 has both voltage and current input ranges. Four voltage input ranges (±150mV, ±1.5V, ±15V and ±150V) are DIP switch selectable. Each of these ranges has at least 95% zero and span adjustment, which, for example, would allow you to set a 0-20mV user range on the ±150mV full scale range. Two current input ranges (±2.5mA and ±25mA) are also DIP switch selectable. "Sigma- Delta" conversion produces an effective resolution of 15 bits. Both voltage and current have input accuracies of 0.015% of full scale. Outputs include 0-10V, 0-20mA and 4-20mA. The WV408 also supports reverse output.

RTD Input Field Configurable Isolator

WV418

Provides a fully isolated DC output signal in proportion to a RTD input
  • Lower Power Requirements with Smart Power Control

  • Improved Accuracy

  • Optional E-mail Notification of Alarms

  • DIP Switch Configuration

  • Supports 2, 3 or 4 Wire RTD's

The The Ultra SlimPak II model WV418 supports 2-wire, 3-wire or 4-wire Pt100 RTDs with alphas of either 0.00385 or 0.00392, as well as Cu10. Ranges are DIP switch selectable or optionally PC programmable. Outputs include 0-10V, 0-20mA and 4-20mA.

Thermocouple Input Field Configurable Isolator

WV428

Provides a fully isolated DC output signal in proportion to a Thermocouple input
  • Lower Power Requirements with Smart Power Control

  • Improved Accuracy

  • Optional E-mail Notification of Alarms

  • DIP Switch Configuration

The The Ultra SlimPak II model WV428 supports B, C, E, J, K, N, R, S & T thermocouples that are DIP switch selectable. The WV428 also supports a millivolt range of -20 to +80mVDC. The input accuracy of the WV428 is 0.05% with a CJC error of ±1°C. Both voltage and current have an input accuracy of 0.015% of full scale. Outputs include 0-10V, 0-20mA and 4-20mA.

Potentiometer Input Field Configurable Isolator

WV438

Provides a fully isolated DC output signal in proportion to a Potentiometer input
  • Lower Power Requirements with Smart Power Control

  • Improved Accuracy

  • Optional E-mail Notification of Alarms

  • DIP Switch Configuration

The The Ultra SlimPak II model WV438 is a potentiometer input signal conditioner supporting 3-wire potentiometers and slidewire devices from 100 ohms to 100k ohms. The switch selectable output ranges are 0-10VDC,0- 20mA and 4-20mA. All of the output ranges are fully adjustable via pushbutton calibration. The input default range is 0 to 100% of the potentiometer range, but can be adjusted via pushbutton calibration to any 20% portion of the potentiometer. The default output range is 4-20mA.

Strain Gage Input Field Configurable Isolator

WV448

Provides a fully isolated DC output signal in proportion to a Strain Gage (Bridge) input
  • Lower Power Requirements with Smart Power Control

  • Improved Accuracy

  • Optional E-mail Notification of Alarms

  • DIP Switch Configuration

The The Ultra SlimPak II model WV448 is a bridge input signal conditioner supporting three-wire input full scale ranges of ±5mV to ±200mV, (default is ±50mV). The switch selectable output ranges are 0-10VDC, 0-20mA and 4-20mA. All the input and output ranges are fully adjustable via pushbutton calibration. The default output range is 4-20mA.

AC Voltage or Current Input Field Configurable Isolator

WV468

Provides a fully isolated DC output signal in proportion to an AC Voltage or Current input
  • Lower Power Requirements with Smart Power Control

  • Improved Accuracy

  • Optional E-mail Notification of Alarms

  • DIP Switch Configuration

The The Ultra SlimPak II model WV468 has both voltage and current input ranges. Eight AC voltage input ranges (50mV, 150mV, 500mV, 5V, 20V, 50V, 150V & 250V) are DIP switch selectable. Each of these ranges has at least 95% zero and span adjustment. Two AC current input ranges (20mA and 100mA) are also available. Outputs include 0-10V, 0-20mA and 4-20mA. The WV468 also supports reverse output mode.

Frequency Input Field Configurable Isolator

WV478

Provides a fully isolated DC output signal in proportion to an AC Voltage or Current input
  • Lower Power Requirements with Smart Power Control

  • Improved Accuracy

  • Optional E-mail Notification of Alarms

  • DIP Switch Configuration

The The Ultra SlimPak II model WV478 accepts a frequency of up to 10kHz, with a minimum input span of 2Hz. The input amplitude can range from 150mVp to 150Vrms.

DC Voltage or Current Input Field Configurable Limit Alarm

WV108

Features:

  • Dual Setpoints, 2 SPDT Relay Outputs

  • Improved Accuracy

  • Optional E-mail Notification of Alarms

  • DIP Switch Configuration

The The Ultra SlimPak II model WV108 is a DC Voltage or Current Input Limit Alarm with dual setpoints and two contact closure outputs. The input type and alarm functions are field configurable, offering maximum flexibility. There are five input voltage ranges between ±20mV and ±200V, and two current input ranges, ±10mA and ±100mA. Alarm setpoints are fully adjustable throughout the entire range.

The WV108-2000 contains two standard non-latching SPDT relays. When power is removed, the relays revert to their non-powered state. The WV108-2001 contains two latching relays. Whatever position the relays are in when power is removed is where they will remain when power is re-applied (a reset switch is provided to reset the relays after the alarm is no longer true). Both models are configurable as a single or dual setpoint alarm, with HI or LO trips. The WV108-2000 supports failsafe or non-failsafe operation. In failsafe operation the relay coil is energized when the process is below the HI setpoint or above the LO setpoint (opposite for non-failsafe). In the failsafe mode, a power failure results in an alarm state output.


