Contact the closest office: 1-800-358-5525 |
|
|
|||
| Input Selection | Typical Application | Description | Model |
| DC Voltage or Current
(V, mV, A, mA) |
Voltage/current scaling, isolation, noise reduction and signal drive | DC Input Field Configurable Isolator | G408 |
| DC motor/current limit, level/position control, Hi/Lo pressure alarm, power demand 2-channel comparitor | DC Input Field Configurable Limit Alarm | G108 | |
| RTD
(Types Pt, Ni, Cu) |
Temperature control, monitoring and data acquisition | RTD Input Field Configurable Isolator | G418 |
| Heater/cooler control, Hi/Lo temperature alarm, motor temperature monitor | RTD Input Field Configurable Limit Alarm | G118 | |
| Thermocouple
(Types E, J, K, R, S, T, B) |
Temperature control, monitoring, and data acquisition | Thermocouple Input Field Configurable Isolator | G428 |
| Heater/cooler control, Hi/Lo temperature alarm, motor temperature monitor | Thermocouple Input Field Configurable Limit Alarm | G128 | |
| Potentiometer
(0-100 ohm to 0-100K ohm) |
Tank level control, monitoring, data acquisition, resistance position sensor conditioning | Potentiometer Input Field Configurable Signal Conditioner | G438 |
| Strain
Gauge
(0.5, 1, 3, 5, 10, 20, 50mV/V) 1 to 10V adjustable excitation |
Pressure control, pressure status monitoring, weight, load cell conditioning and data acquisition | Bridge Input Field Configurable Isolator | G448 |
| AC Voltage or Current
(V, mV, A, mA) |
Voltage/current scaling, power monitoring, isolation, buffering | AC Input Field Configurable Isolator | G468 |
| AC motor/current limit, AC power status monitor | AC Input Field Configurable Limit Alarm | G168 | |
| Frequency
(0-2Hz to 0-10KHz) |
Flow/velocity control or monitoring, motor speed control, scaling, pulse accumulation, integration totalizing | Frequency Input Field Configurable Isolator | G478 |
| 24 Volt DC Power Supplies | Supply 24VDC power to 2, 3, and 4-wire transmitters | 24VDC, 500mA | G905 |
| 24VDC, 200mA | H902 | ||
| 24VDC, 1.0A | H910 | ||
| 24VDC, 2.3A | H915 | ||
| Field Configurable
Flexibility
Action Instruments has pioneered wide ranging, field configurable instrument design for over 10 years. The Ultra SlimPak Series is a result of this effort and investment. It utilizes the latest ASIC and microprocessor based technologies to provide 1800VDC isolation and wide ranging adjustments for easy, accurate, discrete signal conditioning. The power supply of the Ultra SlimPak will accept any AC or DC source between 9 and 30VDC, typically a 12 or 24VDC supply is used. The value of a field configurable instrument is that it allows the user to easily set the instrument for their specific or even custom I/O range. This flexibility can reduce spare parts inventory or increase the efficiency of the process by maximizing resolution in critical process measurements. Ultra High
Density
Limit Alarms
Alarms are indicators of problems — be they production line faults, process upsets, equipment failures or control system abnormalities. Limit Alarms safe guard industrial facilities and workers by alerting and informing process personnel of abnormal conditions Ultra SlimPak G1X8 Series of Limit
Alarms
Setpoint
Flexibility
These features provide the flexibility required to solve many diverse process control applications with additional benefits such as reduced spare parts inventory and the convenience of an off the shelf solution. Signal
Conditioners
Ultra SlimPak G4X8 Series of Conditioners
ASIC
Reliability - Lifetime Warranty
|
DC Input Field Configurable IsolatorG408 |
|
Provides a fully
isolated DC output signal in proportion
to a DC input
|
![]() Ordering Info |
| The Ultra
SlimPak® model G408 is a DIN rail mount,
DC voltage or current input signal conditioner with 1800VDC isolation
between
input, output and power. The field configurable input and output offer
flexible, wide ranging capability for DC current and voltage ranges.