RTD Input Field Configurable Limit Alarm

WV118

Features:

  • Programmable HI or LO, Failsafe or Non-failsafe

  • Improved Accuracy

  • Adjustable Deadband

  • LED Trip and Input Indicators

  • Optional E-mail Notification of Alarms

The The Ultra SlimPak II model WV118 is an RTD Limit Alarm with dual setpoints and two contact closure outputs. The input type and alarm functions are field configurable, offering maximum flexibility. The WV118 supports Pt100, in both 0.00385 and 0.00392 alphas, and Cu10 RTDs. All ranges allow the setpoints to be fully adjustable throughout the entire range.

The WV118-2000 contains two standard non-latching SPDT relays. When power is removed, the relays revert to their non-powered state. The WV118-2001 contains two latching relays. Whatever position the relays are in when power is removed is where they will remain when power is re-applied (a reset switch is provided to reset the relays after the alarm is no longer true). Both models are configurable as a single or dual setpoint alarm, with HI or LO trips. The WV118-2000 supports failsafe or non-failsafe operation. In failsafe operation the relay coil is energized when the process is below the HI setpoint or above the LO setpoint (opposite for non-failsafe). In the failsafe mode, a power failure results in an alarm state output.

Operation
Each of the alarm setpoints has a respective HI or LO deadband. Red LEDs will illuminate indicating an alarm condition. The trip will reset only when the process falls below the HI deadband or rises above the LO deadband. (The WV118-2001 requires pressing the reset switch in order to reset the relay after being tripped.) The deadband can be left at the minimum level (the factory default) or can be set to whatever level is desired.


Thermocouple Input Field Configurable Limit Alarm

WV128

Features:

  • Programmable HI or LO, Failsafe or Non-failsafe

  • Improved Accuracy

  • Adjustable Deadband

  • LED Trip and Input Indicators

  • Optional E-mail Notification of Alarms

The The Ultra SlimPak II model WV128 is a Thermocouple Input Limit Alarm with dual setpoints and two contact closure outputs. The input type and alarm functions are field configurable, offering maximum flexibility. There are seven thermocouple types (B, E, J, K, R, S and T) from which to choose. Alarm setpoints are fully adjustable throughout the entire range.

The WV128-2000 contains two standard non-latching SPDT relays. When power is removed, the relays revert to their non-powered state. The WV128-2001 contains two latching relays. Whatever position the relays are in when power is removed is where they will remain when power is re-applied (a reset switch is provided to reset the relays after the alarm is no longer true). Both models are configurable as a single or dual setpoint alarm, with HI or LO trips. The WV128-2000 supports failsafe or non-failsafe operation. In failsafe operation the relay coil is energized when the process is below the HI setpoint or above the LO setpoint (opposite for non-failsafe). In the failsafe mode, a power failure results in an alarm state output.

Operation
Each of the alarm setpoints has a respective HI or LO deadband. Red LEDs will illuminate indicating an alarm condition. The trip will reset only when the process falls below the HI deadband or rises above the LO deadband. (The WV128-2001 requires pressing the reset switch in order to reset the relays after being tripped.) The deadband can be left at the minimum level (the factory default) or can be set to whatever level is desired.


AC Voltage or Current Input Field Configurable Limit Alarm

WV168

Features:

  • Programmable HI or LO, Failsafe or Non-failsafe

  • Improved Accuracy

  • Adjustable Deadband

  • LED Trip and Input Indicators

  • Optional E-mail Notification of Alarms

The The Ultra SlimPak II model WV168 is an AC Voltage or Current Input Limit Alarm with dual setpoints and two contact closure outputs. The input type and alarm functions are field configurable, offering maximum flexibility. There are eight input voltage ranges between 50mV and 250V, and two current input ranges, 20mA and 100mA. Alarm setpoints are fully adjustable throughout the entire range.

The WV168-2000 contains two standard non-latching SPDT relays. When power is removed, the relays revert to their non-powered state. The WV168-2001 contains two latching relays. Whatever position the relays are in when power is removed is where they will remain when power is re-applied (a reset switch is provided to reset the relays after the alarm is no longer true). Both models are configurable as a single or dual setpoint alarm, with HI or LO trips. The WV168-2000 supports failsafe or non-failsafe operation. In failsafe operation the relay coil is energized when the process is below the HI setpoint or above the LO setpoint (opposite for non-failsafe). In the failsafe mode, a power failure results in an alarm state output.

Operation
Each of the alarm setpoints has a respective HI or LO deadband. Red LEDs will illuminate indicating an alarm condition. The trip will reset only when the process falls below the HI deadband or rises above the LO deadband. (The WV168-2001 requires pressing the reset switch in order to reset the relay after being tripped.) The deadband can be left at the minimum level (the factory default) or can be set to whatever level is desired.


DIN-Rail Mount Power Supplies

G905, H902, H910, H915

  • Material: Aluminum Alloy 5052H32, 0.063" thick 
  • Anodized: Black, MIL-A-8625
Model G905, H902, H910 and H915 power supplies can be used to operate most 24 VDC instruments including Action's Ultra SlimPak® and the ActionI/QTM. All models convert 110VAC to 24VDC. 

The G905, with the EG12 case, is ideal for use in high density or limited space installations.

Model H902 supplies up to 200mA at 24VDC, the G905 supplies up to 500mA at 24VDC, the H910 supplies up to 1000mA at 24VDC and the H915 supplies up to 2300mA at 24VDC.  All models feature an LED power indicator and multiple wire terminal connections (except on the H910). The H902, H910 and H915 offer input fuse protection. The output section for each model features DC short circuit protection. The G905 input is varistor protected.