Input
voltage spans from 10mV to 100V and input current from 1mA to 100mA.
The
G408 is CSA and UL certified, and CE Mark compliant.
|
|
DC Input Limit Alarm Ultra SlimPak®G108 |
|
Provides relay
contact closure(s) at a preset DC input
level
|
![]() Ordering Info |
| The Ultra
SlimPak® model G108 is a DIN rail mount,
DC voltage or current input limit alarm with dual setpoints and two
contact
closure outputs. The field configurable input and alarm functions offer
flexible setpoint capability. Input voltage spans from 10mV to 200V and
input current from 1mA to 100mA. Bipolar inputs are also accepted. The
G108 is CSA and UL certified, and CE Mark compliant.
|
|
RTD Input Field Configurable IsolatorG418 |
|
|
![]() Ordering Info |
| The Ultra
SlimPak® model G418 is a DIN rail mount,
RTD input signal conditioner with 1800VDC isolation between input,
output
and power. The field configurable input and output offer flexible, wide
ranging capability for platinum and copper RTDs. The input can be
configured
for any of up to 16 temperature ranges. Output is linear to input
temperature
and can be set for any of 5 DC current and voltage ranges. The G418 is
CSA and UL certified, and CE Mark compliant.
|
|
RTD Input Limit AlarmG118 |
|
Provides relay
contact closure(s) at a preset RTD/Resistance
input level
|
![]() Ordering Info |
| The Ultra
SlimPak® model G118 is a DIN rail mount,
RTD input limit alarm with dual setpoints and two contact closure
outputs.
The field configurable input and alarm functions offer flexible
setpoint
capability. There are up to eight temperature ranges available for each
RTD type to ensure accuracy and maximize setpoint resolution. The G118
is CSA and UL certified, and CE Mark compliant.
|
|
Thermocouple Input, Field Configurable IsolatorG428 |
|
Provides
an Isolated, Linearized DC Output
in Proportion to a Thermocouple Input
|
![]() Ordering Info |
|
The G428 is a
DIN rail mount, thermocouple input
signal conditioner with 1800VDC isolation between input, output and
power.
The field configurable input and output offer flexible, wide ranging
capability
for J, K, T, R, S, E and B type thermocouples.
The input of
the G428 can be configured for over
60 different thermocouple temperature ranges (see Table 6). The output
is linear to temperature and can be set for either 0-5V, 0-10V, 0-1mA,
0-20mA or 4-20mA.
For an RTD and
thermocouple input temperature transmitter
with improved accuracy and stability, see Action I/Q model Q488. PC or
DIP switch programmable.
Wide ranging,
precision zero and span pots allow
50% adjustablity of offset and span turn-down within each of the
ranges.
For example, the 0-1000°C range could be offset and turned down to
provide a 4-20mA signal representing 500-1000°C. Similarly,
adjustment
can be referenced to the output range. The example from above could be
used to provide a 12-20mA signal from a 750 to 1000°C temperature
input.
|
|
Thermocouple Input Limit AlarmG128 |
|
Provides relay
contact closure(s) at a preset temperature
input level
|
![]() Ordering Info |
| The Ultra
SlimPak® model G128 is a DIN rail mount,
thermocouple input limit alarm with input terminal cold junction
compensation
(CJC), dual setpoints and two contact closure outputs. The field
configurable
input and alarm functions offer flexible setpoint capability. There are
up to six temperature ranges available for each thermocouple type to
ensure
accuracy and maximize setpoint resolution. A bipolar input switch is
provided
for temperatures below 0°C. The G128 is CSA and UL certified, and
CE
Mark compliant.
|
|
Potentiometer Input, Field Configurable Signal ConditionerG438 |
|
Provides
a DC Output in Proportion to
a Potentiometer Input
|
![]() Ordering Info |
|
The Ultra
SlimPak G438 is a DIN rail mount, potentiometer
input signal conditioner with 1800VDC isolation between DC power and
the
input/output circuitry. The input provides a constant voltage and is
designed
to accept any three-wire potentiometer from 100W to 100KW. The field
configurable
output is switch selectable providing either 0-5V, 0-10V, 0-1mA, 0-20mA
or 4-20mA DC signal.
Wide ranging,
precision zero and span pots, used
in conjunction with DIP switches, allow 80% adjustablity of offset and
gain to transmit a full scale output from any 20% portion of the
potentiometer
input.
|
|
Bridge Input, Field Configurable Signal ConditionerG448 |
|
Provides
an Isolated DC Output in Proportion
to a Bridge/Strain-Gauge Input
|
![]() Ordering Info |
|
The Ultra
SlimPak G448 is a DIN rail mount, bridge
or strain-gage input signal conditioner with 1800VDC isolation between
input, output and power. The field configurable input and output offers
flexible, wide ranging capability for bridge or strain-gage input
applications
from 0.5mV/V to over 50mV/V.
Wide ranging,
precision zero and span pots allow
50% adjustablity of offset and gain within each of the 11 switch
selectable
input ranges. The output can be set for either 0-5V, 0-10V, 0-1mA,
0-20mA
or 4-20mA.
This
flexibility, combined with an adjustable (1
to 10VDC) bridge excitation source, provides the user a reliable,
accurate
instrument to isolate and condition virtually any bridge or strain-gage
input.
|
|
AC Input, Field Configurable IsolatorG468 |
|
Provides
an Isolated DC output in Proportion
to an AC Input
|
![]() Ordering Info |
|
The field
configurable G468 is a DIN rail mount,
AC input signal conditioner with 1800VDC isolation between input,
output
and power. The field configurable input and output offers flexible,
wide
ranging capability for scaling, converting or buffering AC inputs
ranging
from 5mA to 100mAAC or 50mV to 250VAC.
For current
inputs above 100mAAC, it is recommended
that an input shunt resistor be used and the G468 be configured for the
proper input range. For example, a 5AAC current transformer output can
use the Action model C006 shunt resistor (0.1W, 5W) and set the input
of
the G468 for 0-500mVAC.
The DC output
of the G468 is proportional to the
average of the fully-rectified AC input signal, and is calibrated for
sine
waves between 40-400Hz.
|
|
AC Input Limit AlarmG168 |
|
Provides relay
contact closure(s) at a preset AC input
level
|
![]() Ordering Info |
| The Ultra
SlimPak® model G168 is a DIN rail mount,
AC input limit alarm with dual setpoints and two contact closure
outputs.
The field configurable input and alarm functions offer flexible
setpoint
capability. Input voltage spans from 100mV to 250VAC and input current
from 10mA to 100mAAC. The G168 is CSA and UL certified, and CE Mark
compliant.
|
|
Frequency Input, Field Configurable IsolatorG478 |
|
Provides an Isolated DC Output
in Proportion to input Frequency
|
![]() Ordering Info |
|
The Ultra
SlimPak Model G478 is a DIN rail mount,
frequency input signal conditioner with 1800VDC isolation between
input,
output and power. The field configurable input and output offer
flexible,
wide ranging capability for variable frequency drives, magnetic
pick-ups,
turbine flow meters, and other pulse or frequency output transducers.
The input of
the G478 can be configured for any frequency
span from 2Hz to 10,000Hz. The input amplitude threshold sensitivity
can
be adjusted from 150mVp to 10Vp to ensure accurate frequency
measurement
and minimize transient noise related errors. The maximum input
amplitude
is 150 Vrms. The output can be set for either 0-5V, 0-10V, 0-1mA,
0-20mA
or 4-20mA.
Advanced
digital technology allows the G478 to be
field configured for virtually any frequency input to DC signal output
within the ranges specified. Calibration utilizes ‘Touch-Cal’
technology
where the user simply applies the minimum and maximum input
frequencies,
touching a recessed button to configure the corresponding minimum and
maximum
output range.
The very narrow
Ultra SlimPak housing enables installations
of up to 24 unit per linear foot. The wide ranging power supply is
inverter
isolated and accepts any voltage between 9 and 30VDC.
|
|
About... | Table of Contents | Manufacturer Index | What's New Send Inquiries to: |